Vehicle Safety Recalls

Search 30,039 NHTSA recall campaigns covering every vehicle sold in the United States since 1966.

30,039 Recall Campaigns
24,137 Vehicle Models
233 Vehicle Makes
1966–2026 Year Range

What is a vehicle safety recall?

A vehicle safety recall is issued when a manufacturer or the National Highway Traffic Safety Administration (NHTSA) determines that a defect in a motor vehicle creates an unreasonable risk to safety, or that the vehicle fails to meet a federal motor vehicle safety standard. Once a recall is issued, the manufacturer is required by federal law (49 U.S.C. § 30120) to repair, replace, or refund the vehicle without charge to the owner. The repair obligation lasts at least 15 years from the date the vehicle was first sold, regardless of mileage, ownership history, or warranty status.

The list below contains every recall campaign in NHTSA's official database — over 30,039 campaigns covering tens of millions of individual vehicles dating back to 1966. Each entry includes the official NHTSA campaign number (used to schedule the repair at any franchised dealer), the affected component, the defect description, the consequence of the failure, and the manufacturer's remedy. You can filter by make, model year, or keyword. To check whether a specific vehicle has an open recall, use the VIN lookup; to read every recall ever issued for a particular brand, use browse by make.

How to read a recall entry

Each recall card on this page surfaces the four pieces of information that matter most to vehicle owners:

  • Component. The system or part affected by the defect — brakes, airbags, fuel system, electrical, etc. NHTSA uses a standardized component taxonomy.
  • Summary. Plain-English description of the defect and what is expected to fail.
  • Consequence. The actual safety risk — fire, loss of brakes, airbag rupture, sudden stalling. This is the most important field for understanding severity.
  • Remedy. What the dealer will do to fix the vehicle. This tells you how long the repair will take and whether parts are likely to be available.

A small share of recalls — typically less than 3 percent — also carry severity flags such as "Park Outside" or "Do Not Drive." When a recall has one of these flags, NHTSA is recommending that owners take additional precautions until the repair is performed. Park Outside means the defect can ignite a fire even when the vehicle is parked; Do Not Drive means the failure mode is severe enough that NHTSA cannot recommend continuing to operate the vehicle. We have a deeper explainer at Understanding Recall Severity.

Where this data comes from

This page is built on NHTSA's recall flat-file database, which we re-import on the first day of every month. Each individual recall record is sourced directly from NHTSA's public files — we don't paraphrase, summarize, or alter the official descriptions. The summaries you see are the manufacturer's own filings as submitted to NHTSA, lightly reformatted for readability. For the most current status of any specific VIN, the authoritative source is nhtsa.gov/recalls; this page is most useful for browsing patterns across models and years rather than checking the status of one specific car.

Read more from our blog

How to Check If Your Car Has an Open Recall › What to Do If Your Car Is Recalled › Why Recall Repairs Are Always Free › Used Car: 7 Recall Checks to Run First › The Takata Airbag Recall: Full Story › All Articles ›
Clear

