Browse Device Recalls
78 FDA medical device safety recalls.
FDA Medical Device Recall Enforcement Database
Browse 78 FDA medical device recall enforcement actions. Each entry includes the device description, reason for recall, classification (Class I through III based on severity), recalling firm, and distribution details. Use the filters below to search by year, classification, state, or keyword.
Medical Device Recalls
Browse 78 FDA device recalls.
| Date | Product | Reason | Class | Firm |
|---|---|---|---|---|
| Oct 15, 2024 | Brand Name: Atlan Product Name: Atlan A300 Model/Catalog Number: 8211300 ... | The Atlan anesthesia workstation either indicated a failure of the piston ventilator before use o... | Class I | Draeger Medical, Inc. |
| Oct 15, 2024 | Brand Name: Atlan Product Name: Atlan A350 Model/Catalog Number: 8211500 S... | The Atlan anesthesia workstation either indicated a failure of the piston ventilator before use o... | Class I | Draeger Medical, Inc. |
| Oct 15, 2024 | Brand Name: Atlan Product Name: Atlan A350XL Model/Catalog Number: 8621600 ... | The Atlan anesthesia workstation either indicated a failure of the piston ventilator before use o... | Class I | Draeger Medical, Inc. |
| Oct 15, 2024 | Brand Name: Atlan Product Name: Atlan A300XL Model/Catalog Number: 862140... | The Atlan anesthesia workstation either indicated a failure of the piston ventilator before use o... | Class I | Draeger Medical, Inc. |
| Mar 20, 2024 | Dr¿ger Perseus A500 Anesthesia Workstation | Unexpected shutdown while operating on battery power. | Class I | Draeger Medical, Inc. |
| Jul 12, 2023 | Carina Sub-Acute Care Ventilator | Presence of polyether polyurethane (PE-PUR) and emission of 1,3-Dichloropropan-2-ol that exceed t... | Class I | Draeger Medical, Inc. |
| Jun 12, 2023 | Oxylog 3000 Plus emergency and transport ventilator | Draeger has become aware of instances where the device stopped working when in use when transitio... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | ID Coax 180, MP03375 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | VentStar Coax (P) 150, MP00379 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | VentStar Watertrap (P) 180 w/oLL, MP00362 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | VentStar Bag Set (N) 110, MP00383 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | Ventstar Coax 230, MP03376 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | Anesthesia Circuit Kit Coax HEPA, MP17102 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | VentStar breathing bag Set (P) 110, MP00384 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | VentStar Basic (N) 180, MP00353 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | Anesthesia Circuit Kit Coax 1, MP02730 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | Ventstar Coax 180, MP03374 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | Anesthesia Circuit Kit Coax 3, MP02732 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | VentStar Basic (P)250, MP00352 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | ID Circuit Basic (P) 180, MP01340 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | Ventstar Coax, MP03373 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | VentStar Anesthesia (N) 180, MP00333 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | VentStar Watertrap (P) 180, MP00361 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | VentStar Watertrap (N) 180, MP00363 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | Anesthesia Set Coax 180, MP03384 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | VentStar Anesthesia WT (P)180, MP00374 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | Seattle PAP Plus, MP02260 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | Set2Go Ventilation 12 (A), MP07968 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Apr 17, 2023 | VentStar Basic (P)180, MP00351 | Glued connections of the breathing circuit can become loose before or during ventilation resultin... | Class I | Draeger Medical, Inc. |
| Jan 23, 2023 | NovaStar TS, Anti-Asphyxia Valve, Reusable, Material Numbers MP01576 (Size S)... | The magnets used in the swivel frame/tube set and the headgear clips might impact medical devices... | Class I | Draeger Medical, Inc. |
| Jan 23, 2023 | NovaStar TS, Standard elbow, Reusable, Material Numbers MP01579 (Size S), MP0... | The magnets used in the swivel frame/tube set and the headgear clips might impact medical devices... | Class I | Draeger Medical, Inc. |
| May 16, 2022 | Drager SafeStar 55, Catalog No. MP01790 | Possible occlusion of filters due to manufacturing error. | Class I | Draeger Medical, Inc. |
| Feb 14, 2022 | Babylog VN500 Ventilator with Software 2.51.01 and Lower- intended for the ve... | Cybersecurity Improvement Action-not equipped against potential cyber security threats | Class II | Draeger Medical, Inc. |
