2004 TIFFIN ALLEGRO BAY
5 recalls, 3 complaints - 13 TSBs
09V110000 Apr 3, 2009
SERVICE BRAKES, HYDRAULIC
Defect Description
NAVISTAR IS RECALLING CERTAIN MODEL YEAR MY 2001-2008 WORKHORSE W20, W21 AND W22 CHASSIS AND CERTAIN MODEL YEAR 2009 THROUGH 2011 MONACO RV ADMIRAL, ARISTA, MONARCH, AND RIPTIDE RECREATIONAL VEHICLES EQUIPPED WITH AXLES THAT INCLUDE BOSCH ZOPS OR ZOHT PIN SLIDE HYDRAULIC DISC BRAKES. WHEN COMBINED W... Read more
Consequence
THE TEMPERATURE INCREASE AT THE WHEEL END CAN EVENTUALLY LEAD TO SOFT PEDAL CONDITIONS DUE TO BRAKE FLUID BOIL, AND POSSIBLE EXTENDED STOPPING DISTANCE INCREASING THE RISK OF A CRASH.
Remedy
WORKHORSE DEALERS WILL REPLACE ALL FOUR BOSCH BRAKE CALIPER ASSEMBLIES FREE OF CHARGE. THE SAFETY RECALL BEGAN ON SEPTEMBER 16, 2010. OWNERS MAY CONTACT WORKHORSE AT 1-877-246-7731.
08V509000 Oct 7, 2008
EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
Defect Description
TIFFIN IS RECALLING 3,507 MY 2004-2007 ALLEGRO, ALLEGRO BAY AND ALLERO BUS, MY 2004-2005 PHAETON AND MY 2005-2007 ZEPHYR MOTOR HOMES EQUIPPED WITH A TWO-DOOR REFRIGERATOR MANUFACTURED BY THE DOMETIC CORPORATION. THE REFRIGERATOR MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION CO... Read more
Consequence
RELEASE OF COOLANT UNDER CERTAIN CONDITIONS COULD IGNITE AND RESULT IN A FIRE.
Remedy
TIFFIN WILL BE WORKING WITH DOMETIC IN ORDER TO REPAIR THESE REFRIGERATORS (PLEASE SEE 08E032). DOMETIC WILL REPAIR THESE REFRIGERATORS BY INSTALLING A SECONDARY BURN HOUSING, A THERMAL FUSE, AND A MELT FUSE FREE OF CHARGE. DOMETIC HAS RETAINED STERICYCLE INC. TO MANAGE THIS CAMPAIGN. STERICYCLE... Read more
07V517000 Nov 5, 2007
EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
Defect Description
ON CERTAIN MOTOR HOMES EQUIPPED WITH A TWO-DOOR REFRIGERATOR MANUFACTURED BY THE DOMETIC CORPORATION, THESE REFRIGERATORS MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION COULD BE RELEASED INTO AN AREA WHERE AN IGNITION SOURCE (GAS FLAME) IS PRESENT.
Consequence
RELEASE OF COOLANT UNDER CERTAIN CONDITIONS COULD IGNITE AND RESULT IN A FIRE.
Remedy
TIFFIN MOTORHOMES WILL BE WORKING WITH DOMETIC IN ORDER TO REPAIR THESE REFRIGERATORS (PLEASE SEE 06E076). DOMETIC WILL REPAIR THESE REFRIGERATORS BY INSTALLING A SECONDARY BURN HOUSING, A THERMAL FUSE, AND A MELT FUSE FREE OF CHARGE. DOMETIC HAS RETAINED STERICYCLE INC. TO MANAGE THIS CAMPAIGN. ... Read more
06V142000 Apr 28, 2006
ELECTRICAL SYSTEM
Defect Description
CERTAIN MOTOR HOMES BUILT ON WORKHORSE CHASSIS AND EQUIPPED WITH ACTIA CORPORATE INSTRUMENT CLUSTERS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 101, CONTROLS AND DISPLAYS, AND NO. 105, HYDRAULIC AND ELECTRIC BRAKE SYSTEMS. IF THE BRAKE FAIL INPUT FALLS BELOW A... Read more
Consequence
AT NIGHT THE INSTRUMENT CLUSTER LIGHTS MAY FAIL AND THE DRIVER MAY NOT BE ABLE TO SEE THE INSTRUMENT PANEL GAUGES AND THE BRAKE WARNING LIGHT INDICATOR WHICH COULD INCREASING THE RISK OF A CRASH.
Remedy
TIFFIN IS WORKING WITH WORKHORSE TO CONTACT THE OWNERS AND REMEDY THIS CAMPAIGN . WORKHORSE WILL REPROGRAM THE INSTRUMENT PANEL CLUSTER FREE OF CHARGE. OWNERS MAY CONTACT WORKHORSE AT 1-877-246-7731 OR TIFFIN AT 1-256-356-0205.
03V149000 Apr 14, 2003
SERVICE BRAKES, HYDRAULIC:BRAKE FLUID LOW WARNING: LAMP
Defect Description
CERTAIN MOTOR HOME CHASSIS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 105, "HYDRAULIC AND ELECTRIC BRAKE SYSTEMS." THE BRAKE SYSTEM WARNING INDICATOR MAY NOT FUNCTION AS REQUIRED BY STANDARD.
