"MARKWEST OKLAHOMA GAS COMPANY, LLC"

gas_transmission Incident — — May 9, 2016

Incident Information

Incident DateMay 9, 2016
Operator"MARKWEST OKLAHOMA GAS COMPANY, LLC"
CommodityNATURAL GAS
Pipeline Typegas_transmission

Location

State
Coordinates33.98067, -96.00694

Cause

CauseNATURAL FORCE DAMAGE
SubcauseOTHER NATURAL FORCE DAMAGE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$0
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

"A TORNADO AFFECTED THE MEASUREMENT SKID AND BUILDING AT A DELIVERY POINT. THE DEBRIS IMPACT CAUSED A PLUG TO RELEASE GAS. THE SECTION WAS ISOLATED AND THE PLUG REPLACED. AFTER FURTHER INVESTIGATION THE NEXT DAY, THE COST OF THE MEASUREMENT BUILDING DAMAGE WAS ESTIMATED AT GREATER THAN $50,000 WHICH QUALIFIES AS AN INCIDENT AND THE TELEPHONIC NRC REPORT WAS FILED."