| Feb 14, 2022 | Evita V500 Ventilator with Software 2.51.01 and Lower - intended for the vent... | Cybersecurity Improvement Action-not equipped against potential cyber security threats | Class II | Draeger Medical, Inc. |
| Dec 16, 2021 | Draeger Fabius MRI Anesthesia Machine, Catalog Number 8607300 | 26 Fabius MRI Anesthesia machines were distributed with internal hoses routing Oxygen to the Oxyg... | Class II | Draeger Medical, Inc. |
| Sep 10, 2021 | Evita V500 Ventilator with Installed CO2 Measurement Option-Intended for the ... | Software 2.51 and Lower with Installed CO2 Measurement Option, may result in Restart of the Venti... | Class II | Draeger Medical, Inc. |
| Sep 10, 2021 | Babylog VN500 Ventilator with Installed CO2 Measurement Option-intended for t... | Software 2.51 and Lower with Installed CO2 Measurement Option, may result in Restart of the Venti... | Class II | Draeger Medical, Inc. |
| Apr 16, 2021 | Critical Care Ventilator, Catalog Number(s): 8422400: Babylog VN800 - Product... | Three separate and unrelated problems attributed to the software used in the Evita V600, Evita V8... | Class II | Draeger Medical, Inc. |
| Apr 16, 2021 | Critical Care Ventilator, Catalog Number(s): 8422500: Evita V800 - Product Us... | Three separate and unrelated problems attributed to the software used in the Evita V600, Evita V8... | Class II | Draeger Medical, Inc. |
| Apr 16, 2021 | Critical Care Ventilator, Catalog Number(s): 8422300: Evita V600 - Product Us... | Three separate and unrelated problems attributed to the software used in the Evita V600, Evita V8... | Class II | Draeger Medical, Inc. |
| Apr 16, 2021 | Critical Care Ventilator, Catalog Number(s): 8422200: Babylog VN600 - Product... | Three separate and unrelated problems attributed to the software used in the Evita V600, Evita V8... | Class II | Draeger Medical, Inc. |
| Jan 29, 2021 | VentStar Basic (N) 180- Drager Breathing Circuits/Anesthesia Sets Order Numbe... | Y-piece may become detached from the ventilation hose either before or during the ventilation pro... | Class II | Draeger Medical, Inc. |
| Jan 29, 2021 | VentStar Anesthesia (N) 180 - Drager Breathing Circuits/Anesthesia Sets Order... | Y-piece may become detached from the ventilation hose either before or during the ventilation pro... | Class II | Draeger Medical, Inc. |
| Jan 29, 2021 | VentStar Watertrap (N) 180-Drager Breathing Circuits/Anesthesia Sets Order Nu... | Y-piece may become detached from the ventilation hose either before or during the ventilation pro... | Class II | Draeger Medical, Inc. |
| Jan 29, 2021 | ID Circuit Basic (N) 180-Drager Breathing Circuits/Anesthesia Sets Order Numb... | Y-piece may become detached from the ventilation hose either before or during the ventilation pro... | Class II | Draeger Medical, Inc. |
| Dec 21, 2018 | VentStar Anesthesia WT(P) 180, Catalog Number MP00374 Breathing Circuits/... | Incorrectly pre-assembled breathing circuit has potential for incorrect connection/short circuit ... | Class I | Draeger Medical, Inc. |
| Dec 21, 2018 | ID Circuit Basic 250, Catalog Number MP01348 Breathing Circuits/Anesthesi... | Incorrectly pre-assembled breathing circuit has potential for incorrect connection/short circuit ... | Class I | Draeger Medical, Inc. |
| Dec 21, 2018 | VentStar Basic (P) 180, Catalog Number MP00351 Breathing Circuits/Anesthe... | Incorrectly pre-assembled breathing circuit has potential for incorrect connection/short circuit ... | Class I | Draeger Medical, Inc. |
| Dec 21, 2018 | VentStar Basic 180, Catalog Number MP00349 Breathing Circuits/Anesthesia ... | Incorrectly pre-assembled breathing circuit has potential for incorrect connection/short circuit ... | Class I | Draeger Medical, Inc. |
| Dec 21, 2018 | VentStar Basic (P) 250, Catalog Number MP00352 Breathing Circuits/Anesthe... | Incorrectly pre-assembled breathing circuit has potential for incorrect connection/short circuit ... | Class I | Draeger Medical, Inc. |
Frequently Asked Questions
When a device safety issue is identified, the manufacturer or FDA initiates a recall. The FDA publishes an enforcement report detailing the device, the reason for the recall, and distribution. Healthcare facilities and providers are notified to check their inventory and take corrective action.
All types — from simple devices like blood glucose test strips and surgical gloves to complex devices like pacemakers, defibrillators, insulin pumps, hip implants, and ventilators. Software-driven devices are increasingly common in recalls due to bugs and cybersecurity vulnerabilities.
Use the search and filter tools on this page. Each recall entry includes the device description, model numbers, and distribution details so you can determine if your device is affected. Contact your healthcare provider if you find a match.