1990 FORD F350

7 recalls — 50 complaints

01I008000 Jul 19, 2001
FUEL SYSTEM, GASOLINE
THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. VEHICLE DESCRIPTION: 1990-1993 FORD F-SERIES VEHICLES EQUIPPED WITH DUAL FUEL TANKS AND 4.9, 5.0,5.8, OR 7.5 LITER GASOLINE FUELED ENGINES. SOME VEHICLES CAN EXPERIENCE A CROSS TANK FUEL FLOW CONDITION DUE TO A DAMAGED CHECK VALVE IN THE FUEL PUMP/SENDER ASSEMBLY. FUEL MAY BE SUPPLIED FROM ONE TANK AND SOME OR ALL OF THE UNUSED FUEL MAY BE RETURNED TO THE OTHER TANK.
Remedy: FORD IS EXTENDING THE WARRANTY FOR POTENTIAL FUEL CROSS-FLOW TO 12 YEARS OF SERVICE OR 150,000 MILES FROM THE VEHICLE'S WARRANTY START DATE, WHICHEVER OCCURS FIRST. THIS COVER WILL AUTOMATICALLY TRANSFER TO SUBSEQUENT OWNERS AT NO CHARGE. IF A VEHICLE ALREADY HAS MORE THAN 150,000 MILES, THIS OVERAGE WILL LAST UNTIL DECEMBER 31, 2001. IF THE VEHICLE IS EXPERIENCING A FUEL CROSS-FLOW CONDITION, DEALERS WILL REPAIR THE CONDITION FREE OF CHARGE.
1,556,221 vehicles affected
96V071000 Apr 25, 1996
ELECTRICAL SYSTEM:IGNITION
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
7,900,000 vehicles affected
94V040000 Feb 23, 1994
FUEL SYSTEM, GASOLINE:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS
THE STEEL FUEL RETURN TUBES THAT CONNECT THE FRAME FUEL RETURN LINES WITH THE ENGINE FUEL RAIL CAN CONTACT THE PINCH WELD FLANGE CONNECTING THE DASH PANEL TO THE FLOOR PAN. CONTINUED CONTACT LEADS TO ABRASION OF THE STEEL FUEL RETURN TUBE AND EVENTUALLY RESULTS IN A FUEL LEAK.
Remedy: FORD DEALERS WILL REPLACE THE FUEL RETURN TUBES WITH FLEXIBLE STAINLESS STEEL BRAIDED/TEFLON TUBES. DEALERS WILL ALSO INSPECT THE FUEL SUPPLY TUBES.
89,770 vehicles affected
93V125000 Aug 2, 1993
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
1,131,000 vehicles affected
92V026000 Mar 3, 1992
SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:DRUM:SHOES/LININGS
A REVISED BRAKE LINING NOISE INSULATOR RESULTED IN A DECREASE IN THE THERMAL INSULATION BETWEEN THE BRAKE LINING AND THE FRONT BRAKE CALIPER PISTON. THIS CAUSED GREATER HEAT TRANSFER TO THE CALIPER PISTONS WITH THE POTENTIAL TO OVERHEAT THE BRAKE FLUID AND DIMINISH BRAKE EFFECTIVENESS DURING SEVERE BRAKING CONDITIONS.
Remedy: ADD SNAP-IN INSULATORS THAT ATTACH TO EACH OF THE FRONT BRAKE CALIPER PISTONS. IN ADDITION, VEHICLES WITH 7.5 L ENGINES WILL HAVE INSULATION ADDED TO THE ENGINE COMPARTMENT BRAKE LINES.
467,000 vehicles affected
90V101000 Jun 1, 1990
POWER TRAIN:AUTOMATIC TRANSMISSION:GEAR POSITION INDICATION (PRNDL)
UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.
Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.
111,000 vehicles affected
89V141000 Aug 15, 1989
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.
Remedy: REPLACE FUEL LINE ASSEMBLY.
