2005 GILLIG 35 AND 40 FOOT LOW FLOOR
1 recalls — 0 complaints — 5 TSBs
05V271000 Jun 9, 2005
SUSPENSION:FRONT
Defect Description
ON CERTAIN TRANSIT BUSES, THE CAST CLAMP PORTION OF THE TORQUE ROD COULD CRACK UNDER INITIAL TORQUEING OF THE CLAMP FASTENERS RESULTING IN BREAKAGE OR CRACKS. CASTING POROSITY AND INCORRECT HEAT TREATMENT CAUSED POTENTIAL WEAKNESS IN THE CAST CLAMP PORTION OF THE TORQUE ROD.
Consequence
THIS COULD RESULT IN LOSS OF VEHICLE CONTROL AND A CRASH COULD OCCUR WITHOUT PRIOR WARNING.
Remedy
DEALERS WILL REPLACE THE CAST IRON TORQUE ROD CLAMPS WITH A FABRICATED STEEL CLAMPS FREE OF CHARGE. THE RECALL BEGAN ON JUNE 17, 2005. OWNERS MAY CONTACT GILLIG AT 510-785-1500.
No complaints found for this vehicle.
Technical Service Bulletins — 2005 GILLIG 35 AND 40 FOOT LOW FLOOR
5 manufacturer communications from 2 unique bulletins. TSBs describe known problems and recommended fixes from the manufacturer.
Most Affected Components
| Component | Bulletins |
|---|---|
| 162000 STRUCTURE:BODY | 1 |
| 010000 STEERING | 1 |
| 013000 STEERING:GEAR BOX (OTHER THAN RACK AND PINION) | 1 |
| 350000 EQUIPMENT | 1 |
| 356000 EQUIPMENT ADAPTIVE/MOBILITY | 1 |
FS-2016-06
Dec 20, 2016
010000 STEERING
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
013000 STEERING:GEAR BOX (OTHER THAN RACK AND PINION)
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
350000 EQUIPMENT
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
356000 EQUIPMENT ADAPTIVE/MOBILITY
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2012-02
Jan 13, 2012
162000 STRUCTURE:BODY
GILLIG: GILLIG'S RECOMMENDATIONS FOR THE UNDERBODY MAINTENANCE CAN BE FOUND IN CHAPTER 11 OF YOUR SERVICE MANUAL. *JS
GILLIG 35 AND 40 FOOT LOW FLOOR — All Years Overview
Complete safety history for the GILLIG 35 AND 40 FOOT LOW FLOOR across all model years (2004–2005).
3
Total Recalls
0
Total Complaints
0
Investigations
0
Reported Crashes
0
Reported Fires
0
Reported Deaths
GILLIG 35 AND 40 FOOT LOW FLOOR — Year by Year
Compare recalls and complaints across model years. Click any year to see full details.
| Year | Recalls | Complaints | |
|---|---|---|---|
| 2005 (current) | 1 | 0 | |
| 2004 | 2 | 0 | View |