PECO ENERGY CO
gas_distribution Incident — BROOKHAVEN, PA — April 25, 2011
Incident Information
| Incident Date | April 25, 2011 |
| Operator | PECO ENERGY CO |
| Commodity | NATURAL GAS |
| Pipeline Type | gas_distribution |
Location
| City | BROOKHAVEN |
| State | PA |
| County | DELAWARE |
| Coordinates | 39.85474, -75.39189 |
Cause
| Cause | INCORRECT OPERATION |
| Subcause | DAMAGE BY OPERATOR OR OPERATOR'S CONTRACTOR NOT RELATED TO EXCAVATION AND NOT DUE TO MOTORIZED VEHICLE/EQUIPMENT DAMAGE |
Casualties
| Fatalities | 0 |
| Injuries | 1 |
Costs
| Property Damage | $0 |
| Emergency Response | $0 |
| Other Costs | $0 |
Location Map
Incident Narrative
"ON APRIL 25, 2011, A PECO GAS CONSTRUCTION AND MAINTENANCE CREW WAS REPAIRING A LEVEL ONE LEAK. WHILE CUTTING-OUT THE LEAKING PORTION OF A SERVICE PIPE WITH A BATTERY POWERED SAW, NATURAL GAS IGNITED. IMMEDIATELY, THE FIRE WAS EXTINGUISHED AND THE FLOW OF GAS WAS STOPPED. A CREW MEMBER RECEIVED MINOR BURNS TO HIS FACE. EMPLOYEE SHOULD HAVE VERIFIED THE SERVICE WAS PROPERLY PURGED OUT OF SERVICE PRIOR TO USING THE BATTERY POWERED SAW OR A MANUAL PIPE CUTTER COULD HAVE ALSO BEEN USED TO ELIMINATE THE SOURCE OF IGNITION."