1,100 vehicles affected
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES Jun 17, 2005
DT: THE CROSS OVER OF THE FUEL IMPROPERLY OVERFILLS THE SECOND TANK, SPILLING FUEL OUT OF VEHICLE. THERE WERE 2 SAFETY RECALLS OF THIS ITEM. BUT FORD WAS SAYING THAT ONE RECALL WAS TAKEN CARE OF BY A PREVIOUS OWNER. THE SECOND RECALL EXPIRED, AND FORD WILL NOT FIX THIS PROBLEM. FORD HAS BEEN CONTACTED BY THE CUSTOMER AND THE REPAIR FACILITY. FORD WAS STILL NOT WILLING TO HELP. THIS HAS BEEN A PROBLEM FOR A COUPLE OF MONTHS. THE CUSTOMER WAS HAVING IT REPAIRED AT HIS OWN EXPENSE. IF THERE WAS A SAFETY ISSUE ON THIS PROBLEM IT SHOULD BE TAKEN CARE OFF BY DEALER NO MATTER HOW MANY TIMES IT COMES UP.*AK *JB
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK Aug 27, 2004
VEHICLE WAS TAKEN TO DEALER FOR RECALL REPAIRS ABOUT 5 YEARS AGO. VEHICLE HAD DUEL GAS TANKS. THE RECALL WAS ISSUED BECAUSE ONE TANK WOULD PUMP GAS INTO THE OTHER TANK, AND WHEN IT WAS FULL IT WOULD SPILL OVER, CREATING A FIRE HAZARD. AFTER RECALL REPAIRS WERE DONE THE PROBLEM RECURRED. CONSUMER FELT THAT THE PROPER WORK FOR THE RECALL WAS INSUFFICIENTLY DONE BECAUSE OF WHAT WAS HAPPENING CURRENTLY. *AK
TIRES:TREAD/BELT Jun 18, 2003
WHILE TRAVELING, THE CONSUMER HEARD A LOUD POPPING NOISE. THE CONSUMER PULLED OVER AND SAW THE RIGHT FRONT TIRE TREAD SEPARATED FROM THE WHEEL. FIRESTONE STEELTEX, LT 265/75R16. *AK *SCC *JB
FUEL SYSTEM, GASOLINE:DELIVERY Feb 11, 2002
I AM SPEAKING ON BEHALF OF THE OWNER, I AM TED SCHORE OF OCALA,FL PINEYWOODS AUTOMOTIVE 352-629-6727 THE CUSTOMER HAD THE TRUCK TOWED IN BECAUSE OF A NO START (BATTERY WAS BAD) AND AFTER THE REPAIR AND RUNNING NOTICED A FUEL SMELL AND LARGE FUEL LEAK FROM THE BELL HOUSING AREA. THE LEAK WAS FROM THE FUEL RETURN LINE FROM THE PRESSURE REGULATOR TO THE CONNECTION TO THE LINE FROM THE TANK, APPROX 12 INCHES LONG AND METAL. THE PINCH WELD ABOVE THE BELL HOUSING RUBBED THE LINE THROUGH. I CHECK FOR SERVICE BULLETINS AND RECALLS AND FOUND A RECALL NUMBER 94S80, I CALLED THE LOCAL FORD DEALER TO ARRANGE TOWING AND FOR THE RECALL TO BE PERFORMED AND WAS TOLD THE RECALL HAD ALREADY BEEN DONE BY BAY HARBOR FORD IN ENGLEWOOD FLORIDA. I CALLED THE 1-800 NUMBER GIVEN TO ME BY THE LOCAL DEALER (DEARBORN?) AND WAS TOLD THE IT HAD INDEED BEEN DONE BUT THEY WERE NOT GOING TO DO ANYTHING ABOUT IT NOW, I INFORMED THEM THAT ALTHOUGH THEY SHOW IT BEING DONE THAT IT WAS NOT THEY PRETTY MUCH SAID IT WAS NOT FORDS PROBLEM AND THE CUSTOMER WOULD HAVE TO PAY TO HAVE IT REPAIRED. WELL MY PROBLEM IS THIS. THE BAY HARBOR FORD HAS BEEN PAID TO PERFORM THE RECALL BUT IT HAS NOT BEEN DONE. THE OLD LINE WAS METAL WHERE THE NEW RECALL WAS FOR A PLASTIC LINE, THE KIT ALSO