MARATHON PIPE LINE LLC

hazardous_liquid Incident — — January 29, 2025

Incident Information

Incident DateJanuary 29, 2025
OperatorMARATHON PIPE LINE LLC
CommodityREFINED AND/OR PETROLEUM PRODUCT (NON-HVL) WHICH IS A LIQUID
Pipeline Typehazardous_liquid

Location

State
Coordinates40.67634, -81.34791

Cause

CauseEQUIPMENT FAILURE
SubcausePUMP OR PUMP-RELATED EQUIPMENT

Casualties

Fatalities0
Injuries0

Costs

Property Damage$7,500
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

"EAST SPARTA UNIT 6 SHUT DOWN UPON GENERATION OF A PUMP SEAL FAILURE ALARM. UNIT WAS ISOLATED AND DRAINED. MPL AND THE MANUFACTURER ARE INVESTIGATING THE CAUSE OF THE FAILURE. SEAL MATERIALS STATIONARY FACE: SILICON CARBIDE ROTATING FACE: CARBON SUPPLEMENTAL FINAL UPDATE: THE SEAL FAILURE WAS CAUSED BY A FAILURE IN THE PIN MECHANISM DESIGNED TO HOLD THE PRIMARY STATIONARY FACE IN PLACE, ALLOWING IT TO SHIFT AND BECOME MISALIGNED WITHIN THE LOCK RING. THIS MISALIGNMENT LED TO LOSS OF FLUID FILM, EXCESSIVE WEAR/HEAT, AND EVENTUAL LEAKAGE. TO PREVENT RECURRENCE, THE LOCKING MECHANISM WILL BE REDESIGNED TO SECURE THE STATIONARY FACE, AND ALL MECHANICAL SEALS FROM THIS MANUFACTURER ARE BEING REVIEWED FOR SIMILAR DESIGN FLAWS, TRACKED FOR PERFORMANCE, AND MONITORED FOR MEAN TIME BETWEEN FAILURES."