NORTHWEST PIPELINE CORP (WGP)

gas_transmission Incident — — April 27, 2011

Incident Information

Incident DateApril 27, 2011
OperatorNORTHWEST PIPELINE CORP (WGP)
CommodityNATURAL GAS
Pipeline Typegas_transmission

Location

State
Coordinates42.62764, -111.83791

Cause

CauseEQUIPMENT FAILURE
SubcauseTHREADED CONNECTION/COUPLING FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$81,000
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

WILLIAMS (NORTHWEST PIPELINE) IDENTIFIED A 2"" THREADED TAP VALVE THAT WAS NOT SEALING PROPERLY DURING REGULAR MAINTENANCE. THE 2"" PIPELINE COMES OFF OF THE 22"" MAINLINE IN IDAHO STATE AND FEEDS A SINGLE HOME. AFTER ANALYZING THE SITUATION, WILLIAMS FEELS THAT THE BEST APPROACH IS TO REMOVE THE 2"" TAP VALVE. TO ACCOMPLISH THIS TASK, WILLIAMS ISOLATE THE SEGMENT OF 22"" MAINLINE PIPE, BLEW DOWN THE MAINLINE, ISOLATE THE 2"" PIPELINE AND CUT OUT THE SECTION OF MAINLINE THAT CONTAINS THE 2"" TAP. INSTEAD OF A SMALL PUP TO ACCOMODATE THE CUT OUT, A FULL JOINT OF NEW 22"" PIPE WAS INSTALLED IN THE MAINLINE TO ELIMINATE THREE COMPOSITE SLEEVES FOUND DURING THE EXCAVATION OF THE PIPE WHILE THE PIPE WAS OUT OF SERVICE. THE CUSTOMER WAS TRANSFERED ONTO ANOTHER AVAILABLE SERVICE.