NHTSA Campaign 99V219000
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
Issued by FORD MOTOR COMPANY · Reported Aug 12, 1999 · 245,300 vehicles affected
What's wrong
VEHICLE DESCRIPTION: GASOLINE AND DIESEL ENGINE PICKUP TRUCKS EQUIPPED WITH 8 FOOT BEDS, DO NOT FULLY SATISFY THE REQUIREMENTS OF FMVSS NO. 301, "FUEL SYSTEM INTEGRITY." THE FUEL TANK FRONT STRAP ISOLATOR MAY NOT BE PROPERLY POSITIONED WHICH COULD RESULT IN THE STRAP CUTTING THE TANK DURING A 30 MPH FRONT BARRIER TEST, RESULTING IN FUEL SPILLAGE.
Consequence
DURING THE SUBSEQUENT STATIC ROLLOVER TEST, FUEL SPILLAGE EXCEEDED THE SPECIFIED RATE, INCREASING THE RISK OF A FIRE.
Remedy
DEALERS WILL REPOSITION THE FRONT STRAP ISOLATOR.
Vehicles affected by this recall
| Make | Model | Year | Units |
|---|---|---|---|
| FORD | F-250 | 1999 | 245,300 |
| FORD | F-250 | 2000 | 245,300 |
| FORD | F-350 | 1999 | 245,300 |
| FORD | F-350 | 2000 | 245,300 |
Source: NHTSA Campaign 99V219000 on nhtsa.gov. To check the current repair status for a specific vehicle, use our free VIN decoder.