ONEOK NGL PIPELINE, LLC
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | ONEOK NGL PIPELINE, LLC |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 29.84539, -94.90882 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
ON 08/02/2023 AT 0600 A ONEOK OPERATOR NOTIFIED THE ONEOK MONT BELVIEU STORAGE OPERATIONS CONTROL ROOM OF A LEAK ON FILTER VESSEL 7001 AT ONEOK'S WEST WINFREE SITE. OPERATIONS RESPONDED TO THE LOCATION AND NATURAL GASOLINE WAS OBSERVED LEAKING FROM THE VESSEL CLOSURE. ALL LIQUID WAS CAPTURED IN A SECONDARY CONTAINMENT LOCATED UNDER THE CLOSURE. THE VESSEL WAS ISOLATED AND DE-INVENTORIED. THE SEALING ELEMENT ON THE VESSEL APPEARED TO BE THE CAUSE OF THE LEAK AND WAS REPLACED; THE VESSEL WAS SUBSEQUENTLY RETURNED TO SERVICE. UPDATE: ONEOK SUBMITTED THE FAILED SEALING ELEMENT AS WELL AS SEVERAL SAMPLES FROM INVENTORY TO A THIRD-PARTY LAB FOR ANALYSIS. THE THIRD-PARTY ANALYSIS DETERMINED THAT THE FAILURE OF THE SEALING ELEMENT APPEARS TO BE RELATED TO GAS-LIQUID EXPANSION RESULTING IN INTERNAL TEARS AND BLISTERS. NO SIGNS OF CHEMICAL DEGRADATION WERE IDENTIFIED WITHIN THE SEALS PROVIDED. ONEOK HAS VERIFIED THAT THE FAILED SEALING ELEMENT WAS INSTALLED PER MANUFACTURER RECOMMENDATIONS.
About This Pipeline Incident
Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.