Consequence
IN SOME OF THE AFFECTED VEHICLES, THE BRAKE SYSTEM WARNING INDICATOR WILL NOT ILLUMINATE WHEN THE IGNITION IS IN THE START POSITION OR FOR A LOW BRAKE FLUID CONDITION, IF THE BODY BUILDER RELIED SOLELY UPON FORD'S IVM COMPLIANCE STATEMENT FOR THE BRAKE SYSTEM WARNING INDICATOR.
Remedy
DEALERS WILL REPAIR THE BRAKE WARNING LAMP CIRCUIT. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT TIFFIN AT 1-256-356-8661.
Complaint Statistics
3 total complaints
1 fires
Top Reported Components
| Component | Complaints |
|---|---|
| SERVICE BRAKES, HYDRAULIC | 2 |
| EQUIPMENT:RECREATIONAL VEHICLE/TRAILER | 1 |
SERVICE BRAKES, HYDRAULIC
Nov 3, 2010
Incident date: Apr 11, 2009
TL*THE CONTACT OWNS A 2004 TIFFIN ALLEGRO BAY RV. THE CONTACT RECEIVED A RECALL NOTICE. THE VEHICLE WAS TAKEN TO THE DEALER WHO REPAIRED THE VEHICLE UNDER NHTSA CAMPAIGN ID NUMBER 03V149000 (SERVICE BRAKES, HYDRAULIC SWITCHES, BRAKE WARNING). IN ADDITION TO THE REMEDY REPAIR THE FRONT AND REAR RO... Read more
SERVICE BRAKES, HYDRAULIC
Mar 24, 2009
Incident date: Jan 26, 2009
WE HAD ONE OF THE ABS SENSORS REPLACED UNDER WARRANTY THE FIRST YEAR WE OWNED OUR MOTORHOME.. NOW WHEN WE ARE OUT OF WARRANTY(2004 ALLEGRO BAY, 32,000 MILES) WE FIND OUT THAT OUR CALIPERS WERE FROZEN SO THEY WOULDN'T RELEASE, THUS CREATING A HUGE DRAG ON THE MOTORHOME. ONE OF THE CALIPERS ACTUALLY ... Read more
Fire
EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
Aug 1, 2008
Incident date: Jun 29, 2008
TL*THE CONTACT OWNS A 2004 TIFFIN ALLEGRO BAY RV. WHILE ON VACATION, THE REFRIGERATOR WOULD NOT KEEP THE FOOD COLD OR FROZEN. AFTER RETURNING HOME, A FRIEND INFORMED THE CONTACT ABOUT THE DOMETIC RECALL. HE INSPECTED HIS REFRIGERATOR AND CONFIRMED THAT THE SERIAL NUMBER MATCHED THOSE THAT WERE IN... Read more
Technical Service Bulletins, 2004 TIFFIN ALLEGRO BAY
13 manufacturer communications from 8 unique bulletins. TSBs describe known problems and recommended fixes from the manufacturer.
Most Affected Components
| Component | Bulletins |
|---|---|
| 350000 EQUIPMENT | 2 |
| 351000 EQUIPMENT:RECREATIONAL VEHICLE/TRAILER | 2 |
| 355200 EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL | 2 |
| 150000 SEAT BELTS | 1 |
| 356000 EQUIPMENT ADAPTIVE/MOBILITY | 1 |
| 351150 EQUIPMENT:RECREATIONAL VEHICLE/TRAILER:LPG SYSTEMS:WATER HEATER | 1 |
| 357100 EQUIPMENT:APPLIANCE:AIR CONDITIONER | 1 |
| 113100 ELECTRICAL SYSTEM:STARTER ASSEMBLY:SOLENOID | 1 |
Letter to dealer
Nov 10, 2017
355200 EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL
This was a letter to our dealers we sent out when we first heard of the Kidde fire extinguisher recall, even though it was still unofficial. We knew our coaches on the dealers' lots contained Kidde and could not be sold unreplaced.
SB-36
Nov 24, 2015
357100 EQUIPMENT:APPLIANCE:AIR CONDITIONER
TIFFIN MOTORHOMES: TSB CONTAINS NOTIFICATION OF OWNER LETTER. SELECT DOCUMENT SEARCH BUTTON BELOW. TWO SCREWS WAS NOT INSTALLED ON THE AIR CONDITION UNITS ON THE ROOF. *TA UPDATED 11/24/15. *PE
16AWG
Jul 16, 2015
113100 ELECTRICAL SYSTEM:STARTER ASSEMBLY:SOLENOID
RV: INSTRUCTIONS ON HOW TO INSTALL THE CHARGE SOLENOID WIRING IN A RV OR VEHICLE. *TA
16AWG
Jul 16, 2015
114000 ELECTRICAL SYSTEM:WIRING
RV: INSTRUCTIONS ON HOW TO INSTALL THE CHARGE SOLENOID WIRING IN A RV OR VEHICLE. *TA
16AWG
Jul 16, 2015
114300 ELECTRICAL SYSTEM:WIRING: REAR COMPARTMENT/TRUNK
RV: INSTRUCTIONS ON HOW TO INSTALL THE CHARGE SOLENOID WIRING IN A RV OR VEHICLE. *TA
C85-C86AC
Jun 26, 2015
350000 EQUIPMENT
TIFFIN MOTORHOMES: TSB CONTAINS NOTIFICATION OF OWNER LETTER. SELECT DOCUMENT SEARCH BUTTON BELOW. ALL TIFFIN MOTORHOMES WILL BE INSTALLING 2 BACK SCREWS OF THE C85 AND C86 A/C'S TO THE ROOF OF ALL TIFFIN MOTORHOMES. *TA.