HAD A VINYL TRIM PIECE TO COVER THE PINCH WELD THAT RUBBED THE LINE IN THE FIRST PLACE. THE KIT NUMBER FROM FORD WAS F4TZ-9J332-A I WAS TOLD IT WAS ON NATIONAL BACK ORDER BUT THE PARTS MAN WAS ABLE TO GET IT THROUGH ANOTHER FORD DEALER. I JUST WANTED TO INFORM YOU OF THIS BECAUSE IT WAS A REAL FIRE DANGER AND UNSAFE TO DRIVE. FORD"S ATTITUDE WAS JUST PLAIN WRONG. I WOULD THINK THAT THE DEARBORN OFFICE WOULD HAVE PAID TO HAVE THE TRUCK TOWED TO THE NEAREST DEALER, INSPECTED, MADE NOTE OF THE RECALL NOT BEING DONE, PERFORMED THE RECALL AND GO AFTER BAY HARBOR FORD, BUT IN SO MANY WORDS I WAS TOLD TOUGH. I THINK I SAVED THEM FROM A BIG LAWSUIT AS THE CUSTOMER HAULS HORSES. BIG DOLLAR HORSES.
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY Feb 5, 2002
THERE HAS BEEN MULTIPLE RECALL NOTICES FOR THE FORD F-SERIES DUAL FUEL TANK DESIGN FLAW. WHEN BOTH TANKS ON MY TRUCK ARE FILLED TO CAPACITY, ONE TANK WILL EMPTY ITS CONTENTS INTO THE OTHER FULL FUEL TANK AND WILL SPRAY OUT FUEL ON TO THE ROAD AND OTHER VEHICLES POSING A GREAT FIRE HAZARD. EACH TIME I HAVE TAKEN MY TRUCK IN TO HAVE THE RECALL PERFORMED ON MY TRUCK BY THE LOCAL DEALER (MCCULLOM FORD IN SPOKANE WA) THEY HAVE RETURNED MY TRUCK WITHOUT FIXING THE PROBLEM. THEY HAVE INDICATED THAT THEY HAVE PERFORMED FORDS RECOMMENDED FIX AND THAT IT HAS NOT SOLVED THE PROBLEM. THIS IS A FORD MOTOR CO. DESIGN FLAW. I WOULD LIKE MORE INFORMATION ON HOW I CAN HAVE THIS UNSAFE CONDITION ADDRESSED. THANK YOU.*AK
ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:MANIFOLD/HEADER/MUFFLER/TAIL PIPE Oct 15, 2001
WHILE DRIVING EMERGENCY SPARE TIRE UNDERNEATH VEHICLE CAUGHT ON FIRE. FIRE WAS CAUSED BY EXHAUST PIPE BEING TOO CLOSE. MANUFACTURER NOTIFIED. FEEL FREE TO PROVIDE ANY FURTHER INFORMATION.*AK
Fire
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES Feb 20, 2001
93 V 125 000/FUEL TANK ASSEMBLY: VEHICLE EXPERIENCED A PORTION OF UNUSED FUEL FROM ONE TANK TO BE RETURNED TO SECOND TANK. WHEN THIS OCCURRED SECOND TANK EXCEEDED, CAUSING FUEL SPILLAGES. SPILLED FUEL COULD RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. DEALER NOTIFIED, AND INFORMED CONSUMER THAT VIN SHOWED THAT RECALL REPAIRS WERE DONE ON THIS VEHICLE. BUT PROBLEM HAS REOCCURRED, AND DEALER REFUSED TO HELP IN THIS MATTER. PLEASE FEEL FREE TO PROVIDE ANY FURTHER DETAILS ON THIS MATTER: *AK
TIRES Nov 27, 2000
