KINDER MORGAN LIQUID TERMINALS, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorKINDER MORGAN LIQUID TERMINALS, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.72951, -95.21876

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON MAY 25TH, 2024 AT 10:35 CST, KMLT RECEIVED A SCADA ALARM IMMEDIATELY AFTER STARTING UP PUMP 3065. THE CONTROLLER IMMEDIATELY SHUT DOWN THE SYSTEM AND ISOLATED THE TANK. AT 10:36 CST A CREW LEADER IN THE AREA CONFIRMED THAT THE SIGHT GLASS ON THE 2"" MAINTENANCE START UP AND SHUT DOWN SYSTEM, WAS LEAKING INTO CONCRETE CONTAINMENT. THE AREA WAS CLEANED VIA A SUMP PUMP AND THE SIGHT GLASS WAS REMOVED AND AIR GAPPED. THE COMPONENT HAS BEEN REPLACED. ROOT CAUSE INVESTIGATION DID NOT YIELD A DETERMINING FACTOR FOR THE FAILURE AT THE SIGHT GLASS.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in