1989 FORD E150

2 recalls — 35 complaints

91V146000 Sep 4, 1991
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
THE DUAL FUEL TANK SELECTOR VALVE MAY MALFUNCTION AND CAUSE AN OVERFILL CONDITION IN ONE OF THE FUEL TANKS, RESULTING IN AN OVERFLOW OF FUEL PAST THE FILLER CAP.
Remedy: REPLACE THE DUAL FUEL TANK SELECTOR VALVE.
350,000 vehicles affected
90V101000 Jun 1, 1990
POWER TRAIN:AUTOMATIC TRANSMISSION:GEAR POSITION INDICATION (PRNDL)
UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.
Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.
111,000 vehicles affected
FUEL SYSTEM, GASOLINE Jul 1, 2008
NHTSA CAMPAIGN ID# 91V146000 REFERS TO A SAFETY RECALL FOR A FAULTY DUAL FUEL TANK SELECTOR VALVE IN FORD ECONOLINE VANS EQUIPPED WITH DUAL FUEL TANKS BUILT BETWEEN 1989 AND 1991 AND OTHER SIMILAR MODELS . I HAVE CONTACTED FORD TO INVESTIGATE , BUT THERE ARE NO RECORDS THAT CONFIRM OR DISAFFIRM MY VEHICLE'S INCLUSION IN THIS RECALL. BASICALLY, I DON'T KNOW IF MY VAN WAS AFFECTED BY THIS RECALL AND IF ANY RECALL SERVICES WERE PERFORMED. I AM EXPERIENCING A FAULT IN THE DUAL FUEL TANK SYSTEM. IT SEEMS THAT THE FUEL SELECTOR VALVE WILL NOT SWITCH TO THE MAIN TANK, AND WHEN FILLED, THE MAIN TANK WILL FLOW PAST THE FILLER CAP AND CAUSES A FUEL LEAKAGE, WHICH CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. I CONTACTED A LOCAL FORD DEALER WHO ADVISED ME THAT NO RECALL SERVICE CAN BE PERFORMED TO REMEDY THIS PROBLEM BECAUSE MY VIN# DOES NOT REGISTER IN THE FORD RECALL DATABASE. AGAIN, FORD CANNOT CONFIRM OR DISAFFIRM ANY RECALL SERVICES PERFORMED ON MY VEHICLE. I AM NOT THE ORIGINAL OWNER OF THIS VEHICLE SO I DO NOT HAVE ANY SERVICE RECORDS PRIOR TO 2005. IN AN ATTEMPT TO CORRECT THIS CONCERN, I HAVE ALREADY REPLACED THE SECONDARY FUEL PUMP, AS ADVISED BY MY LOCAL MECHANIC. I HAVE ALSO OVERHAULED BOTH FUEL TANKS TO CHECK FOR CLOGGING, OR ANY FOREIGN MATERIALS, AND I HAVE REPLACED SEVERAL SEALS AND MISC. HARDWARE IN THE FUEL SYSTEM. THIS CONCERN HAS BEEN A PROBLEM SINCE I PURCHASED THE VEHICLE IN 2005. I AM ONLY ABLE TO OPERATE MY VEHICLE ON THE AUXILLARY (REAR) FUEL TANK WITH A 13 GALLON CAPACITY. WHEN THE SELECTOR SWITCH IS ON THE FRONT TANK, THE VEHICLE WILL EVENTUALLY STALL AS IF IT IS OUT OF FUEL. WHEN THE FUEL SELECTOR SWITCH IS SET TO THE REAR TANK, I AM ABLE TO OPERATE THE VEHICLE NORMALLY WITH THE EXCEPTION OF THE LIMITED RANGE DUE TO THE SMALL AUXILLARY FUEL TANK. *TR
FUEL SYSTEM, GASOLINE Apr 25, 2008