THIS PARTICULAR TIRE EXPLODED @ ABOUT 60 MPH ON MY TRUCK .I HAD A 5TH WHEEL TRAILER ON BEHIND AT THE TIME . IT CAUSED 1150.00 DOLLARS DAMAGE TO THE TRUCK. THIS IS THE 7TH OR EIGHTH TIRE OF THE SAME BRAND &TYPE THAT I HAD GO BAD. THE OTHERS HAD THE BELTS COME LOOSE AND START VIBERATING. I WOULD TAKE THEM BACK TO A SEARS STORE AND THEY WOULD GIVE ME AN ADJUSTMENT AND CHARGE ME 75% OF A NEW TIRE AND PUT THE SAME TYPE BACK ON. I WOULD QUESTION THEM ABOUT THE SAFTY OF THE TIRE & THEY WOULD JUST SHAKE THEIR HEADS. THE FIRST TWO TIRES WERE BOUGHT IN FARMINGTON NM. ON THE28TH OF JULY 1998.THE LAST TWO WERE BOUGHT THE 19 OF OCT.1999 . TWO MORE WERE REMOVED THE 6TH OF SEPT. 2000 BUT WERE REPLACED WITH DIFFERENT TYPE . IWAS TOLD THE QUIT MAKING IT IN MY SIZE. I STILL HAVE THREE IN MY POSESSION . ONE IS BLOWN AND THEY WANT ME TO SEND IT TO PIRELLI FOR EVAUATION. SEARS WANTS TO PASS THE BUCK TO PIRELLI . IT IS MY CONTENTION THE TIRES ARE DIFFENETLY DANGEROUS TO THE PUBLIC. I WAS VERY LUCKY TO HAVE BEEN ABLE TO BRING MY TRUCK UNDER CONTROL . I MIGHT ADD THAT THESE TIRES THAT HAVE LOST THEIR BELTS HAVE BEEN ON ALL FOR CORNERS OF THE TRUCK WHEN THEY WENT BAD. THANK YOU FOR YOUR TIME.*AK (DOT NUMBER: CHOR524 TIRESIZE: 235 85 R16)
ENGINE AND ENGINE COOLING:ENGINE:GASOLINE Nov 15, 2000
CONSUMER WAS TRAVELING 60 MPH & VEHICLE STALLED. REAR FUEL TANK SPILLED GAS ALL OVER HIGHWAY. WHEN VEHICLE WAS BEING TOWED TO FORD DEALER FUEL TANK FELL OFF. SHIELD THAT GUARDS THE TANK DROPPED & GAS LINES WERE DISCONNECTED. *AK
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY Nov 15, 2000
CONSUMER WAS TRAVELING 60 MPH & VEHICLE STALLED. REAR FUEL TANK SPILLED GAS ALL OVER HIGHWAY. WHEN VEHICLE WAS BEING TOWED TO FORD DEALER FUEL TANK FELL OFF. SHIELD THAT GUARDS THE TANK DROPPED & GAS LINES WERE DISCONNECTED. *AK
ENGINE AND ENGINE COOLING:ENGINE:GASOLINE Apr 26, 2000
CONSUMER RECEIVED LETTER OF CONCERN (98C01) WHICH DISCUSSES ENGINE PROBLEMS, HOWEVER VEHICLE EXPERIENCED SEVERE ENGINE FAILURE DUE TO LACK OF PRIOR NOTIFICATION, DENIED REIMBURSEMENT COSTS OF REPAIR. *MJS
ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS Apr 13, 2000
BACK OF THE FUSE BOX MELTED, AND CONSUMER LOST ELECTRICAL POWER. *AK
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES Oct 1, 1999
WHEN FILLING UP BOTH DUAL TANKS FUEL SPITS BACK OUT AND THAT COULD CAUSE A FIRE. *AK
ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:EMISSION CONTROL:CATALYTIC CONVERTOR May 5, 1999
ENGINE WAS LOSING RAW FUEL FROM A LEAK WHICH WAS GOING INTO THE EXHAUST SYSTEM. THIS CAUSED THE CATALYTIC CONVERTOR TO BURN. HAVE BEEN TO SERVICE CENTER. *AK
ENGINE AND ENGINE COOLING:ENGINE:GASOLINE May 5, 1999
ENGINE WAS LOSING RAW FUEL FROM A LEAK WHICH WAS GOING INTO THE EXHAUST SYSTEM. THIS CAUSED THE CATALYTIC CONVERTOR TO BURN. HAVE BEEN TO SERVICE CENTER. *AK
ENGINE AND ENGINE COOLING:EXHAUST SYSTEM Mar 8, 1999
NUMBER 8 CYLINDER BECAME POROUS CAUSING THE ANTIFREEZE TO ENTER THE COMBUSTION CHAMBER WHICH CAUSED VAPOR AND HYDRO-LOCK (EMIT WHITE VAPOR FROM EXHAUST).
