NHTSA Campaign 05V153000

ELECTRICAL SYSTEM

Issued by ROAD RESCUE, INC. · Reported Apr 15, 2005 · 216 vehicles affected

What's wrong

ON CERTAIN AMBULANCES EQUIPPED WITH THE "SMART DISPLAY" ELECTRICAL SYSTEM CONTAINING FIELD-EFFECT TRANSISTOR (FET) OUTPUT BOARDS, THE POWER DISTRIBUTION PANEL FOR THE SMART DISPLAY ARE EQUIPPED WITH TYPE 1 CIRCUIT PROTECTION. THIS ALLOWS THE BOARD TO SHUT DOWN IF AN OVER-HEATING CONDITION OR AN OVER CURRENT CONDITION IS DETECTED. AS THE BOARD COOLS DOWN, IT COMES BACK ON, ALLOWING THE BOARD TO CONTINUALLY CYCLE LEADING TO POSSIBLE FAILURE.

Consequence

THE BOARDS CAN POSSIBLY OVERHEAT OR MELT DOWN, WHICH COULD CAUSE A FIRE.

Remedy

DEALERS WILL INSTALL A NEW TRANSISTOR FET BOARD THAT CONTAINS TYPE 2 CIRCUIT PROTECTION FREE OF CHARGE. THE RECALL BEGAN ON SEPTEMBER 6, 2005. OWNERS MAY CONTACT ROAD RESCUE AT 1-800-328-3804.

Vehicles affected by this recall

Make Model Year Units
ROAD RESCUE AMBULANCE 2002 216
ROAD RESCUE AMBULANCE 2003 216
ROAD RESCUE AMBULANCE 2004 216
ROAD RESCUE AMBULANCE 2005 216

Source: NHTSA Campaign 05V153000 on nhtsa.gov. To check the current repair status for a specific vehicle, use our free VIN decoder.