NHTSA Campaign 00V052000

EQUIPMENT:ELECTRICAL

Issued by WINNEBAGO INDUSTRIES, INC. · Reported Feb 24, 2000 · 235 vehicles affected

What's wrong

VEHICLE DESCRIPTION: MOTOR HOMES. THESE MOTOR HOMES MAY CONTAIN A GENERATOR WITH AN IMPROPERLY SIZED BREAKER FOR ITS INTENDED APPLICATION. A 30-AMP CIRCUIT BREAKER IS INSTALLED WHERE A 20-AMP CIRCUIT BREAKER SHOULD BE. THIS BREAKER PROTECTS THE CIRCUIT THAT GOES TO A CENTRAL AIR CONDITIONING UNIT.

Consequence

IF AN OVERLOAD WERE TO OCCUR TO THE CIRCUIT, IT COULD IGNITE THE INSULATION AND RESULT IN BODILY INJURY AND/OR PROPERTY DAMAGE.

Remedy

DEALERS WILL INSPECT THE CIRCUIT BREAKERS IN THE GENERATOR AND, IF NECESSARY, REPLACE THE BREAKER.