DOMINION ENERGY OHIO

gas_transmission Incident — — March 19, 2023

Incident Information

Incident DateMarch 19, 2023
OperatorDOMINION ENERGY OHIO
CommodityNATURAL GAS
Pipeline Typegas_transmission

Location

State
Coordinates40.86456, -81.46246

Cause

CauseCORROSION FAILURE
SubcauseINTERNAL CORROSION

Casualties

Fatalities0
Injuries0

Costs

Property Damage$117,000
Emergency Response$0
Other Costs$31,500

Location Map

Incident Narrative

"THE FINAL LABORATORY ANALYSIS REPORT FROM DNV INDICATES THAT THE LEAK OCCURRED ON THE UPSTREAM GIRTH WELD ON THE ELBOW SIDE DUE TO INTERNAL CORROSION. THE CORROSION WAS CONCENTRATED AT THE ELBOW FITTING AT THE HEAT AFFECTED ZONE OF THE GIRTH WELD. EVIDENCE INDICATES THERE WAS A CONDUCTIVE ENVIRONMENT AT THE ELBOW FITTING GIRTH WELD DUE TO THE POTENTIAL FOR WATER TO ACCUMULATE, LOW PH, AND HIGH CHLORIDES."