DE HAVILLAND DHC6

Manston, UK, February 24, 2010

Event Information

DateFebruary 24, 2010
Event TypeINC
LocationManston, UK
CountryUK
Highest Injury-
NTSB NumberENG10RA039
Event ID20100708X20430

Aircraft

MakeDE HAVILLAND
ModelDHC6
Registration #C-FAKB
FAR PartUNK
Aircraft DamageMINR

Conditions

Light Condition-
Weather-

Injuries

Fatal0
Serious0
Minor0
None0
Total Injured0

Full Narrative

On February 24, 2010 during a ferry flight from Calgary, Canada to the Maldives, a De Havilland DHC-6 300 Twin Otter C-FAKB experienced an electrical fire in the power distribution and generator control box located in the roof of the passenger cabin. The crew isolated the electrical systems and successfully diverted to London Gatwick Airport. The source of the fire was traced to the left generator reverse current relay, which was found to have a different part number to the relays authorised for use on the DHC-6 series of aircraft.

The accident is being investigated by United Kingdom AAIB.
United Kingdom
Air Accidents Investigation Branch
Department of Environment, Transport and the Regions
Berkshire Copse Road
Aldershot
Hants
GU11 2HH
United Kingdom
Tel.: (44) 1252 510300
(44) 171 890 5999 (after hours)
Website: http://www.dft.gov.uk

This report is for informational purposes only and contains only information obtained for, or released by, the Government of the United Kingdom.

About This NTSB Record

This aviation event was investigated by the National Transportation Safety Board (NTSB). NTSB investigates all U.S. civil aviation accidents to determine probable cause and issue safety recommendations to prevent future accidents.

All Aviation Events