ENGINE AND ENGINE COOLING:ENGINE:GASOLINE Oct 14, 1998
ENGINE FAILED TWO TIMES DUE TO CONTAMINATION AS PER RECALL NOTICE.
FUEL SYSTEM, GASOLINE:FUEL INJECTION SYSTEM:INJECTORS Oct 14, 1998
FUEL INJECTORS FAILED.
FUEL SYSTEM, GASOLINE:DELIVERY:FUEL PUMP Oct 14, 1998
FUEL PUMP FAILED.
ENGINE AND ENGINE COOLING:ENGINE Oct 14, 1998
OIL PRESSURE SENDING UNIT FAILED.
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES Sep 18, 1998
FUEL TANK SELECTION SWITCH FAILURE.
UNKNOWN OR OTHER Sep 8, 1998
OWNER CANNOT FIND INFORMATION ON RECALL NUMBER 91V146000.
SERVICE BRAKES, HYDRAULIC:ANTILOCK/TRACTION CONTROL/ELECTRONIC LIMITED SLIP Aug 14, 1998
INTERMITTENTLY WHEN THE BRAKES ARE APPLIED THE PEDAL GOES TO THE FLOOR, RESULTING IN EXTENDED STOPPING DISTANCES. THE DEALER HAS REPLACED THE MASTER CYLINDER/ BOOSTER PUMP/BRAKE BOOSTER, FRONT CALIPERS AND BRAKE SHOES .
SERVICE BRAKES, HYDRAULIC:POWER ASSIST:VACUUM Aug 14, 1998
INTERMITTENTLY WHEN THE BRAKES ARE APPLIED THE PEDAL GOES TO THE FLOOR, RESULTING IN EXTENDED STOPPING DISTANCES. THE DEALER HAS REPLACED THE MASTER CYLINDER/ BOOSTER PUMP/BRAKE BOOSTER, FRONT CALIPERS AND BRAKE SHOES .
SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:DISC Aug 14, 1998
INTERMITTENTLY WHEN THE BRAKES ARE APPLIED THE PEDAL GOES TO THE FLOOR, RESULTING IN EXTENDED STOPPING DISTANCES. THE DEALER HAS REPLACED THE MASTER CYLINDER/ BOOSTER PUMP/BRAKE BOOSTER, FRONT CALIPERS AND BRAKE SHOES .
ENGINE AND ENGINE COOLING:EXHAUST SYSTEM Jun 15, 1998
TRUCK WAS IN USE WHEN IT BEGAN TO EMIT A WHITE VAPOR FROM EXHAUST, AFTER HEAD REMOVED FOUND OK, DISCOVERED 8 CYLINDER HAD BECOME POROUS, CAUSING ANTIFREEZE TO ENTER THE COMBUSTION CHAMBER WHICH CAUSED THE VAPOR AND HYDRO-LOCK.
ENGINE AND ENGINE COOLING:ENGINE Mar 11, 1998
ENGINE BLEW A HEAD GASKET.
