"ONEOK NGL PIPELINE, LLC"

hazardous_liquid Incident — — July 7, 2019

Incident Information

Incident DateJuly 7, 2019
Operator"ONEOK NGL PIPELINE, LLC"
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates42.83009, -104.33393

Cause

CauseEQUIPMENT FAILURE
SubcauseNON-THREADED CONNECTION FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$0
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

"ON JULY 7, 2019 AT APPROXIMATELY 16:24, A ONEOK EMPLOYEE RECEIVED A CALL FROM A THIRD-PARTY CONTRACTOR REPORTING A VAPOR CLOUD AT THE LUSK PUMP STATION. EMPLOYEE RESPONDED TO ONEOK'S LUSK PUMP STATION AT APPROXIMATELY 17:07 AND DETERMINED THAT A HAMMER UNION ON A TEMPORARY FILTER VESSEL ON THE NIOBRARA PIG TRAP WAS LEAKING. THE PIPELINE SEGMENT WAS ISOLATED AND BLOWN DOWN FOR INSPECTION AT APPROXIMATELY 17:09. WHEN THE HAMMER UNION WAS INSPECTED, AN O-RING WAS FOUND TO BE SPLIT CAUSING THE RELEASE. THE O-RING WAS REPLACED, LINE WAS PURGED, VERIFIED TO BE LEAK FREE, AND PUT BACK IN SERVICE AT APPROXIMATELY 01:30 ON JULY 8, 2019. ONE (1) BARREL OF PRODUCT (NGL) WAS ESTIMATED TO BE RELEASED."