Showing 1,809 recalls for FORD

83V017000 Feb 24, 1983
FORD CROWN VICTORIA (1983) — POWER TRAIN:AUTOMATIC TRANSMISSION:LEVER AND LINKAGE:COLUMN SHIFT
THE SHIFT INDICATOR MAY NOT ACCURATELY REFLECT THE SHIFT SELECTOR POSITION. SOME VEHICLES WERE PRODUCED WITH TRANSMISSION CONTROL SELECTOR TUBE RETAINING CLIPS THAT MAY NOT BE HARD ENOUGH. THE CLIP MAY LOOSEN OR FALL OFF, AND THE SELECTOR TUBE MAY BECOME DISPLACED.
36,000 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL REPLACE THE TRANSMISSION CONTROL SELECTOR TUBE RETAINING CLIP AT NO CHARGE TO OWNER.
83V013000 Feb 17, 1983
FORD ESCORT (1981) — SEAT BELTS
THE PORTION OF THE ROOF ABOVE FRAME (RAIL) TO WHICH THE SHOULDER BELT IS ANCHORED MAY HAVE A SLOT THAT CAN COMPROMISE THE STRENGTH OF THE SHOULDER BELT ANCHOR UNDER CERTAIN SEVERE LOADS. (THE SUSPECT AREA IS NOT VISIBLE.) CONSEQUENTLY, SOME VEHICLES INCLUDED IN THIS RECALL MAY NOT MEET THE 3000 POUND ANCHORAGE STRENGTH REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD 210, "SEAT BELT ASSEMBLY ...
245,000 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL INSPECT AND, IF NECESSARY, REINFORCE THE ROOF RAIL INNER PANEL SURROUNDING THE DRAINAGE HOLE AT NO COST TO OWNER.
83V016000 Feb 15, 1983
FORD B600 (1983) — ELECTRICAL SYSTEM:WIRING
ON THE AFFECTED VEHICLES, THE WIRING ASSEMBLY TO THE FLOOR MOUNTED HEADLAMP DIMMER SWITCH MAY BE TOO TIGHT; SHOULD WIRES DISCONNECT, THE HEADLIGHTS WILL NOT OPERATE.
300 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL MODIFY THE DIMMER SWITCH WIRING WITH A WIRE EXTENSION ASSEMBLY AT NO CHARGE TO OWNER.
83V012000 Feb 8, 1983
FORD THUNDERBIRD (1983) — FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
SOME OF THESE VEHICLES MAY HAVE BEEN BUILT WITH FUEL TANKS THAT HAVE INADEQUATELY WELDED FRONT SEAMS THAT CAN LEAK.
2,673 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL DETERMINE IF THE VEHICLE WAS CORRECTED AT THE FACTORY; IF NOT, THE FUEL TANK WILL BE REPLACED AT NO CHARGE TO THE OWNER.
82V135000 Dec 28, 1982
FORD LTD (1981) — SUSPENSION:REAR
THE LOWER CONTROL ARMS MAY HAVE BEEN MANUFACTURED FROM STEEL WITH MATERIAL THICKNESS BELOW THE MINIMUM SPECIFICATIONS FOR POLICE DUTY. THIS COULD LEAD TO CRACKS DEVELOPING IN THE CONTROL ARMS, AND EVENTUALLY, THE POSSIBILITY OF FRACTURE OF AN ARM.
4,361 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL INSTALL NEW REAR SUSPENSION LOWER CONTROL ARMS ON BOTH SIDES OF THE VEHICLE WITHOUT CHARGE.
82V124000 Dec 13, 1982
FORD CLUB WAGON (1983) — FUEL SYSTEM, GASOLINE:DELIVERY:FUEL PUMP
SOME OF THE INVOLVED VEHICLES MAY HAVE A DIODE IN THE ELECTRICAL FUEL PUMP CIRCUIT THAT MAY SHORT DURING ENGINE STARTING DUE TO INADEQUATE CAPACITY TO WITHSTAND CURRENT DRAW. A SHORT CIRCUIT WOULD RESULT IN NORMAL ENGINE STARTING, BUT THE PUMP WILL NOT CONTINUE TO SUPPLY THE ENGINE WITH FUEL.
650 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL REPLACE DEFECTIVE ELEMENT IN THE ELECTRICAL FUEL PUMP CIRCUIT WITH A NEW RELAY FEED WIRING ASSEMBLY WHICH CONTAINS A LARGER CAPACITY DIODE, FREE OF CHARGE.
82V127000 Dec 13, 1982
FORD F350 (1983) — STRUCTURE:FRAME AND MEMBERS:UNDERBODY SHIELDS
FUEL SYSTEM ON THE SUSPECT VEHICLES MAY NOT COMPLY WITH FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY". THESE VEHICLES WERE MANUFACTURED WITHOUT PROJECTILE FUEL TANK SHIELDS.
67 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL INSPECT AND INSTALL A PROTECTIVE FUEL TANK SHIELD WITHOUT CHARGE TO OWNER.
82V120000 Dec 7, 1982
FORD F600 (1980) — SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:HOSES, LINES/PIPING, AND FITTINGS
THE BRAKE MASTER CYLINDER TO CHASSIS TUBE AND HOSE ASSEMBLY MAY HAVE BEEN LOCATED IN SUCH A WAY THAT IT IS SUSCEPTIBLE TO CHAFING DURING VEHICLE OPERATION. CONTINUED CHAFING MAY RESULT IN TUBE OR HOSE FAILURE AND SUBSEQUENT LOSS OF BRAKE FLUID.
