NHTSA Campaign 18V036000
ELECTRICAL SYSTEM: INSTRUMENT CLUSTER/PANEL
Issued by Altec Industries Inc. · Reported Jan 11, 2018 · 122 vehicles affected
What's wrong
Altec Industries Inc. (Altec) is recalling certain 2014-2017 Altec AC40-152S Cranes. On the affected cranes, the electronic Load Moment and Area Protection (LMAP) may display incorrect load chart values.
Consequence
Using an incorrect chart value could lead to unit instability or loss of load control increasing the risk of death of serious injury.
Remedy
Altec will notify owners, and dealers will update the LMAP software, as necessary, free of charge. The recall began on February 5, 2018. Owners may contact Altec at 1-205-991-7733. Altec's number for this recall is CSN 673.
Vehicles affected by this recall
| Make | Model | Year | Units |
|---|---|---|---|
| ALTEC | AC40-152S | 2014 | 122 |
| ALTEC | AC40-152S | 2015 | 122 |
| ALTEC | AC40-152S | 2016 | 122 |
| ALTEC | AC40-152S | 2017 | 122 |
Source: NHTSA Campaign 18V036000 on nhtsa.gov. To check the current repair status for a specific vehicle, use our free VIN decoder.