NHTSA Campaign 24E012000
EQUIPMENT
Issued by Carrier Corporation · Reported Feb 9, 2024 · 1,945 vehicles affected
What's wrong
Carrier Corporation (Carrier) is recalling PowerLINE RG15 and UG15 series 24 CARB-compliant generator sets (Models 69RG15-120W-24, 69UG15-050S-24, 69UG15-068S-24, and 69UG15-080S-24). The Diesel Oxidation Catalyst (DOC) may overheat.
Consequence
An overheated DOC can melt the shell, cover, and surrounding parts, increasing the risk of a fire.
Remedy
Owners of vehicles that are equipped with these generator sets are advised not to operate these vehicles until root-cause investigation is complete. Dealers will install a safety circuit, free of charge. Owner notification letters were mailed March 13, 2024. Owners may contact Carrier Corporation customer service at 1-800-668-6283.
Vehicles affected by this recall
| Make | Model | Year | Units |
|---|---|---|---|
| CARRIER TRANSICOLD | RG GENSET | 1,945 | |
| CARRIER TRANSICOLD | UG GENSET | 1,945 |
Source: NHTSA Campaign 24E012000 on nhtsa.gov. To check the current repair status for a specific vehicle, use our free VIN decoder.