95E005002 May 9, 1995
FUEL SYSTEM, OTHER:STORAGE:TANK ASSEMBLY:PRESSURE RELIEF DEVICES
Defect Description
UPON EXPOSURE TO IMPURITIES IN THE NATURAL GAS FUEL IN COLD WEATHER, AN INTERNAL O-RING ON THESE DEVICES CAN BLISTER DURING DECOMPRESSION AFTER "FAST-FILL" REFUELING RESULTING IN SEAL LEAKAGE.
Consequence
INTERNAL DAMAGE TO THE O-RING SEAL COULD CAUSE A RELEASE OF CNG. IF CNG WERE RELEASED TO THE ENVIRONMENT AND AN IGNITION SOURCE WERE PRESENT, A FIRE COULD OCCUR.
Remedy
SCI WILL REPLACE RECALLED UNITS WITH NEW DEVICES THAT ARE NOT SUSCEPTIBLE TO O-RING DAMAGE FROM NON-METHANE COMPONENTS OF THE GAS SUPPLY WHEN THE DEVICES ARE DEVELOPED.