SERVICE BRAKES, HYDRAULIC:ANTILOCK/TRACTION CONTROL/ELECTRONIC LIMITED SLIP Feb 20, 1998
BRAKES FAILED, REPAIRED, HOWEVER STILL FAIL.
POWER TRAIN:AUTOMATIC TRANSMISSION Feb 20, 1998
TRANSMISSION HAS FAILED FIVE TIMES.
SEAT BELTS Feb 20, 1998
SEAT BELT FAILED.
SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:DISC:ROTOR Dec 9, 1997
THE DEFECTIVE BRAKE ROTOR CRACKED IN HALF 9 TIMES IN 80,000 MILES WHICH CAUSED THE BRAKING SYSTEM TO MALFUNCTION. DEALER CANNOT DETERMINE PROBLEM. ROTORS HAVE CRACKED NINE TIMES. *SLC
SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS Sep 23, 1997
BRAKES OVERHEATED DUE TO ENGINE HEAT ON UNSHIELDED BRAKE LINE CAUSED BRAKES TO OVERHEAT AND BECOME INOPERABLE. *AK
POWER TRAIN:AUTOMATIC TRANSMISSION Mar 25, 1997
AUTOMATIC TRANSMISSION BUSHING FAILED TWICE DUE TO DESIGN.
POWER TRAIN:CLUTCH ASSEMBLY:PEDAL/HAND LEVER(MOTORCYCLE) Mar 10, 1997
FLUID LEAKED FROM CLUTCH SLAVE CYLINDER LINED AND VIBRATED ALONG EXHAUST MANIFOLD WHICH RESULTED IN A FIRE. *AK
Fire
SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS Dec 31, 1996
ECLIP MISSING FROM TRUCK, CAUSING ACCIDENT/INJURIES/FATALITY.
5 injured 1 deaths
POWER TRAIN:AUTOMATIC TRANSMISSION:TORQUE CONVERTER Dec 23, 1996
THE TORQUE CONVERTER HAS BEEN REPLACED THREE TIMES BY THE DEALER AND WHEN OUT AGAIN DEALER WOULDN'T REPLACE IT . *AK
SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS Jul 17, 1996
WHEN APPLYING THE BRAKES, THE BRAKE PEDAL WENT CLEARLY TO THE FLOOR. HAD TO USE THE EMERGENCY BRAKE TO STOP TRUCK. *AK
SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:DISC:PADS Jun 24, 1996
BRAKE SHOES REPLACED. *SD
VISIBILITY:WINDSHIELD WIPER/WASHER:MOTOR Jun 24, 1996
WINDSHIELD WIPER MOTOR REPLACED. *SD
SUSPENSION:FRONT:WHEEL BEARING Jun 24, 1996
WHEEL BEARING REPLACED. *SD
SUSPENSION:FRONT Jun 24, 1996
FRONT END SHAKES. *SD
SERVICE BRAKES, HYDRAULIC:BRAKE FLUID LOW WARNING: LAMP Jun 24, 1996
BRAKE LININGS REPLACED. *SD
POWER TRAIN:CLUTCH ASSEMBLY Jun 24, 1996
CLUTCH REPLACED. *SD
SERVICE BRAKES, HYDRAULIC:POWER ASSIST:HYDRAULIC Jun 24, 1996
POWER BRAKE PUMP REPLACED. *SD
STEERING:LINKAGES:TIE ROD ASSEMBLY Jun 24, 1996
OUTER TIE ROD END REPLACED. 8SD
SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:DISC:CALIPER Jun 24, 1996
BRAKE CALIPERS BROKE. *SD
SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS Jun 24, 1996
FRONT BRAKES REPLACED. *SD
ENGINE AND ENGINE COOLING:ENGINE:DIESEL Jun 24, 1996
DIESEL ENGINE REPLACED. *SD
ELECTRICAL SYSTEM:IGNITION:SWITCH Jun 24, 1996
IGNITION SWITCH REPLACED. *SD
POWER TRAIN:AXLE ASSEMBLY:AXLE SHAFT:SEAL Jun 24, 1996
GREASE SEALS REPLACED. *SD