2000 TIFFIN ALLEGRO

5 recalls, 22 complaints - 13 TSBs

11V082000 Feb 8, 2011
EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
Defect Description
TIFFIN MOTORHOMES IS RECALLING CERTAIN RECREATIONAL VEHICLES EQUIPPED WITH 1200-SERIES NORCOLD REFRIGERATORS. THE POPULATION OF REFRIGERATORS BEING ADDRESSED CONTAINS EITHER A SENSING ALGORITHM OR THERMAL SWITCH TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED IN ORDER TO P... Read more
Consequence
THE SENSING ALGORITHM OR THERMAL SWITCH INSTALLED TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED DUE TO A POSSIBLE HYDROGEN GAS LEAK MAY NOT SHUT OFF IN SUFFICIENT TIME TO PREVENT A FIRE.
Remedy
TIFFIN MOTORHOMES IS WORKING WITH NORCOLD TO IDENTIFY AND NOTIFY ANY AFFECTED OWNERS. OWNERS WILL BE INSTRUCTED TO CONTACT NORCOLD DEALERS TO RECEIVE THE REMEDY FREE OF CHARGE. PLEASE SEE NORCOLD'S DEFECT REPORT 10E-049 FOR ADDITIONAL INFORMATION. THE SAFETY RECALL BEGAN ON FEBRUARY 17, 2011. OW... Read more
10,683 vehicles affected
Manufacturer: TIFFIN MOTORHOMES, INC.
10V585000 Nov 22, 2010
EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
Defect Description
TIFFIN IS RECALLING CERTAIN RECREATIONAL VEHICLES EQUIPPED WITH 1200-SERIES NORCOLD REFRIGERATORS. THE POPULATION OF REFRIGERATORS BEING ADDRESSED CONTAINS EITHER A SENSING ALGORITHM OR THERMAL SWITCH TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED IN ORDER TO PREVENT A PO... Read more
Consequence
THE SENSING ALGORITHM OR THERMAL SWITCH INSTALLED TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED DUE TO A POSSIBLE HYDROGEN GAS LEAK MAY NOT SHUT OFF IN SUFFICIENT TIME TO PREVENT A FIRE.
Remedy
TIFFIN IS WORKING WITH NORCOLD TO IDENTIFY AND NOTIFY ANY AFFECTED OWNERS. OWNERS WILL BE INSTRUCTED TO CONTACT NORCOLD DEALERS TO RECEIVE THE REMEDY FREE OF CHARGE. PLEASE SEE NORCOLD'S DEFECT REPORT 10E-049 FOR ADDITIONAL INFORMATION. THE RECALL BEGAN ON FEBRUARY 17, 2011. OWNERS MAY CONTACT N... Read more
2,717 vehicles affected
Manufacturer: TIFFIN MOTORHOMES, INC.
07V517000 Nov 5, 2007
EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
Defect Description
