PLAINS PIPELINE, L.P.

hazardous_liquid Incident —

Incident Information

Report Date
OperatorPLAINS PIPELINE, L.P.
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates36.24405, -98.77832

Cause

CauseINCORRECT OPERATION
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

APPROXIMATELY 425 BARRELS OF CRUDE OIL WERE RELEASED WITHIN FACILITY BOUNDARIES FROM A CHECK VALVE ON MANIFOLD PIPING BETWEEN THE TANK AND BOOSTER PUMP. THIS SECTION OF MANIFOLD PIPING WAS BEING ISOLATED FROM THE SYSTEM AS PART OF UNRELATED MAINTENANCE AT THE STATION. DURING ISOLATION ACTIVITIES, AN EMPLOYEE FAILED TO IDENTIFY A CHECK VALVE BETWEEN THE TANK AND BOOSTER PUMP WHEN PERFORMING LOCK-OUT/TAG-OUT TASKS. THIS RESULTED IN CRUDE OIL FILLING THE SEGMENT BETWEEN THE CHECK VALVE AND BOOSTER PUMP AS TEMPERATURES FELL, AND RELEASING FROM THE CHECK VALVE FROM THERMAL PRESSURE AS TEMPERATURES ROSE. THEREFORE, INCORRECT OPERATION WAS DETERMINED TO BE THE CAUSE OF THIS RELEASE DUE TO AN IMPROPER VALVE BEING CLOSED. TO PREVENT FUTURE RELEASES, PLAINS IS REVIEWING THE LOCK-OUT/TAG OUT SPECIFICATION TO DETERMINE IF ANY REVISIONS OR CLARIFICATIONS SHOULD BE MADE AS A RESULT OF THIS RELEASE.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in