TEXAS EASTERN TRANSMISSION LP (SPECTRA ENERGY CORP)

gas_transmission Incident — — April 19, 2012

Incident Information

Incident DateApril 19, 2012
OperatorTEXAS EASTERN TRANSMISSION LP (SPECTRA ENERGY CORP)
CommodityNATURAL GAS
Pipeline Typegas_transmission

Location

State
Coordinates28.43850, -93.45000

Cause

CauseCORROSION FAILURE
SubcauseINTERNAL CORROSION

Casualties

Fatalities0
Injuries0

Costs

Property Damage$300,000
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

BUBBLES WERE OBSERVED BY THE PISCES ENERGY PLATFORM OPERATORS ON APRIL 19, 2012. DIVERS DISCOVERED A PINHOLE LEAK IN THE TEXAS EASTERN 20-INCH LINE 41-A-6 WHICH WAS CAUSED BY INTERNAL CORROSION. TWO LEAK CLAMPS WERE INSTALLED AND THE PIPELINE WAS RETURNED TO FULL SERVICE ON MAY 8, 2012.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in