ON CERTAIN MOTOR HOMES EQUIPPED WITH A TWO-DOOR REFRIGERATOR MANUFACTURED BY THE DOMETIC CORPORATION, THESE REFRIGERATORS MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION COULD BE RELEASED INTO AN AREA WHERE AN IGNITION SOURCE (GAS FLAME) IS PRESENT.
Consequence
RELEASE OF COOLANT UNDER CERTAIN CONDITIONS COULD IGNITE AND RESULT IN A FIRE.
Remedy
TIFFIN MOTORHOMES WILL BE WORKING WITH DOMETIC IN ORDER TO REPAIR THESE REFRIGERATORS (PLEASE SEE 06E076). DOMETIC WILL REPAIR THESE REFRIGERATORS BY INSTALLING A SECONDARY BURN HOUSING, A THERMAL FUSE, AND A MELT FUSE FREE OF CHARGE. DOMETIC HAS RETAINED STERICYCLE INC. TO MANAGE THIS CAMPAIGN. ... Read more
11,438 vehicles affected
Manufacturer: TIFFIN MOTORHOMES, INC.
03V149000 Apr 14, 2003
SERVICE BRAKES, HYDRAULIC:BRAKE FLUID LOW WARNING: LAMP
Defect Description
CERTAIN MOTOR HOME CHASSIS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 105, "HYDRAULIC AND ELECTRIC BRAKE SYSTEMS." THE BRAKE SYSTEM WARNING INDICATOR MAY NOT FUNCTION AS REQUIRED BY STANDARD.
Consequence
IN SOME OF THE AFFECTED VEHICLES, THE BRAKE SYSTEM WARNING INDICATOR WILL NOT ILLUMINATE WHEN THE IGNITION IS IN THE START POSITION OR FOR A LOW BRAKE FLUID CONDITION, IF THE BODY BUILDER RELIED SOLELY UPON FORD'S IVM COMPLIANCE STATEMENT FOR THE BRAKE SYSTEM WARNING INDICATOR.
Remedy
DEALERS WILL REPAIR THE BRAKE WARNING LAMP CIRCUIT. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT TIFFIN AT 1-256-356-8661.
1,174 vehicles affected
Manufacturer: TIFFIN MOTOR HOMES
01V097008 Jun 22, 2001
SEAT BELTS:FRONT:BUCKLE ASSEMBLY
Defect Description
VEHICLE DESCRIPTION: MOTOR HOMES EQUIPPED WITH SAFETY BELT ASSEMBLIES PRODUCED BY AM-SAFE. ON SOME SEAT BELTS, THE BUCKLE AND CONNECTOR MAY UNLATCH DURING A COLLISION.
Consequence
SERIOUS INJURY OR DEATH COULD OCCUR IF THE VEHICLE OCCUPANT IS NOT PROPERLY RESTRAINED.
Remedy
AM-SAFE NOTIFIED TIFFIN'S CUSTOMERS TO RETURN THEIR VEHICLE TO AN AUTHORIZED DEALER TO HAVE THE SEAT BELTS REPAIRED FREE OF CHARGE. OWNER NOTIFICATION BEGAN AUGUST 31, 2000. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WI... Read more
955 vehicles affected
Manufacturer: TIFFIN MOTOR HOMES