WI-196
Mar 12, 2013
351000 EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
TIFFIN MOTORHOMES: TSB CONTAINS NOTIFICATION OF OWNER LETTER. SELECT DOCUMENT SEARCH BUTTON BELOW. SOME TIFFIN MOTORHOMES NEED DRIVER/PASSENGER SEATBELTS TIGHTENED ON THE MOUNTING BRACKETS LOCATED ON THE DRIVER/PASSENGER SIDEWALL. *TA
SB-20
Mar 29, 2008
351150 EQUIPMENT:RECREATIONAL VEHICLE/TRAILER:LPG SYSTEMS:WATER HEATER
TIFFIN MOTORHOMES: THERE IS A POTENTIAL PROBLEM WITH THE WATER HEATER BY PASS IN YOUR UNIT. THERE IS A POSSIBILITY IT WAS INCORRECTLY PLUMBED. CSC LETTER WAS RECEIVED. *PE
SB-21
Mar 18, 2008
350000 EQUIPMENT
TIFFIN MOTORHOMES SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. SWITCH BOX GROUNDING LUG. THE TAP SCREW IS NOT TIGHT ENOUGH. THIS COULD CAUSE PROBLEMS AT THE LOAD CENTER CAUSING A LOSS OF GROUND. CSC LETTER WAS RECEIVE
SB-21
Mar 18, 2008
351000 EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
TIFFIN MOTORHOMES SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. SWITCH BOX GROUNDING LUG. THE TAP SCREW IS NOT TIGHT ENOUGH. THIS COULD CAUSE PROBLEMS AT THE LOAD CENTER CAUSING A LOSS OF GROUND. CSC LETTER WAS RECEIVE
SB-21
Mar 18, 2008
355200 EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL
TIFFIN MOTORHOMES SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. SWITCH BOX GROUNDING LUG. THE TAP SCREW IS NOT TIGHT ENOUGH. THIS COULD CAUSE PROBLEMS AT THE LOAD CENTER CAUSING A LOSS OF GROUND. CSC LETTER WAS RECEIVE
SB-21
Mar 18, 2008
356000 EQUIPMENT ADAPTIVE/MOBILITY
TIFFIN MOTORHOMES SERVICE CAMPAIGN: SEE DOCUMENT SEARCH BUTTON FOR OWNER LETTER. SWITCH BOX GROUNDING LUG. THE TAP SCREW IS NOT TIGHT ENOUGH. THIS COULD CAUSE PROBLEMS AT THE LOAD CENTER CAUSING A LOSS OF GROUND. CSC LETTER WAS RECEIVE
04024
Nov 11, 2004
150000 SEAT BELTS
A DEFECT MAY EXIST IN SOME SEAT BELTS MANUFACTURED AND SENT TO TIFFIN MOTORHOMES. RECALL 04E-024 HAS BEEN ISSUED. *TT
NHTSA Safety Investigations, TIFFIN ALLEGRO BAY
Investigations opened by NHTSA into potential safety defects. These are separate from recalls and may or may not result in a recall.
PE12004
Opened: Feb 17, 2012 , Closed: Aug 17, 2012
Diminished Brake Performance
Daimler Truck has issued 12V-242.See ODI closing report for further details.The associated VOQs are: 10442468, 10442861, 10442879, and 10454022 (Model Year 2008).
PE05014
Opened: Mar 17, 2005 , Closed: Apr 19, 2005
POTENTIAL MOVEMENT OF WASHER/DRYER
IN JANUARY 2005, TIFFIN ISSUED A SERVICE BULLETIN (UNNUMBERED) ENTITLED ?SERVICE BULLETIN FOR POTENTIAL MOVEMENT OF WASHER/DRYER.?THE BULLETIN ADDRESSED THE POSSIBILITY THAT THE WASHER AND DRYER COULD MOVE UNEXPECTEDLY WHILE THE MOTORHOME IS BEING DRIVEN.DURING DISCUSSIONS WITH TIFFIN, ODI LEARNED T... Read more
TIFFIN ALLEGRO BAY - All Years Overview
Complete safety history for the TIFFIN ALLEGRO BAY across all model years (1998, 2027).
63
Total Recalls
35
Total Complaints
2
Investigations
0
Reported Crashes
3
Reported Fires
0
Reported Deaths
TIFFIN ALLEGRO BAY - Year by Year