PHILLIPS 66 PIPELINE LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorPHILLIPS 66 PIPELINE LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.99172, -93.98660

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

DURING ROUTINE OPERATOR ROUNDS, COMPANY PERSONNEL DISCOVERED A RELEASE FROM A PUMP SEAL ON A REGULATED PUMP. THE PUMP WAS NOT RUNNING AT THE TIME OF THE DISCOVERY AND THEREFORE THE RELEASE WAS CONTAINED WITHIN THE PUMP BASIN AND SURROUNDING AREA. ALL PRODUCT WAS CONTAINED ON OPERATOR-CONTROLLED PROPERTY. AFTER DISCOVERY, THE OPERATOR WHO DISCOVERED THE RELEASE NOTIFIED ALL NECESSARY COMPANY PERSONNEL AND SUPERVISION. ON-SITE CONTRACTORS AND COMPANY PERSONNEL IMMEDIATELY INITIATED CLEAN-UP/REMEDIATION ACTIVITIES. AFTER A FAILURE ANALYSIS WAS PERFORMED IT WAS DETERMINED THAT THE FAILURE WAS CAUSED BY ABNORMAL WEAR DUE TO FREQUENT STARTUP AND SHUT DOWN CYCLES. THIS IS A MULTI-USE PUMP THAT IS NOT DEDICATED TO DOT OPERATIONS.