1977 DODGE B200
1 recalls, 3 complaints
80V027000 Mar 14, 1980
STRUCTURE:FRAME AND MEMBERS
Defect Description
THE FRONT RAIL EXTENSION MAY EXPERIENCE FATIGUE CRACKING NEAR THE AREA WHERE THE POWER STEERING GEAR ATTACHES TO THE FRAME. IF THE CRACK PROGRESSES THROUGH MOST OR ALL OF THE RAIL SECTION, STEERING SYSTEM FREE PLAY ACCOMPANIED BY METALLIC RATTLE NOISE WILL BE EXPERIENCED.
Remedy
AFFECTED VEHICLES WILL BE WELD REPAIRED AND A REINFORCEMENT ROD WILL BE INSTALLED OVER THE CRACKED AREA.
Complaint Statistics
3 total complaints
Top Reported Components
| Component | Complaints |
|---|---|
| LATCHES/LOCKS/LINKAGES:DOORS:LATCH | 1 |
| STRUCTURE:FRAME AND MEMBERS | 1 |
| FUEL SYSTEM, OTHER:STORAGE:FUEL GAUGE SYSTEM | 1 |
FUEL SYSTEM, OTHER:STORAGE:FUEL GAUGE SYSTEM
Dec 23, 1998
Incident date: Nov 2, 1998
THE FUEL TANK FLOAT SENDER HAD BROKEN LOOSE, CAUSING FUEL TANK TO LEAK. *AK
STRUCTURE:FRAME AND MEMBERS
Aug 19, 1997
RECALL 80V-027000, DLR REFUSES TO DO THE RECALL FOR FREE. *AK
LATCHES/LOCKS/LINKAGES:DOORS:LATCH
Jul 24, 1997
Incident date: Jun 1, 1997
SLIDING DOOR LATCH BROKE.
DODGE B200 - All Years Overview
Complete safety history for the DODGE B200 across all model years (1971, 1988).
27
Total Recalls
7
Total Complaints
0
Investigations
0
Reported Crashes
0
Reported Fires
0
Reported Deaths
DODGE B200 - Year by Year
Compare recalls and complaints across model years. Click any year to see full details.