CENEX PIPELINE LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorCENEX PIPELINE LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates48.22885, -101.36906

Cause

CauseOTHER ACCIDENT CAUSE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Incident Narrative

ON JUNE 19, 2024 AT APPROXIMATELY 11:34 A.M., FIELD PERSONNEL WERE ON-SITE MONITORING A RECENTLY INSTALLED VIBRATION SENSOR WHEN A 1"" DIAMETER SCHEDULE 80 PIPE USED FOR THERMAL RELIEF OFF THE DISCHARGE SIDE OF MAINLINE PUMP UNIT 403 RUPTURED. FIELD PERSONNEL WITNESSED THE PIPE VIBRATING WHEN THE PUMPS WERE SHUTDOWN, RESULTING IN THE RELEASE AND IMMEDIATELY NOTIFIED THE CONTROL ROOM AND NOTIFIED A CENEX PIPELINE QI. SINCE THE SEGMENT WAS ALREADY SHUTDOWN, THE CONTROLLER FURTHER ISOLATED THE SEGMENT BY CLOSING THE NEAREST UPSTREAM AND DOWNSTREAM REMOTELY OPERATED VALVES. THERE WAS APPROXIMATELY 1 BARREL OF DIESEL RELEASED WHICH WAS CAPTURED FOR DISPOSAL. CENEX PIPELINE NOTIFIED THE NORTH DAKOTA DEPARTMENT OF ENVIRONMENTAL QUALITY OF THIS EVENT. CORRECTIVE ACTIONS TO ADDRESS THE FINDINGS OF THE INCIDENT INVESTIGATION WILL BE IMPLEMENTED UPON COMPLETION OF ANALYSIS THAT IS PRESENTLY UNDERWAY.