33,863 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL INSPECT AND, IF NECESSARY, INSTALL A BRAKE LINE ATTACHING CLIP AND REPLACE ANY DAMAGED BRAKE TUBE AND HOSE ASSEMBLY WITHOUT CHARGE.
82V119000 Dec 7, 1982
FORD B600 (1981) — VEHICLE SPEED CONTROL:CABLES
THESE VEHICLES MAY HAVE BEEN MANUFACTURED WITH AN INCORRECT END CLAMP ON THE HAND THROTTLE ACTUATING CABLE. UNDER CERTAIN CONDITIONS, PERTAINING TO THE CLAMP-TO-THROTTLE CABLE ORIENTATION AND DISTANCES OF THE CABLE TO GOVERNOR SHAFT, THE THROTTLE CABLE END CLAMP MAY INTERFERE WITH THE OUTBOARD ACCELERATOR.
4,617 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL INSPECT HAND THROTTLE CLAMP FOR INTERFERENCE AND, IF NECESSARY, REPLACE THESE CLAMPS FREE OF CHARGE.
82V105000 Oct 26, 1982
FORD F250 (1983) — STRUCTURE:BODY:HOOD:HINGE AND ATTACHMENTS
THE SPRINGS THAT ASSIST IN RAISING THE HOOD MAY DETACH FROM THE HOOD WITHOUT WARNING. THE HOOD CAN BE IN ANY POSITION WHEN THIS OCCURS.
600 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL REPLACE THE HOOD LIFT ASSIST SPRING ASSEMBLIES WITH REVISED PARTS.
82V104000 Oct 26, 1982
FORD E250 (1982) — POWER TRAIN:AXLE ASSEMBLY
ON CERTAIN VEHICLES, THE LOCK WEDGES USED TO SECURE THE AXLE BEARING NUTS TO THE AXLE HOUSING MAY FALL OUT OF POSITION, ALLOWING THE NUT TO LOOSEN. THE NUT ON THE LEFT SIDE MAY FALL OFF, ALLOWING MOVEMENT OF THE AXLE SHAFT.
74,985 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL REPLACE DEFECTIVE LOCK WEDGES WITH AN IMPROVED VERSION. WHEEL BEARINGS WILL BE INSPECTED AND ADJUSTED OR REPLACED, IF NECESSARY.
82V100000 Oct 13, 1982
FORD FAIRMONT (1982) — POWER TRAIN:AUTOMATIC TRANSMISSION
THE PARK LEVER ON THE INVOLVED VEHICLES CONTAINS A DEFECTIVE SPRING WHICH COULD PREVENT AUTOMATIC ENGAGEMENT OF THE PARKING GEAR.
2,089 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE PARK ACTUATING LEVER ROD SPRING WILL BE REPLACED WITH AN UPGRADED SPRING WITHOUT CHARGE TO OWNER.
82V099000 Oct 13, 1982
FORD LTD (1982) — POWER TRAIN:AUTOMATIC TRANSMISSION:LEVER AND LINKAGE:COLUMN SHIFT
AN INCORRECT INSULATOR MAY HAVE BEEN INSTALLED IN THE STEERING SHIFT CANE LEVER ON THE INVOLVED VEHICLES. THIS INSULATOR IS USED TO CONNECT THE TRANSMISSION SHIFT LINKAGE TO THE SHIFT CANE LEVER. IF THE SHIFT LINKAGE WERE TO SEPARATE FROM THE SHIFT LEVER, OPERATOR WOULD BE UNABLE TO SHIFT GEARS. THE TRANSMISSION WILL BE STUCK IN THE LAST GEAR USED BEFORE THE SEPARATION TOOK PLACE.
4,967 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSTALL THE CORRECT INSULATOR WIHTOUT CHARGE TO OWNER..
82V098000 Oct 12, 1982
FORD F250 (1982) — VISIBILITY:REARVIEW MIRRORS/DEVICES:EXTERIOR
ON THE INVOVLED VEHICLES THE DRIVER"S SIDE AND PASSENGER"S OUTSIDE REAR VIEW MIRRORS MAY HAVE BEEN OMITTED. THIS FAILS TO COMPLY WITH FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 111, "REARVIEW MIRRORS".
53 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSTALL THE PROPER MIRRORS WITHOUT CHARGE TO OWNER. IF OUTSIDE MIRRORS HAVE ALREADY BEEN INSTALLED, OWNER HAS THE OPTION TO KEEP THEM AS IS OR HAVE THEM REMOVED AND NEW MIRRORS INSTALLED.
82V087000 Sep 16, 1982
FORD B600 (1982) — VEHICLE SPEED CONTROL:LINKAGES
UNDER CERTAIN TOLERANCE CONDITIONS, THE ACCELERATOR ROD MAY COME INTO CONTACT WITH THE ACCELERATOR RETURN SPRING BRACKET, CREATING THE POSSIBILITY OF A MOMENTARY DELAY IN THE RETURN OF THE ACCELERATOR LINKAGE TO THE IDLE POSITION. THIS CONDITION IS MORE LIKELY TO OCCUR AT 3/4 THROTTLE BECAUSE CLEARANCE BETWEEN THE ACCELERATOR ROD AND BRACKET IS AT A MINIMUM AT THIS POINT.
149 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSTALL A NEW ACCELERATOR RETURN SPRING BRACKET WITHOUT CHARGE TO OWNER.
