"MAGELLAN PIPELINE COMPANY, LP"
hazardous_liquid Incident — — February 13, 2025
Incident Information
| Incident Date | February 13, 2025 |
| Operator | "MAGELLAN PIPELINE COMPANY, LP" |
| Commodity | HVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 39.12855, -94.60428 |
Cause
| Cause | NATURAL FORCE DAMAGE |
| Subcause | TEMPERATURE |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | $250 |
| Emergency Response | $0 |
| Other Costs | $0 |
Location Map
Incident Narrative
"ON FEBRUARY 13TH,2025 AT APPROXIMATELY 10:00 AM OPERATIONS RECEIVED AN ALARM FROM PHILLIPS (HAZ GAS). LOCAL TECHNICIAN WENT TO PHILLIPS AND OBSERVED BUTANE VAPORING OFF A SIGHT GLASS. THE TECHNICIAN WAS ABLE TO ISOLATE THE SIGHT GLASS AND INSTALL A NEW PIECE OF GLASS AND GASKET. UPON FURTHER EXAMINATION IT WAS DETERMINED THAT MOISTURE HAD DEVELOPED INSIDE OF THE SIGHT GLASS AND HAD BECOME FROZEN AND CAUSED THE GLASS TO CRACK."