American Residential Services, LLC

Ignition of vapors, gases, or liquids — Second degree heat (thermal) burns — OMAHA, NEBRASKA

HOSPITALIZED — Worker hospitalized after incident at American Residential Services, LLC in OMAHA, NEBRASKA
Employer American Residential Services, LLC Report ID 20161110825
Address 5615 William St City, State ZIP OMAHA, NEBRASKA 68106
Event Date November 17, 2016 Outcome Hospitalized
Nature of Injury Second degree heat (thermal) burns Body Part Multiple body parts, n.e.c.
Event Type Ignition of vapors, gases, or liquids Source of Injury Cleaning and polishing agents, n.e.c.
Secondary Source Furnaces, heaters
Industry (NAICS) 238220 Inspection # 1193655
GPS Coordinates 41.24000, -96.00000

Incident Narrative

An employee was replacing a furnace in a customer's home and was installing a PVC exhaust pipe. The PVC pipe was to run directly over the water heater out the side of the home. He set his PVC cleaner and glue on top of the water heater (chest height) as he put the exhaust together. While installing the final piece, he cleaned the connection with the PVC cleaner and put the dabber back into the can. When he reached for the glue, he bumped the can of cleaner and it spilled on his chest. He caught the can with his hand but the contents spilled on the floor. The water heater ignited vapors from the cleaner and a fire started, causing first and second degree burns to his chest, right lower arm, right neck, earlobe, left armpit, and both lips.

Incident Summary

On November 17, 2016, a worker at American Residential Services, LLC in OMAHA, NEBRASKA suffered second degree heat (thermal) burns to the multiple body parts, n.e.c.. The incident was classified as ignition of vapors, gases, or liquids, with cleaning and polishing agents, n.e.c. identified as the source of injury. The worker was hospitalized.

Context

OSHA has recorded 503 severe injury reports involving "Ignition of vapors, gases, or liquids" incidents in our database. Browse all Ignition of vapors, gases, or liquids injuries.

See all reports for American Residential Services, LLC.

Similar Incidents

Other severe injury reports involving Ignition of vapors, gases, or liquids events:

Date Employer Location Nature Outcome
Dec 1, 2015 Hi-Tech Trucking and Rigging HOUSTON, TEXAS Third or fourth degree heat (thermal) burns Hosp.
Sep 30, 2016 J.R. Ramon & Sons, Inc. SAN ANTONIO, TEXAS Heat (thermal) burns, unspecified Hosp.
Aug 15, 2017 Pilgrim's - GNP Business Unit ARCADIA, WISCONSIN Heat (thermal) burns, unspecified Hosp.
Feb 28, 2023 Lamb's Yacht Center Operating Company, LLC. JACKSONVILLE, FLORIDA Heat (thermal) burns, unspecified Hosp.
May 12, 2017 ROTH BROTHERS INC. YOUNGSTOWN, OHIO Second degree heat (thermal) burns Hosp.
Oct 13, 2021 Neeltran, Inc. NEW MILFORD, CONNECTICUT Heat (thermal) burns, unspecified Hosp.
Jan 25, 2017 Digco Utility Services ROSENBERG, TEXAS First degree heat (thermal) burns Hosp.
Sep 14, 2023 Sherwood Construction Company, Inc. SAPULPA, OKLAHOMA Heat (thermal) burns, unspecified Hosp.