82V088000 Sep 16, 1982
FORD ESCORT (1983) — FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP
DURING A CRASH BARRIER TEST, THE RUBBER HOSE CONNECTING THE FUEL TANK AND THE METAL FILLER PIPE VENT TUBE WAS CUT, RESULTING IN FUEL LEAKAGE. THE INVOLVED VEHICLES FAIL TO COMPLY WITH FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY".
2,800 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSTALL A BRACE BETWEEN THE RIGHT SIDE REAR QUARTER PANEL AND THE BODY SIDE RAIL TO IMPROVE FUEL TANK IMPACT RESISTANCE.
82V045000 May 11, 1982
FORD ESCORT (1982) — EQUIPMENT:APPLIANCE:AIR CONDITIONER
ON THE INVOLVED VEHICLES, A THERMAL LIMITER IN THE BLOWER MOTOR RESISTOR CIRCUIT OF THE AIR CONDITIONER/HEATER ASSEMBLY MAY NOT FUNCTION AS INTENDED. IF THE BLOWER MOTOR BECOMES JAMMED WHEN THE SYSTEM IS OPERATING IN THE MEDIUM-LOW BLOWER SPEED, THE RESISTOR COILS CAN OVERHEAT CAUSING MELTING AND POSSIBLE IGNITION.
113,000 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL REPLACE THE RESISTOR ASSEMBLY WITH AN IMPROVED VERSION WITHOUT CHARGE TO OWNER.
82V033000 Apr 12, 1982
FORD RANGER (1983) — ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:MANIFOLD/HEADER/MUFFLER/TAIL PIPE
ON THE INVOLVED VEHICLES, THE MUFFLER GRASS SHIELDS WERE INADVERTENTLY OMITTED DURING MANUFACTURE. WITHOUT THE GRASS SHIELD, AND DURING CERTAIN OPERATING CONDITIONS, THE MUFFLER SURFACE TEMPERATURES COULD BECOME HOT ENOUGH TO EXCEED SPECIFIED STANDARDS AND CREATE THE POTENTIAL FOR IGNITING TALL GRASSES IF THEY WERE PRESENT BENEATH A STANDING VEHICLE.
24 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSTALL GRASS SHIELDS ON ALL AFFECTED VEHICLES AT NO COST TO OWNER.
82V031000 Apr 6, 1982
FORD GRANADA (1982) — FUEL SYSTEM, OTHER:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS
SOME OF THE SUSPECT VEHICLES MAY HAVE BEEN PRODUCED WITH IMPROPERLY TIGHTENED PROPANE FUEL SYSTEM FITTINGS IN THE ENGINE COMPARTMENT; FUEL LEAKAGE COULD OCCUR.
116 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSPECT, REPLACE, AND SEAL CERTAIN FUEL SYSTEM CONNECTIONS AT NO COST TO OWNER.
82V027000 Mar 26, 1982
FORD C SERIES (MEDIUM) (1974) — VEHICLE SPEED CONTROL
THE INVOLVED VEHICLES DO NOT CONFORM TO FEDERAL MOTOR VEHICLE STANDARD NO. 124, "ACCELERATOR CONTROL SYSTEMS", DUE TO FAILURE OF THE THROTTLE TO RETURN COMPLETELY TO IDLE UNDER CERTAIN CONDITIONS WITH ONE OF THE TWO ACCELERATOR CONTROL RETURN SPRINGS INOPERATIVE.
3,270 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSPECT AND MODIFY THE THROTTLE TO MEET THE REQUIREMENTS OF THE STANDARD.
82V024000 Mar 15, 1982
FORD F100 (1980) — EQUIPMENT:MECHANICAL:CARRIER/RACK
THE REINFORCEMENT FOR THE IN-BOX SPARE TIRE CARRIER MAY HAVE BEEN ATTACHED USING INCORRECT HEX HEAD BOLTS. IF THE CARRIER AND REINFORCEMENT ATTACHING BOLTS ARE INCORRECT, THE POTENTIAL EXISTS FOR THE TIRE SIDEWALL TO BE DAMAGED OR WEAKENED BY EXTENDED CONTACT WITH THE SHARP EDGES OF THE BOLT HEADS.
12,500 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL REPLACE BOLTS AND ANY DAMAGED SPARE TIRES AT NO COST TO OWNER.
82V023000 Mar 15, 1982
FORD LN7000 (1982) — ELECTRICAL SYSTEM:STARTER ASSEMBLY
SOME OF THE SUSPECT VEHICLES MAY HAVE BEEN PRODUCED WITH THE POSITIVE BATTERY CABLE INCORRECTLY INDEXED AT THE ATTACHMENT TO THE STARTER SOLENOID. CABLE INSULATION DAMAGE COULD OCCUR DUE TO METAL ON METAL CONTACT DURING MAXIMUM ENGINE ROLL CONDITIONS. AN ELECTRICAL SHORT MAY DEVELOP BETWEEN THE BATTERY CABLE AND A BRAKE TUBE. A HOLE COULD BE FORMED IN THE BRAKE TUBE, RESULTING IN LOSS OF BRAKE FLU...
99 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSPECT AND, IF NECESSARY, RE-INDEX THE STARTER POSITIVE BATTERY CABLE ATTACHMENT AT NO COST TO OWNER.