VAN DIED,TOWED TO MECHANICS SHOP,WAS TOLD SWITCH VALVE BETWEEN TANKS WAS PROBLEM, LOOKED ON NHTSA WEBSITE ABOUT RECALLS. FORD VAN 89 E-150 WITH DUEL GAS TANKS. FORD SAFETY RECALL NUMBER IS 91S39 WENT TO FORD WEB SITE,CALLED THEM ON PHONE, CUSTOMER SERVICE AND LOCAL DEALERSHIP. BOTH SAID THERE WAS NO RECALL ON MY VAN. *TR
TIRES:VALVE Jun 19, 2003
WHILE DRIVING, THE TIRE EXPERIENCED TREAD SEPARATION AND DAMAGED THE FRONT FENDER. *AK THE VALVE STEM WAS ALSO REPLACED. *PH *JB
TIRES:TREAD/BELT Jun 19, 2003
WHILE DRIVING, THE TIRE EXPERIENCED TREAD SEPARATION AND DAMAGED THE FRONT FENDER. *AK THE VALVE STEM WAS ALSO REPLACED. *PH *JB
ELECTRICAL SYSTEM:IGNITION Oct 30, 2000
IGNITION MODULE HAS BEEN GIVING US PROBLEMS SINCE PURCHASED-1993- ONE TIME THE MODULE FAILED AND ANOTHER TIME IT WAS REPLACED, STILL THE PROBLEM PERSISTS. *AK
ELECTRICAL SYSTEM:IGNITION Oct 25, 2000
BEGAN HAVING SERIOUS PROBLEM WITH STALLING APPROX. 2 MOS AGO , STALLED WHILE AT HIGHWAY SPEEDS AND WHILE CROSSING INTERSECTIONS , ENDANGERING THE SAFETY OF MY FAMILY , WHICH CONSISTS OF MYSELF ,MY WIFE , AND OUR FOUR SMALL CHILDREN. THIS PROBLEM HAS OCCURED 7 TIMES. I HAVE REPAIRED IT TWICE. RECENTLY I TOOK IT TO THE LOCAL FORD DEALERSHIP. AND AT FIRST THEY DENIED AND PROBLEM AND THE RECENT RECALL IN CALIFORNIA. IHAVE DONE A CONSIDERABLE AMOUNT OF RESEARCH REGARDING THIS PROBLEM INCLUDING MEETING WITH A REGIONAL FORD DISTRICT SERVICE MANAGER. PLEASE , PLEASE HELP ME...
ELECTRICAL SYSTEM:WIRING:INTERIOR/UNDER DASH Sep 5, 2000
THE AIR CONDITIONING BLOWER MOTOR SWITCH WAS MELTED I REPLACED IT AND IT MELTED AFTER 4000 MILES. I WENT TO A SALVAGE YARD AND THEY WERE ALL MELTED IN THE HI POSITION. WHEN ON HI THE WIRING GET SO HOT YOU CANNOT HOLD THE WIRES
ELECTRICAL SYSTEM:ALTERNATOR/GENERATOR/REGULATOR Jun 11, 1999
ALTENATEOR HARNESS PLUG CONNECTOR SUDDENLY SHORT CIRCUTED, AND CAUSED VEHICLE TO CATCHON FIRE. DEALER HAS NOT BEEN CONTACTED. *AK
Fire
ELECTRICAL SYSTEM:WIRING:INTERIOR/UNDER DASH Jun 7, 1999
FIRE STARTED ON DRIVERS SIDE NEAR STEERING WHEEL AND DASHBOARD.NM
Fire 1 injured
STRUCTURE:BODY:BUMPERS Mar 10, 1999
BUMPER ASSEMBLY MISSING PARTS THAT ARE ON ASSEMBLY DRAWING, POSSIBLE CAUSE FOR THE STEP BUMPER OF THE VAN TO BREAK AWAY FROM THE FRAME WHILE TOWING.
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK Feb 17, 1999
VEHICLE HAS AUXILIARY FUEL TANK. WHEN FIRST TANK IS FILLED WITH GAS IT CAUSES SPILLAGE OF SECOND TANK. CAUSE UNKNOWN. *AK
UNKNOWN OR OTHER May 13, 1998
STEP BUMPER ON THE VAN BROKE AWAY FROM THE FRAM WHILE TOWING A TRAVEL TRAILER, DUE TO MISSING PARTS.
ENGINE AND ENGINE COOLING:ENGINE:GASOLINE Feb 20, 1998
ENGINE STALLS.