Complaint Statistics

22 total complaints 18 injuries

Top Reported Components

ComponentComplaints
ELECTRICAL SYSTEM3
TIRES:SIDEWALL2
EQUIPMENT:RECREATIONAL VEHICLE/TRAILER2
FUEL SYSTEM, GASOLINE:CARBURETOR SYSTEM1
SEAT BELTS:FRONT:BUCKLE ASSEMBLY1
STRUCTURE1
EQUIPMENT1
VISIBILITY:REARVIEW MIRRORS/DEVICES1
LATCHES/LOCKS/LINKAGES:DOORS:LATCH1
VISIBILITY:WINDSHIELD WIPER/WASHER1
ELECTRICAL SYSTEM Oct 29, 2025
Incident date: Oct 21, 2025
See attached document for complaint.
PARKING BRAKE Oct 7, 2006
Incident date: Sep 18, 2006
2000 CHEVY P-30 CHASSIS AUTO PARK THE "AUTO PARK/EMERGENCY BRAKE" SYSTEM FAILS. THIS CAN HAPPEN GOING DOWN THE ROAD AT WHAT EVER SPEED YOU ARE DRIVING OR SITTING STILL. *NM
SERVICE BRAKES, HYDRAULIC:POWER ASSIST:VACUUM Feb 18, 2005
Incident date: Feb 13, 2005
AFTER PULLING ONTO THE INTERSTATE THE VEHICLE SHUT DOWN. THERE WAS NO STEERING AND NO BRAKES. CONSUMER WAS ABLE TO STOP THE VEHICLE, AND THERE WAS FLUID ON THE GROUND. THE VEHICLE WAS TOWED, AND THE POWER BOOSTER HAD TO BE REPLACED.*AK
TIRES:TREAD/BELT Sep 10, 2004
Incident date: Sep 8, 2004
WHILE DRIVING 63 MPH RIGHT REAR INNER TIRE EXPERIENCED A BLOWOUT ON A TIFFIN, ALLEGRO BUS 2000 RV WITH TWO ADULTS IN IT. ORIGINAL EQUIPMENTS, TIRE SIZE 255/80R22.5, DOT # B6H6AK3X0100. MANUFACTURER WAS NOT NOTIFIED. *AK THE CONSUMER REPLACED ALL FOUR TIRES. *TC
TIRES:SIDEWALL Aug 4, 2004
Incident date: Mar 29, 2004
WE EXPERIENCED A TIRE BLOW OUT ON OUR 2000 ALLEGRO BUS ON THE BACK RIGHT OUTSIDE TIRE. WE GOT THE TIRE REPAIRED AND DROVE ABOUT 20 MILES AND HAD ANOTHER BLOW OUT ON THE FRONT RIGHT SIDE. MICHELINE DOES NOT ADMIT TO A PROBLEM, BUT THE WEIGHT AND TIRE PRESSURE WERE CORRECT FOR THE TIRES. THE TIRES A... Read more
ELECTRICAL SYSTEM Jul 10, 2001
Incident date: Nov 10, 2000
WHILE DRIVING 30MPH OVERHEAD BUNK BED FELL. ALSO, BUNK BED WAS HELD UP BY TWO PLASTIC LATCHES. CONTACTED DEALER, AND DEALER REPLACED THEM WITH METAL PINS TO HOLD BED UP.*AK CONSUMER HAS SEVERAL COMPLAINTS REGARDING THIS VEHICLE, HERE ARE A FEW EXPAMPLES OF SOME OF THE COMPLAINTS. SLIDING WINDOW R... Read more
2 injured
ELECTRICAL SYSTEM:ALTERNATOR/GENERATOR/REGULATOR Jul 10, 2001
Incident date: Dec 10, 2000
BRAKE LIGHTS/REFRIGERATOR, AND GENERATOR HAD TO BE REWIRED. BRAKE LIGHTS DIDN'T WORK AT ALL. REFRIGERATOR AND GENERATOR WERE REWIRED WRONGLY. ALSO, POWER TO GENERATOR WIRES WERE SPLICED AND NOT COVERED. CONTACTED DEALER. *AK OVERHEAD BUNK BED FELL ON THE DRIVER AND PASSENGER WHILE DRIVING 35MPH... Read more
EQUIPMENT:RECREATIONAL VEHICLE/TRAILER Jul 10, 2001
Incident date: Dec 10, 2000