82V004000 Jan 13, 1982
FORD CLUB WAGON (1982) — POWER TRAIN:AUTOMATIC TRANSMISSION:LEVER AND LINKAGE:COLUMN SHIFT
ON SOME OF THE INVOLVED VEHICLES, THE SHIFT ROD IN THE TRANSMISSION MAY NOT BE PROPERLY SEATED IN THE RETENTION GROMMET OF THE STEERING COLUMN SHIFT LEVER ASSEMBLY. IF THE SHIFT ROD WERE TO DISENGAGE, THE DRIVER COULD NOT SELECT THE PROPER TRANSMISSION FUNCTION WHICH WOULD CREATE THE POTENTIAL FOR UNEXPECTED MOVEMENT OF THE VEHICLE.
378 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSPECT THE SHIFT ROD ATTACHMENT AND MAKE SURE IT IS PROPERLY SEATED AT NO COST TO OWNER.
81V151000 Dec 23, 1981
FORD GRANADA (1982) — EQUIPMENT:OTHER:LABELS
INCORRECT INFORMATION ON TIRE PLACARDS CONSTITUTES A FAILURE TO COMPLY WITH FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 110, "TIRE SELECTION AND RIMS". THE INFORMATION CONCERNING TIRE SIZES AND INFLATION PRESSURES IS APPLICABLE TO BOTH TWO AND FOUR DOOR SEDANS. THE STATEMENT COVERS FOUR DOOR BUT FAILS TO SPECIFY TWO DOOR SEDANS.
3,010 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: REVISED PLACARDS WILL BE INSTALLED BY OWNERS, OR BY DEALERS WITHOUT CHARGE.
81V002000 Dec 2, 1981
FORD MUSTANG (1972) — ENGINE AND ENGINE COOLING:COOLING SYSTEM:FAN
DUE TO A MANUFACTURING ERROR, CERTAIN FLEXIBLE-BLADE ENGINE COOLING FANS MAY BE SUBJECT TO FATIGUE CRACKING AND BLADE SEPARATION DURING VEHICLE OPERATION.
123,453 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEFECTIVE FAN WILL BE REPLACED WITH ONE OF AN IMPROVED DESIGN WITHOUT CHARGE.
81V003000 Dec 2, 1981
FORD MUSTANG (1976) — ENGINE AND ENGINE COOLING:COOLING SYSTEM:FAN
THE SEVEN-BLADE ENGINE COOLING FAN IS SUBJECT TO FATIGUE CRACKING DURING NORMAL OPERATION. PORTIONS OF THE BLADES MAY SEPARATE WITHOUT PRIOR WARNING.
81,807 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEFECTIVE FANS WILL BE REPLACED WITH FANS OF AN IMPROVED DESIGN WITHOUT CHARGE.
81V124000 Oct 15, 1981
FORD B600 (1980) — SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:HOSES, LINES/PIPING, AND FITTINGS
THE MASTER CYLINDER TO CHASIS BRAKE TUBE AND HOSE ASSEMBLIES MAY HAVE BEEN MOVED FROM THEIR INTENDED POSITION, WHICH COULD ALLOW CHAFING AGAINST UNDERBODY COMPONENTS. CHAFING PROMOTES WEAR OF THE BRAKE TUBE AND HOSE ASSEMBLY AND COULD CAUSE A LOSS OF BRAKE FLUID.
7,100 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: UPON INSPECTION BRAKE TUBE CLIPS WILL BE INSTALLED, IF NECESSARY, AND BRAKE TUBES AND HOSE ASSEMBLIES WILL BE REPLACED OR REROUTED.
81V121000 Oct 6, 1981
FORD F250 (1981) — WHEELS:MULTI PIECE
THE OWNER"S GUIDE MAY CONTAIN AN ERROR IN THE WHEEL LUG NUT TORQUE SPECIFICATION CHART. INCORRECT INFORMATION COULD RESULT IN IMPROPER TORQUE OF THE LUG NUTS DURING WHEEL REPLACEMENT. LUG NUTS COULD COME LOOSE DURING VEHICLE OPERATION.
16,500 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: AN ADHESIVE-BACKED, REVISED PAGE WILL BE SUPPLIED TO OWNERS FOR INSERTION IN THE OWNER"S GUIDE. IN ADDITION, DEALERS WILL PROVIDE TORQUE VERIFICATION, IF ONE OR MORE WHEELS HAVE BEEN SERVICED, AT NO COST TO OWNERS.
81V105000 Sep 9, 1981
FORD ECONOLINE (1982) — FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
THE INVOLVED VEHICLES MAY NOT MEET THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY". IN A MOVING BARRIER IMPACT TEST FROM THE REAR AT 30 MPH, THE FASTENER ATTACHING THE FUEL SENDER GROUND WIRE TO THE FRAME CROSSMEMBER, AFT OF THE FUEL TANK, PIERCED THE FUEL TANK.
115 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE FUEL SENDER GROUND WIRE ATTACHMENT ON ALL AFFECTED VEHICLES WILL BE RELOCATED TO ELIMINATE THE DANGER, WITHOUT CHARGE TO OWNER.
81V102000 Sep 8, 1981
FORD MUSTANG (1981) — SEATS:FRONT ASSEMBLY:RECLINER
