MAGELLAN PIPELINE COMPANY, LP

hazardous_liquid Incident —

Incident Information

Report Date
OperatorMAGELLAN PIPELINE COMPANY, LP
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates32.06422, -96.86353

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON FEBRUARY 5TH, 2024 AT 10:15 OPERATIONS PERSONNEL CONDUCTING DAILY FACILITY INSPECTIONS FOUND PRODUCT COMING FROM A 2"" BALL VALVE ON THE STRAINER DRAIN LINE ON THE ORION WEST PIPELINE IN FROST STATION. THE PIPELINE WAS SHUT DOWN, THE RELEASE LOCATION WAS ISOLATED, AND CLEAN-UP ACTIVITIES WERE INITIATED. FURTHER INVESTIGATION FOUND THAT THE SPLIT BODY STYLE VALVE HAD A GASKET FAILURE RESULTING IN THE RELEASE. TO PREVENT A REOCCURRENCE, THE VALVE WAS REPLACED. AFTER THE VALVE WAS REPLACED, THE LINE WAS RETURNED TO SERVICE.