BRAKE LIGHTS/REFRIGERATOR, AND GENERATOR HAD TO BE REWIRED. BRAKE LIGHTS DIDN'T WORK AT ALL. REFRIGERATOR AND GENERATOR WERE REWIRED WRONGLY. ALSO, POWER TO GENERATOR WIRES WERE SPLICED AND NOT COVERED. CONTACTED DEALER. *AK OVERHEAD BUNK BED FELL ON THE DRIVER AND PASSENGER WHILE DRIVING 35MPH... Read more
ELECTRICAL SYSTEM:WIRING Jul 10, 2001
Incident date: Dec 10, 2000
BRAKE LIGHTS/REFRIGERATOR, AND GENERATOR HAD TO BE REWIRED. BRAKE LIGHTS DIDN'T WORK AT ALL. REFRIGERATOR AND GENERATOR WERE REWIRED WRONGLY. ALSO, POWER TO GENERATOR WIRES WERE SPLICED AND NOT COVERED. CONTACTED DEALER. *AK OVERHEAD BUNK BED FELL ON THE DRIVER AND PASSENGER WHILE DRIVING 35MPH... Read more
ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS Jul 10, 2001
Incident date: Dec 10, 2000
BRAKE LIGHTS/REFRIGERATOR, AND GENERATOR HAD TO BE REWIRED. BRAKE LIGHTS DIDN'T WORK AT ALL. REFRIGERATOR AND GENERATOR WERE REWIRED WRONGLY. ALSO, POWER TO GENERATOR WIRES WERE SPLICED AND NOT COVERED. CONTACTED DEALER. *AK OVERHEAD BUNK BED FELL ON THE DRIVER AND PASSENGER WHILE DRIVING 35MPH... Read more
ELECTRICAL SYSTEM Jul 10, 2001
Incident date: Dec 10, 2000
BRAKE LIGHTS/REFRIGERATOR, AND GENERATOR HAD TO BE REWIRED. BRAKE LIGHTS DIDN'T WORK AT ALL. REFRIGERATOR AND GENERATOR WERE REWIRED WRONGLY. ALSO, POWER TO GENERATOR WIRES WERE SPLICED AND NOT COVERED. CONTACTED DEALER. *AK OVERHEAD BUNK BED FELL ON THE DRIVER AND PASSENGER WHILE DRIVING 35MPH... Read more
VISIBILITY:WINDSHIELD Jul 10, 2001
Incident date: Nov 10, 2000
WHILE DRIVING 30MPH OVERHEAD BUNK BED FELL. ALSO, BUNK BED WAS HELD UP BY TWO PLASTIC LATCHES. CONTACTED DEALER, AND DEALER REPLACED THEM WITH METAL PINS TO HOLD BED UP.*AK CONSUMER HAS SEVERAL COMPLAINTS REGARDING THIS VEHICLE, HERE ARE A FEW EXPAMPLES OF SOME OF THE COMPLAINTS. SLIDING WINDOW R... Read more
2 injured
SEAT BELTS:FRONT:ANCHORAGE Jul 10, 2001
Incident date: Nov 10, 2000
WHILE DRIVING 30MPH OVERHEAD BUNK BED FELL. ALSO, BUNK BED WAS HELD UP BY TWO PLASTIC LATCHES. CONTACTED DEALER, AND DEALER REPLACED THEM WITH METAL PINS TO HOLD BED UP.*AK CONSUMER HAS SEVERAL COMPLAINTS REGARDING THIS VEHICLE, HERE ARE A FEW EXPAMPLES OF SOME OF THE COMPLAINTS. SLIDING WINDOW R... Read more
2 injured
VISIBILITY:WINDSHIELD WIPER/WASHER Jul 10, 2001
Incident date: Nov 10, 2000
WHILE DRIVING 30MPH OVERHEAD BUNK BED FELL. ALSO, BUNK BED WAS HELD UP BY TWO PLASTIC LATCHES. CONTACTED DEALER, AND DEALER REPLACED THEM WITH METAL PINS TO HOLD BED UP.*AK CONSUMER HAS SEVERAL COMPLAINTS REGARDING THIS VEHICLE, HERE ARE A FEW EXPAMPLES OF SOME OF THE COMPLAINTS. SLIDING WINDOW R... Read more
2 injured
LATCHES/LOCKS/LINKAGES:DOORS:LATCH Jul 10, 2001
Incident date: Nov 10, 2000
