ENERGY TRANSFER COMPANY

gas_transmission Incident — — April 8, 2025

Incident Information

Incident DateApril 8, 2025
OperatorENERGY TRANSFER COMPANY
CommodityNATURAL GAS
Pipeline Typegas_transmission

Location

State
Coordinates28.83275, -98.14965

Cause

CauseCORROSION FAILURE
SubcauseINTERNAL CORROSION

Casualties

Fatalities0
Injuries0

Costs

Property Damage$170,000
Emergency Response$4,800
Other Costs$0

Location Map

Incident Narrative

"ON APRIL 8, 2025, ENERGY TRANSFER (ET) PERSONNEL DETECTED A FIRE WHILE ON ET SITE NEAR THE 97 DEHY TO COY CITY PIPELINE AT 14:30. OPERATIONS BEGAN TO TAKE PRECAUTIONARY MEASURES AND COMPLETELY ISOLATED THE LINE AT 15:15 AND THE FIRE WAS ALLOWED TO BURN OUT. ET PERSONNEL CONFIRMED DISCOVERY ON APRIL 9TH AT 10:30 AND DETERMINED THAT THE INCIDENT WOULD EXCEED THE COST REPORTING THRESHOLD. THE LINE HAS BEEN REPAIRED AND WAS RETURNED TO SERVICE AT 23:47 ON APRIL 11TH, 2025. THE CAUSE OF THE INCIDENT IS CURRENTLY UNKNOWN, AND THE INVESTIGATION IS UNDERWAY. THE LAB ANALYSIS DETERMINED THAT THE RUPTURE WAS THE RESULT OF INTERNAL CORROSION CAUSED BY STRESS-ORIENTED HYDROGEN INDUCED CORROSION (SOHIC). TO PREVENT THIS FROM OCCURRING IN THE FUTURE, THE MAOP OF THE PIPELINE WILL BE LOWERED AND THE CORROSION INHIBITOR PROGRAM WILL BE EVALUATED FOR EFFECTIVENESS AGAINST H2S CORROSION."