"MEDALLION OPERATING COMPANY, LLC"
hazardous_liquid Incident, , January 26, 2026
Incident Information
| Incident Date | January 26, 2026 |
| Operator | "MEDALLION OPERATING COMPANY, LLC" |
| Commodity | CRUDE OIL |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 31.43856, -102.36126 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | PUMP OR PUMP-RELATED EQUIPMENT |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | $3,000 |
| Emergency Response | $0 |
| Other Costs | $0 |
Location Map
Incident Narrative
"AT APPROXIMATELY 11:36 AM, PCC RECEIVED AN ALARM FOR BOOSTER PUMP 12331 AT CRANE, INDICATING A HI-HI LEVEL CONDITION IN THE PUMP SEAL POT. UPON NOTIFICATION THE STATION WAS IMMEDIATELY SHUT DOWN, AND NOTIFICATIONS WERE MADE TO LOCAL OPERATING PERSONNEL AND MANAGEMENT. ONCE ON-SITE PERSONNEL PERFORMED LOTO PROCEDURES, ISOLATED THE PUMP, AND INSTALLED SKILLET BLINDS ON THE SUCTION AND DISCHARGE LINES. FIELD PERSONNEL IDENTIFIED A FAILED PUMP SEAL AND AFTER FURTHER INVESTIGATION IT WAS DETERMINED INTERNAL PUMP COMPONENTS REQUIRED REPLACEMENT. MANAGEMENT CONTRACTED ODESSA PUMP TO FABRICATE A REPLACEMENT PUMP FOR INSTALLATION THE FOLLOWING DAY. THE NEW PUMP WAS INSTALLED AND NORMAL OPERATIONS RESUMED."
About This Pipeline Incident
Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.