WHILE DRIVING 30MPH OVERHEAD BUNK BED FELL. ALSO, BUNK BED WAS HELD UP BY TWO PLASTIC LATCHES. CONTACTED DEALER, AND DEALER REPLACED THEM WITH METAL PINS TO HOLD BED UP.*AK CONSUMER HAS SEVERAL COMPLAINTS REGARDING THIS VEHICLE, HERE ARE A FEW EXPAMPLES OF SOME OF THE COMPLAINTS. SLIDING WINDOW R... Read more
2 injured
VISIBILITY:REARVIEW MIRRORS/DEVICES Jul 10, 2001
Incident date: Nov 10, 2000
WHILE DRIVING 30MPH OVERHEAD BUNK BED FELL. ALSO, BUNK BED WAS HELD UP BY TWO PLASTIC LATCHES. CONTACTED DEALER, AND DEALER REPLACED THEM WITH METAL PINS TO HOLD BED UP.*AK CONSUMER HAS SEVERAL COMPLAINTS REGARDING THIS VEHICLE, HERE ARE A FEW EXPAMPLES OF SOME OF THE COMPLAINTS. SLIDING WINDOW R... Read more
2 injured
EQUIPMENT Jul 10, 2001
Incident date: Nov 10, 2000
WHILE DRIVING 30MPH OVERHEAD BUNK BED FELL. ALSO, BUNK BED WAS HELD UP BY TWO PLASTIC LATCHES. CONTACTED DEALER, AND DEALER REPLACED THEM WITH METAL PINS TO HOLD BED UP.*AK CONSUMER HAS SEVERAL COMPLAINTS REGARDING THIS VEHICLE, HERE ARE A FEW EXPAMPLES OF SOME OF THE COMPLAINTS. SLIDING WINDOW R... Read more
2 injured
STRUCTURE Jul 10, 2001
Incident date: Nov 10, 2000
WHILE DRIVING 30MPH OVERHEAD BUNK BED FELL. ALSO, BUNK BED WAS HELD UP BY TWO PLASTIC LATCHES. CONTACTED DEALER, AND DEALER REPLACED THEM WITH METAL PINS TO HOLD BED UP.*AK CONSUMER HAS SEVERAL COMPLAINTS REGARDING THIS VEHICLE, HERE ARE A FEW EXPAMPLES OF SOME OF THE COMPLAINTS. SLIDING WINDOW R... Read more
2 injured
EQUIPMENT:RECREATIONAL VEHICLE/TRAILER Jul 10, 2001
Incident date: Nov 10, 2000
WHILE DRIVING 30MPH OVERHEAD BUNK BED FELL. ALSO, BUNK BED WAS HELD UP BY TWO PLASTIC LATCHES. CONTACTED DEALER, AND DEALER REPLACED THEM WITH METAL PINS TO HOLD BED UP.*AK CONSUMER HAS SEVERAL COMPLAINTS REGARDING THIS VEHICLE, HERE ARE A FEW EXPAMPLES OF SOME OF THE COMPLAINTS. SLIDING WINDOW R... Read more
2 injured
TIRES:SIDEWALL Feb 12, 2001
THE TIRES THAT CAME WITH THE VEHICLE (MICHELIN 235/80 XRV ON 22.5 INCH RIMS) WERE PROPERLY INFLATED WHEN THE INNER LEFT REAT TIRE BLEWOUT DUE TO A DEFECT IN THE SIDEWALL, CAUSING DAMAGE TO THE FENDER WELL COVER. NLM
SEAT BELTS:FRONT:BUCKLE ASSEMBLY Jan 25, 2001
RECEIVED RECALL 00E048000 IN MAIL. CONTACTED MOTOR HOME DEALERSHIP. WAS INFORMED THAT NO PARTS WERE AVAILABLE FOR REPAIRS OF SEAT BELT BUCKLES.*AK
FUEL SYSTEM, GASOLINE:CARBURETOR SYSTEM Nov 20, 2000
Incident date: Sep 19, 2000
WHILE DRIVING IN THE RAIN, VEHICLE'S ENGINE STARTED TO MISS FIRE AND AT TIMES IT COMPLETELY SHUT OFF AND WOULD DROP 5-10 MPH OF SPEED, DEALER FOUND THE AIR FILTER TO BE COMPLETELY SATURATED WITH WATER, THE FILTER HOUSING AND INTAKE TUBE WERE ALSO FILLED WITH LARGE QUANTITIES OF WATER, THE DEALER REP... Read more

