Roman Roofing Inc

Indirect exposure to electricity greater than 220 volts — Electrocution, electric shock — FORT MYERS BEACH, FLORIDA

HOSPITALIZED — Worker hospitalized after incident at Roman Roofing Inc in FORT MYERS BEACH, FLORIDA
Employer Roman Roofing Inc Report ID 2024043023
Address 112 Lovers Lane City, State ZIP FORT MYERS BEACH, FLORIDA 33931
Event Date April 5, 2024 Outcome Hospitalized
Nature of Injury Electrocution, electric shock Body Part BODY SYSTEMS
Event Type Indirect exposure to electricity greater than 220 volts Source of Injury Power lines, transformers, convertors
Secondary Source Extension ladders
Industry (NAICS) 238160 Inspection # 1740942
GPS Coordinates 26.44000, -81.93000

Incident Narrative

An employee was setting up an extension ladder to access the roof of a house when the ladder contacted a power line, resulting in an electric shock and hospitalization.

Incident Summary

On April 5, 2024, a worker at Roman Roofing Inc in FORT MYERS BEACH, FLORIDA suffered electrocution, electric shock to the body systems. The incident was classified as indirect exposure to electricity greater than 220 volts, with power lines, transformers, convertors identified as the source of injury. The worker was hospitalized.

Context

OSHA has recorded 46 severe injury reports involving "Indirect exposure to electricity greater than 220 volts" incidents in our database. Browse all Indirect exposure to electricity greater than 220 volts injuries.

See all reports for Roman Roofing Inc.

Similar Incidents

Other severe injury reports involving Indirect exposure to electricity greater than 220 volts events:

Date Employer Location Nature Outcome
Jul 11, 2025 Macias Construction and Utilities WILLIS, TEXAS Amputations involving bone loss Hosp., Amp.
Sep 17, 2024 WALSWORTH PUBLISHING COMPANY MARCELINE, MISSOURI Severe wounds, internal injuries and electrocution, electric shock Hosp.
May 6, 2024 Alliant Energy Corporation FOX LAKE, WISCONSIN Electrical burns any degree Hosp.
Mar 13, 2025 Frontera Construction, LLC DEL RIO, TEXAS Electrocution, electric shock Hosp.
Apr 28, 2025 Arkansas Electric Cooperative Corporation KNOXVILLE, ARKANSAS Electrocution, electric shock Hosp.
Jul 26, 2025 ECO Industrial Services PHILLIPSBURG, KANSAS Electrocution, electric shock Hosp.
Oct 7, 2024 Alexis Painting, Inc. AUBURN, ALABAMA Electrocution, electric shock Hosp.
Mar 28, 2025 Winget Pump HEREFORD, TEXAS Electrical burns any degree Hosp.