THE HOUSING PLATES ON THE DRIVER SEAT BACK LATCH RECLINER ASSEMBLIES WERE MANUFACTURED WITH SUBSTANDARD MATERIAL PRODUCTS. THIS TAINTED STEEL WAS USED TO PRODUCE SEATBACK LATCHES FOR BOTH THE RIGHT AND LEFT SIDE SEAT ASSEMBLIES. UNDER CERTAIN CONDITIONS, THE DEFECTIVE HOUSING PLATES MAY DISTORT, ALLOWING THE LOCKING TEETH TO DISENGAGE AND TEAR OFF. THIS PERMITS THE SEATBACK TO PIVOT BACKWARDS.
6,500 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: UPON INSPECTION, BOTH DRIVER AND PASSENGER SEAT LATCH/RECLINER ASSEMBLIES, ON VEHICLES EXHIBITING THE SUSPECT DATE CODES, WILL BE REPLACED.
81V092000 Jul 22, 1981
FORD ESCORT (1981) — FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP
SOME OF THE INVOLVED VEHICLES HAVE AN ELECTRICALLY UNGROUNDED FUEL INLET. THESE VEHICLES ARE SUBJECT TO STATIC CHARGE ACCUMULATION AT THE FUEL FILLER PIPE OPENING, WHICH CAN OCCUR IF THESE VEHICLES ARE REFUELED FROM AN ELECTRICALLY UNGROUNDED DISPENSING NOZZLE.
112,000 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: A GROUNDING CONNECTION FROM THE FILLER PIPE INLET TO THE VEHICLE BODY AND A STATIC ELECTRICITY SUPPRESSION ROD INSIDE THE FILLER PIPE WILL BE INSTALLED AT NO CHARGE TO OWNER.
81V090000 Jul 17, 1981
FORD B600 (1981) — SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:HOSES, LINES/PIPING, AND FITTINGS
THE INVOLVED VEHICLES WERE ASSEMBLED WITH THE LEFT FRONT BRAKE TUBE RETAINING CLIP MISSING. THE ABSENCE OF A RETAINING CLIP MAY ALLOW THE BRAKE TUBE TO RUB AGAINST THE SHOCK ABSORBER, CAUSING WEAR ON THE TUBE AND, EVENTUALLY, LOSS OF BRAKE FLUID.
3,700 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: MISSING BRAKE TUBE CLIPS WILL BE INSTALLED AND ANY CHAFED BRAKE TUBES WILL BE REPLACED.
81V084000 Jul 7, 1981
FORD ESCORT (1981) — SERVICE BRAKES, HYDRAULIC:POWER ASSIST:VACUUM
SOME VEHICLES EQUIPPED WITH POWER BRAKE BOOSTERS HAVE FRONT AND REAR SHELLS THAT MAY HAVE BEEN IMPROPERLY JOINED. IMPROPERLY JOINED BOOSTER SHELLS MAY SEPARATE EITHER PARTIALLY OR COMPLETELY DURING BRAKE APPLICATION.
4,338 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: ALL DEFECTIVE BOOSTERS WILL BE REPLACED AT NO CHARGE TO OWNER.
81V072000 Jun 15, 1981
FORD B600 (1980) — ELECTRICAL SYSTEM:WIRING
THE PRIMARY CIRCUIT CONNECTION, WHICH PROVIDES PRIMARY ELECTRICAL POWER TO THE ENGINE, COULD DETERIORATE DUE TO HIGH CURRENT DRAW PRODUCED BY BUILDER-INSTALLED EQUIPMENT.
11,700 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE MAIN CAB WIRING HARNESS ELECTRICAL CONNECTOR WILL BE MODIFIED TO ELIMINATE DETERIORATION AT NO CHARGE TO OWNER.
81V061000 May 21, 1981
FORD F100 (1981) — STRUCTURE
THE INVOLVED TRUCKS WERE MANUFACTURED WITH A CERTAIN PORTION OF SPECIFIED FLOOR PAN INSULATION MATERIAL (BENEATH THE RIGHT FRONT PASSENGER SEAT) OMITTED. BECAUSE OF THIS OMISSION, A SECTION OF THE SHEET METAL FLOOR PAN WAS LEFT EXPOSED OVER THE EXHAUST SYSTEM IN AN AREA OF POSSIBLE PASSENGER CONTACT.
130 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE DEALER WILL INSTALL A REVISED DESIGN FLOORPAN INSULATOR PAD AT NO CHARGE TO OWNER.
81V047000 Apr 7, 1981
FORD EXP (1982) — FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP
CERTAIN VEHICLES MAY NOT MEET APPLICABLE MINIMUM FUEL SPILLAGE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY". DURING A 30 MPH REAR IMPACT TEST, FUEL SPILLAGE LIMITS WERE EXCEEDED BY VEHICLE.
5,200 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: REVISED FUEL FILLER AND VENT PIPE ASSEMBLIES WILL BE INSTALLED ON AFFECTED VEHICLES, WITHOUT CHARGE.
81V045000 Apr 6, 1981
FORD ESCORT (1981) — VEHICLE SPEED CONTROL
FUEL MAY POSSIBLY TRAVEL THROUGH THE SPEED CONTROL VACUUM LINES AND INTO THE SPEED CONTROL ACTUATION DEVICE (SERV0). THE FUEL CAN DAMAGE SEALS IN THE ACTUATOR SERVO AND ALLOW VACUUM LEAKS. SUCH A LEAK COULD ACTIVATE THE SPEED CONTROL WITHOUT ANY ACTION ON THE PART OF THE DRIVER. THIS WOULD CAUSE THE VEHICLE TO GRADUALLY ACCELERATE.