Technical Service Bulletins, 2000 TIFFIN ALLEGRO

13 manufacturer communications from 8 unique bulletins. TSBs describe known problems and recommended fixes from the manufacturer.

Most Affected Components

ComponentBulletins
350000 EQUIPMENT2
351000 EQUIPMENT:RECREATIONAL VEHICLE/TRAILER2
353500 EQUIPMENT:ELECTRICAL:NAVIGATIONAL SYSTEM(GLOBAL POSITIONING SYSTEM)1
355200 EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL1
356000 EQUIPMENT ADAPTIVE/MOBILITY1
351150 EQUIPMENT:RECREATIONAL VEHICLE/TRAILER:LPG SYSTEMS:WATER HEATER1
160000 STRUCTURE1
357100 EQUIPMENT:APPLIANCE:AIR CONDITIONER1
SB-36 Nov 24, 2015
357100 EQUIPMENT:APPLIANCE:AIR CONDITIONER
TIFFIN MOTORHOMES: TSB CONTAINS NOTIFICATION OF OWNER LETTER. SELECT DOCUMENT SEARCH BUTTON BELOW. TWO SCREWS WAS NOT INSTALLED ON THE AIR CONDITION UNITS ON THE ROOF. *TA UPDATED 11/24/15. *PE
16AWG Jul 16, 2015
113100 ELECTRICAL SYSTEM:STARTER ASSEMBLY:SOLENOID
RV: INSTRUCTIONS ON HOW TO INSTALL THE CHARGE SOLENOID WIRING IN A RV OR VEHICLE. *TA
16AWG Jul 16, 2015
114000 ELECTRICAL SYSTEM:WIRING
RV: INSTRUCTIONS ON HOW TO INSTALL THE CHARGE SOLENOID WIRING IN A RV OR VEHICLE. *TA
16AWG Jul 16, 2015
114300 ELECTRICAL SYSTEM:WIRING: REAR COMPARTMENT/TRUNK
RV: INSTRUCTIONS ON HOW TO INSTALL THE CHARGE SOLENOID WIRING IN A RV OR VEHICLE. *TA
C85-C86AC Jun 26, 2015
350000 EQUIPMENT
TIFFIN MOTORHOMES: TSB CONTAINS NOTIFICATION OF OWNER LETTER. SELECT DOCUMENT SEARCH BUTTON BELOW. ALL TIFFIN MOTORHOMES WILL BE INSTALLING 2 BACK SCREWS OF THE C85 AND C86 A/C'S TO THE ROOF OF ALL TIFFIN MOTORHOMES. *TA.
SB-41 Mar 12, 2014
160000 STRUCTURE
TIFFIN MOTORHOMES: TSB CONTAINS NOTIFICATION OF OWNER LETTER. SELECT DOCUMENT SEARCH BUTTON BELOW. THE PROCEDURE TO SEAL UNDER THE F-TRIM ON ALL ALLEGROS. *JS UPDATED 6/29/15. *TA
WI-196 Mar 12, 2013
351000 EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
TIFFIN MOTORHOMES: TSB CONTAINS NOTIFICATION OF OWNER LETTER. SELECT DOCUMENT SEARCH BUTTON BELOW. SOME TIFFIN MOTORHOMES NEED DRIVER/PASSENGER SEATBELTS TIGHTENED ON THE MOUNTING BRACKETS LOCATED ON THE DRIVER/PASSENGER SIDEWALL. *TA
SB-23 Jun 6, 2008
353500 EQUIPMENT:ELECTRICAL:NAVIGATIONAL SYSTEM(GLOBAL POSITIONING SYSTEM)
TIFFIN MOTORHOMES SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. A WIRE IS NOT HOOKED UP AND NEEDS TO BE. THE NAVIGATIONAL SYSTEM WILL WORK UNTIL ITS PROGRAM FOR A DESTINATION AND GET THE PATH TO THE DESTINATION. CSC LET
SB-20 Mar 29, 2008
351150 EQUIPMENT:RECREATIONAL VEHICLE/TRAILER:LPG SYSTEMS:WATER HEATER
TIFFIN MOTORHOMES: THERE IS A POTENTIAL PROBLEM WITH THE WATER HEATER BY PASS IN YOUR UNIT. THERE IS A POSSIBILITY IT WAS INCORRECTLY PLUMBED. CSC LETTER WAS RECEIVED. *PE
SB-21 Mar 18, 2008
350000 EQUIPMENT
TIFFIN MOTORHOMES SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. SWITCH BOX GROUNDING LUG. THE TAP SCREW IS NOT TIGHT ENOUGH. THIS COULD CAUSE PROBLEMS AT THE LOAD CENTER CAUSING A LOSS OF GROUND. CSC LETTER WAS RECEIVE
SB-21 Mar 18, 2008
351000 EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
TIFFIN MOTORHOMES SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. SWITCH BOX GROUNDING LUG. THE TAP SCREW IS NOT TIGHT ENOUGH. THIS COULD CAUSE PROBLEMS AT THE LOAD CENTER CAUSING A LOSS OF GROUND. CSC LETTER WAS RECEIVE
SB-21 Mar 18, 2008
355200 EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL
TIFFIN MOTORHOMES SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. SWITCH BOX GROUNDING LUG. THE TAP SCREW IS NOT TIGHT ENOUGH. THIS COULD CAUSE PROBLEMS AT THE LOAD CENTER CAUSING A LOSS OF GROUND. CSC LETTER WAS RECEIVE
SB-21 Mar 18, 2008
356000 EQUIPMENT ADAPTIVE/MOBILITY
TIFFIN MOTORHOMES SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. SWITCH BOX GROUNDING LUG. THE TAP SCREW IS NOT TIGHT ENOUGH. THIS COULD CAUSE PROBLEMS AT THE LOAD CENTER CAUSING A LOSS OF GROUND. CSC LETTER WAS RECEIVE

