EXXONMOBIL PIPELINE COMPANY LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorEXXONMOBIL PIPELINE COMPANY LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.34896, -94.93969

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

THE TRAP DOOR WAS REPLACED WITH A NEWLY DESIGNED ENCLOSURE ON AUGUST 28TH, 2024, AND THE TRAP WAS RECOMMISSIONED ON SEPTEMBER 19TH, 2024. UPDATES MADE TO THIS REPORT: -UPDATED TOTAL COSTS -UPDATED THIS NARRATIVE ABOVE INCIDENT SUMMARY: ON TUESDAY, JULY 30, 2024, A CREW ARRIVED ONSITE TO REMOVE A CLEANING PIG FROM THE SCRAPER TRAP DOOR AT THE TEXAS CITY SCRAPER TRAP SITE. (IN ACCORDANCE WITH A 3RD PARTY LEASE AGREEMENT). THE CREW COMPLETED LOTO/DRAIN-UP, OPENED THE TRAP DOOR, INSTALLED A NEW O-RING PER PROCEDURES, AND CLOSED THE TRAP DOOR. THE LINE WAS RESTARTED ON JULY 31ST PER SCHEDULE AND A THIRD-PARTY OPERATOR IDENTIFIED THAT THE TRAP DOOR, WHICH IS LOCATED WITHIN A THIRD-PARTY FACILITY, WAS LEAKING. THE LINE WAS IMMEDIATELY SHUTDOWN AFTER IDENTIFICATION. THE RELEASE WAS CONTAINED ALL ONSITE AND CLEANED UP. ROOT CAUSE: THE SCRAPER TRAP DOOR PINCHED/STRESSED THE O-RING AT THE 12 O'CLOCK POSITION CAUSING FAILURE OF THE SEAL AND RELEASE OF CRUDE OIL. CONTRIBUTING FACTORS: O-RING POSITION ON THREADS INCREASES LIKELIHOOD OF DAMAGE DURING DOOR CLOSURE. PREVENTING RE-OCCURRENCE: THE SCRAPER TRAP DOOR WAS REPLACED ON AUGUST 28TH, 2024, WITH A NEW TRAP DOOR THAT WILL REDUCE THE LIKELIHOOD OF A PINCHED O-RING DURING CLOSURE.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in