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK Oct 29, 1997
WHEN ONE FUEL TANK ON A DUAL FUEL TANK ASSEMBLY FILLS UP IT OVERFLOWS, LEAKING GAS. *AK
ENGINE AND ENGINE COOLING:ENGINE:GASOLINE Sep 30, 1997
WHILE DRIVING VEHICLE STALLS AND CUTS OFF COMPLETLY. OWNER HAD TO HAVE VEHICLE TOWED TO DEALER. *AK
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES Mar 4, 1997
THE VEHICLE'S DUAL GAS TANK IS INOPERATIVE, CAUSING FRONT GAS TANK TO OVERFILL/SPILL WHEN REAR IS SWITCHED. *AK
ENGINE AND ENGINE COOLING Jul 25, 1996
CLIMATE CONTROL FAN SWITCH MELTED/BURNED. *SD
Fire
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES Jul 16, 1996
FUEL IS LEAKING FROM THE GAS TANK OF THE VEHICLE. *AK
ELECTRICAL SYSTEM:IGNITION:SWITCH Jun 28, 1996
IGNITION SWITCH SHORT DUE TO LOOSENESS. *DH
ELECTRICAL SYSTEM:ALTERNATOR/GENERATOR/REGULATOR Jun 24, 1996
ALTENATOR HEATED UP THE WIRING HARNESS, RESULTING IN A FIRE. *AK *JB
Fire
ELECTRICAL SYSTEM:IGNITION:SWITCH Jun 24, 1996
IGNITION SHORTED OUT/FAILED. *DH
POWER TRAIN:MANUAL TRANSMISSION Jun 12, 1996
DRIVING VEHICLE AT SPEED 65MPH, UNDER THE HOOD FIRE, SMELL OF WIRING BURNING, ELECTRICAL SHORT. *AK
Fire
ELECTRICAL SYSTEM:IGNITION Jun 12, 1996
DRIVING VEHICLE AT SPEED 65MPH, UNDER THE HOOD FIRE, SMELL OF WIRING BURNING, ELECTRICAL SHORT. *AK
Fire
SEAT BELTS:FRONT:BUCKLE ASSEMBLY May 20, 1996
DURING A PANIC STOP REAR SEAT BELTS LOOSENED, THROWING CHILD STRAPPED IN CAR SEAT ON THE FLOOR. *AK
EQUIPMENT:APPLIANCE:AIR CONDITIONER Apr 17, 1996
MANUFACTURER USES IMPROPER 'O' RING IN AIR CONDITIONER, CAUSING AIR CONDITIONER TO LEAK. *DSH
POWER TRAIN:DRIVELINE Sep 22, 1995
THE FRONT BRAKE STILL MAKES HEAT,THE REAR END AXLE WAS REPLACED . TT
SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:DISC Sep 22, 1995
THE FRONT BRAKE STILL MAKES HEAT,THE REAR END AXLE WAS REPLACED . TT
FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES Jul 28, 1995
HE FUEL TANK SELECTOR VALVE MALFUNCTIONED CAUSING FUEL TO SPILL. SEE RECALL MFG RECALL N0.91S39. NHTSA 91V146. *AK
ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:MANIFOLD/HEADER/MUFFLER/TAIL PIPE Jun 14, 1995
THE MUFFLER RUPTURED ON TOP AND TOWARD THE FUEL LINE. *AK
FUEL SYSTEM, GASOLINE:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS Jun 14, 1995
THE PLASTIC FUEL LINE MELTED OFF THE FUEL TANK, CAUSING FUEL TO LEAK OUT OF THE FUEL TANK. *AK
ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:MANIFOLD/HEADER/MUFFLER/TAIL PIPE Jun 14, 1995
CRACKS DEVELOPED ON EXHAUST MANIFOLD GASKET CAUSED BY OVERHEATING AND POOR DESIGN. TT
SUSPENSION:FRONT May 15, 1995
TOOK ALL THE GREASE FITTING, RESULTING IN CONSTANT ALIGNMENT PROBLEM. TT
ELECTRICAL SYSTEM:WIRING:FRONT UNDERHOOD Feb 24, 1995
ENGINE COMPARTMENT FIRE, VEHICLE PARKED IN DRIVEWAY. TT
Fire
TIRES:TREAD/BELT Feb 13, 1995
ALL FOUR TIRES BLISTERED BETWEEN THE TREADS. TT
STEERING:LINKAGES:TIE ROD ASSEMBLY Jan 18, 1995
STEERING; THE TIE ROD BALL JOINT WEARS OUT. TT