NHTSA Safety Investigations, TIFFIN ALLEGRO

Investigations opened by NHTSA into potential safety defects. These are separate from recalls and may or may not result in a recall.

EA86009 Opened: Mar 10, 1986 , Closed: Oct 1, 1987
EA, Closed , Model Year: 1986
OVERLOAD
SUMMARY OF INFORMATION FROM MANUFACTURER:TIFFIN USES THE CHEVROLETASTRO MINI VAN FOR 21 FOOT MICRO-MINI ALLEGRO MOTORHOME.TIFFINREPLACES THE REAR AXLE OF THE STOCK ASTRO WITH A CHEVROLET C-10LIGHT TRUCK REAR AXLE ASSEMBLY TO INCREASE ITS WEIGHT RATING TO7,000 POUNDS. (ASTRO HAS A 5,600 POUND GVWR).A... Read more

TIFFIN ALLEGRO - All Years Overview

Complete safety history for the TIFFIN ALLEGRO across all model years (1979, 2023).

137 Total Recalls
208 Total Complaints
1 Investigations
3 Reported Crashes
13 Reported Fires
0 Reported Deaths

TIFFIN ALLEGRO - Year by Year

Compare recalls and complaints across model years. Click any year to see full details.

Year Recalls Complaints
2024 0 2 View
2023 2 12 View
2022 5 4 View
2021 5 9 View
2020 2 1 View
2019 2 4 View
2018 3 5 View
2017 3 5 View
2016 3 6 View
2015 5 0 View
2014 5 5 View
2013 4 6 View
2012 3 8 View
2011 8 8 View
2010 10 4 View
2009 7 0 View
2008 7 2 View
2007 8 2 View
2006 6 3 View
2005 7 3 View
2004 8 2 View
2003 7 13 View
2002 5 23 View
2001 6 19 View
2000 (current) 5 22
1999 4 4 View
1998 3 4 View
1997 2 3 View
1996 0 4 View
1995 0 8 View
1994 0 3 View
1993 0 3 View
1992 0 1 View
1991 0 1 View
1990 0 1 View
1988 0 4 View
1986 0 1 View
1985 0 1 View
1984 0 1 View
1983 0 1 View
1980 1 0 View
1979 1 0 View

Other TIFFIN Models

Model Recalls Complaints
ALLEGRO BAY 0 0 View
ALLEGRO BREEZE 0 0 View
ALLEGRO BUS 0 0 View
ALLEGRO OPEN ROAD 0 0 View
ALLEGRO RED 0 0 View
ALLEGRO RED 360 0 0 View
BAY 0 0 View