HILAND CRUDE, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorHILAND CRUDE, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates48.25639, -103.72874

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

A DISCHARGE SWEDGE FAILED DUE TO A HAIRLINE CRACK ON A 20 HP PUMP AT THE CHORD OWNED OM ERICKSON 7-6 RESULTING IN 3.3 BBLS OF CRUDE OIL RELEASED ONTO THE LEASE SITE. UPON INVESTIGATION, IT WAS DETERMINED THAT PRODUCER OWNED LACT UNIT STRAINER WAS CLOGGED, RESULTING IN CAVITATION OF KM PUMPS LEADING TO VIBRATION THAT CRACKED THE SWEDGE. CLEAN-UP IS ONGOING.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in