21,000 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: THE VACUUM CHECK VALVE AND HOSE ASSEMBLY WILL BE REPLACED AND THE SPEED CONTROL SERVO WILL BE REPLACED IF IT HAS BEEN DAMAGED.
81V042000 Apr 1, 1981
FORD ECONOLINE (1981) — POWER TRAIN:MANUAL TRANSMISSION:SHIFT PATTERN INDICATOR
THE GEAR POSITION INDICATORS ON CERTAIN VEHICLES MAY BE TOO SHORT TO BE READILY VISIBLE TO SOME DRIVERS. THIS IS NOT IN COMPLIANCE WITH FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 101, "CONTROLS AND DISPLAY", WHICH STATES THAT THE GEAR POSITION DISPLAY MUST BE VISIBLE TO DRIVER.
1,650 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: IF POINTER OF GEAR POSITION INDICATOR IS FOUND TO BE TOO SHORT, IT WILL BE REPLACED WITHOUT CHARGE TO OWNER.
81V035000 Mar 20, 1981
FORD EZ250 (1981) — WHEELS:RIM
CERTAIN VEHICLES MAY NOT HAVE HAD THE DISC PORTION OF THE WHEEL WELDED TO THE RIM DURING MANUFACTURE. CONSEQUENTLY, THE WHEEL COULD BE SUBJECT TO SUDDEN SEPARATION OF THE RIM AND TIRE FROM THE WHEEL DISC.
450 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: SUSPECT WHEELS WILL BE INSPECTED AND REPLACED, IF NECESSARY, AT NO CHARGE.
81V026000 Feb 26, 1981
FORD E350 (1981) — STEERING: STEERING WHEEL/HANDLE BAR
THERE ARE THREE PINCH BOLTS THAT CONNECT TWO UNIVERSAL JOINTS IN THE STEERING COLUMN AND GEARBOX. PINCH BOLTS MAY NOT BE PROPERLY TIGHTENED. STEERING MAY BIND OR LOCK UP.
254 vehicles affected Manufacturer: IVECO TRUCK OF N.A., INC.
Remedy: THE STEERING COLUMN SHAFT COVER WILL BE REMOVED BY DISENGAGING AND REMOVING THE SELF TAPPING SCREWS IN ORDER TO SECURELY FASTEN THE PINCH BOLTS.
81V023000 Feb 13, 1981
FORD F250 (1981) — FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:MOUNTING
CERTAIN VEHICLES MAY HAVE BEEN ASSEMBLED WITHOUT THE SPECIFIED FUEL TANK SHIELD WHICH PREVENTS DIRECT CONTACT BETWEEN THE FUEL TANK AND DRIVELINE COMPONENTS. DURING A 30 MPH FRONTAL BARRIER IMPACT TEST, AS SPECIFIED IN FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY", FUEL LEAKAGE MAY OCCUR.
26 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: VEHICLES WILL HAVE THE EXISTING SEPARATE SKID PLATE OR FUEL TANK SHIELD REMOVED (WHICHEVER WAS INSTALLED ON VEHICLE). A SPECIAL COMBINATION SKID PLATE/FUEL TANK SHIELD ASSEMBLY WILL BE INSTALLED IN ITS PLACE FREE OF CHARGE.
81V008000 Jan 12, 1981
FORD FORD (1970) — POWER TRAIN:AUTOMATIC TRANSMISSION:GEAR POSITION INDICATION (PRNDL)
THIS IS A MANUFACTURER"S NOTICE TO ADVISE OWNERS OF PROPER VEHICLE OPERATION. THE PARKING GEAR MAY NOT BE SECURELY ENGAGED AFTER THE OPERATOR HAS ATTEMPTED TO SHIFT TO PARK. THE VEHICLE MAY APPEAR TO BE IN PARK THOUGH ACTUALLY IN REVERSE. THIS COULD ALLOW THE VEHICLE TO MOVE UNEXPECTEDLY.
21,000,000 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: OWNERS WILL BE PROVIDED WITH A SELF-STICKING LABEL CONTAINING IMPORTANT SAFETY PRECAUTIONS AS A DAILY REMINDER OF THE SERIOUS HAZARDS OF UNEXPECTED VEHICLE MOTION. IT SHOULD BE PLACED INSIDE THE VEHICLE IN AN EASILY SEEN LOCATION.
80V167000 Dec 23, 1980
FORD P600 (1978) — SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:HOSES, LINES/PIPING, AND FITTINGS
SOME OF THE SUBJECT VEHICLES MAY HAVE BEEN BUILT WITH FRONT WHEEL BRAKE HOSES THAT ARE TOO LONG. THIS MAY MAKE IT POSSIBLE FOR THE BRAKE HOSE TO CONTACT A FRONT TIRE DURING A FULL LEFT OR RIGHT TURN, WHICH COULD RESULT IN CHAFING OF THE BRAKE HOSE AND SUBSEQUENT BRAKE FLUID LEAKAGE.
79 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: VEHICLES WILL BE INSPECTED AND, IF NECESSARY, FRONT BRAKE HOSES AND BRACKETS WILL BE REPLACED AT NO CHARGE.
