WILLIAMS GAS PIPELINE - TRANSCO

gas_transmission Incident — — October 19, 2010

Incident Information

Incident DateOctober 19, 2010
OperatorWILLIAMS GAS PIPELINE - TRANSCO
CommodityNATURAL GAS
Pipeline Typegas_transmission

Location

State
Coordinates29.48842, -90.97753

Cause

CauseMATERIAL FAILURE OF PIPE OR WELD
SubcauseORIGINAL MANUFACTURING-RELATED (NOT GIRTH WELD OR OTHER WELDS FORMED IN THE FIELD)

Casualties

Fatalities0
Injuries0

Costs

Property Damage$350,000
Emergency Response$5,000
Other Costs$0

Location Map

Incident Narrative

PIPE WAS EXCAVATED AND EXAMINED ON NOVEMBER 7TH AND 8TH OF 2011. A LACK OF FUSION MANUFACTURING ANOMALY WAS LOCATED IN THE CENTER OF THE ERW LONG SEAM. THE LENGTH OF THE ANOMALY WAS FOUND TO BE 0.45 INCHES. A 24"" PRESSURE CONTAINING TYPE ""B"" STEEL SLEEVE, CENTERED AT THE ANOMALY LOCATION WAS INSTALLED AS A PERMANENT REPAIR.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.