80V152000 Nov 19, 1980
FORD FAIRMONT (1981) — SERVICE BRAKES, HYDRAULIC:PEDALS AND LINKAGES
ON SOME OF THE INVOLVED VEHICLES, THE BRAKE PUSHROD TO BRAKE PEDAL RETAINING PINS MAY BE MISSING OR LOOSE. INSECURELY INSTALLED OR MISSING RETAINERS COULD RESULT IN DISENGAGEMENT OF THE BRAKE PUSHROD AND TOTAL LOSS OF SERVICE BRAKING.
1,500 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSPECT AND, IF NECESSARY, INSTALL A BRAKE PEDAL RETAINING PIN.
80V147000 Nov 13, 1980
FORD LTD (1981) — ELECTRICAL SYSTEM:WIRING:INTERIOR/UNDER DASH
SOME OF THE INVOLVED VEHICLES HAVE ELECTRICAL RELAY SYSTEMS WHICH MAY BE SUSCEPTIBLE TO WATER LEAKAGE INTO THE RELAY CASE. WATER ENTRY MAY CAUSE A SHORT CIRCUIT WITHIN THE RELAY.
18,154 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSPECT VEHICLES FOR THE TYPE OF RELAY USED, REORIENT WIRING HARNESSES AS NECESSARY, AND REPLACE SUSPECT RELAYS WITH NEW PARTS.
80V145000 Nov 10, 1980
FORD F100 (1981) — FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:MOUNTING
DURING A CHANGE IN ASSEMBLY PROCEDURES, CERTAIN OF THE MID-SHIP FUEL TANK STRAPS MAY HAVE BEEN IMPROPERLY INSTALLED OR MISLOCATED. AS A RESULT, THEY FAIL TO CONFORM TO FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY". IN THE EVENT OF A COLLISION, EXCESSIVE FUEL SPILLAGE MAY OCCUR.
6,260 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSPECT AND, IF NECESSARY, RELOCATE FUEL TANK STRAPS WITHOUT CHARGE TO OWNER.
80V144000 Nov 7, 1980
FORD LTD II (1977) — ENGINE AND ENGINE COOLING:COOLING SYSTEM:FAN
SOME OF THE FLEXIBLE FIVE-BLADE ENGINE COOLING FANS MAY BE SUBJECT TO HIGH BLADE STRESSES THAT CAN RESULT FROM RESONANT VIBRATION INPUTS OCCURRING DURING NORMAL VEHICLE OPERATION. THIS CAN LEAD TO FATIGUE CRACKING OF THE BLADES. PORTIONS OF THE BLADE MAY SEPARATE FROM THE FAN ASSEMBLY WITHOUT PRIOR WARNING.
209,100 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL REPLACE FAN WITH AN IMPROVED FIVE-BLADED VERSION WITHOUT CHARGE TO OWNER.
80V143000 Nov 7, 1980
FORD CUSTOM (1973) — ENGINE AND ENGINE COOLING:COOLING SYSTEM:FAN
SOME OF THE FLEXIBLE FIVE-BLADE ENGINE COOLING FANS MAY BE SUBJECT TO HIGH BLADE STRESSES THAT CAN RESULT FROM RESONANT VIBRATION INPUTS OCCURRING DURING NORMAL VEHICLE OPERATION. THIS CAN RESULT IN THE BLADES CRACKING DUE TO FATIGUE, AND PORTIONS OF THE BLADE MAY SEPARATE FROM THE FAN ASSEMBLY WITHOUT PRIOR WARNING.
314,400 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL REPLACE DEFECTIVE FAN WITH ONE OF AN IMPROVED FIVE-BLADED DESIGN, WITHOUT CHARGE TO OWNER.
80V142000 Nov 4, 1980
FORD ESCORT (1981) — FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
ON CERTAIN VEHICLES, METAL FASTENERS THAT WERE USED TO SECURE THE CARPETING TO THE FLOOR PAN MAY HAVE ACCIDENTALLY PENETRATED THE TOP OF THE FUEL TANK. THIS WOULD RESULT IN A SLIGHT FUEL LEAK.
11,500 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSPECT VEHICLES FOR PENETRATION OF THE FUEL TANK BY CARPET FASTENERS. ANY LEAKING FUEL TANKS WILL BE REPLACED AND THE FLOOR PAN WILL BE SEALED, WITHOUT CHARGE TO OWNERS.
80V141000 Oct 24, 1980
FORD LTD (1981) — STRUCTURE:BODY:BUMPERS
THE INVOLVED VEHICLES WERE PRODUCED WITHOUT SURLYN-COATED FOIL INSULATORS BETWEEN THE ISOLATOR AND BRACKET ASSEMBLIES AND THE REAR BUMPER REINFORCEMENTS. AN EPOXY COATING WAS ALSO OMITTED FROM THE BRACKET ASSEMBLIES. WHEN EXPOSED TO THE CORROSIVE ACTION OF ROAD SALT, THE ALUMINUM REAR BUMPER REINFORCEMENT COULD EXPERIENCE GALVONIC CORROSION AT THE ATTACHMENT SURFACES. THIS WOULD REDUCE THE STRENGT...
600 vehicles affected Manufacturer: FORD MOTOR COMPANY
Remedy: DEALER WILL INSPECT REAR BUMPER ATTACHMENT COMPONENTS AND REPLACE THEM WITHOUT CHARGE, IF NECESSARY.
Previous 1 2 3 4 5 ... 30 31 32 ... 36 37 Next