| Date | Product | Reason | Class | Firm |
|---|---|---|---|---|
| Nov 29, 2016 | CentraLink¿ Data Management System Software Versions: v13x,v14x,v15x The C... | There is a remote possibility CentraLink may download an order to the ADVIA Automation System wit... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Nov 22, 2016 | SIEMENS IMMULITE 2000/2000 Xpi Systems Intact PTH (Parathyroid Hormone) T... | Siemens is conducting this recall for the IMMULITE¿ 2000/IMMULITE¿ 2000 XPi Intact PTH (Intact Pa... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Nov 18, 2016 | IMMULITE 2000/IMMULITE 2000 XPi Systems Prostate-Specific Antigen (PSA) Assay... | Siemens Healthcare Diagnostics confirmed that the IMMULITE 2000/ IMMULITE 2000 XPi Systems PSA a... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Nov 18, 2016 | IMMULITE/IMMULITE 1000 Systems Prostate-Specific Antigen (PSA) Assay, REF/Cat... | Siemens Healthcare Diagnostics has confirmed that the IMMULITE/ IMMULITE 1000 Systems PSA assays ... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Oct 21, 2016 | ADVIA 560 Hematology Systems, Siemens Material Number (SMN) 11170842, IVD. | Siemens is investigating an issue which may cause an incorrect result to be reported. Siemens rec... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Oct 7, 2016 | Advia Chemistry Calibrator For in vitro diagnostic use in the calibration o... | Siemens has confirmed that the DBIL_2 Assigned Calibrator Values (ACV) currently assigned to the ... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Sep 29, 2016 | FlexLab Automation Modules | Class II | Siemens Healthcare Diagnostics, Inc. | |
| Sep 29, 2016 | Aptio Automation Modules | Possible overheating of power cord plugs used to connect to FlexLab and Aptio Automation systems. | Class II | Siemens Healthcare Diagnostics, Inc. |
| Sep 15, 2016 | Dimension Vista Chemistry 1 Calibrator The Chemistry 1 Calibrator (KC110B) i... | Siemens determined that discrepant low calcium recovery of QC and patient samples can occur with ... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Aug 30, 2016 | IMMULITE 2000/IMMULITE 2000XPi Systems CMM CMV IgM Assay, REF/Catalog Number ... | Multiple customers reported seeing an increase in imprecision with some patients resulting in hig... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Aug 30, 2016 | IMMULITE/ IMMULITE 1000 Systems CMM CMV IgM Assay, REF/Catalog Number LKCM1(D... | Multiple customers reported seeing an increase in imprecision with some patients resulting in hig... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Aug 25, 2016 | Dimension IRON Flex reagent cartridges | Siemens Healthcare Diagnostics has become aware of deferoxamine interference with Dimension and D... | Class III | Siemens Healthcare Diagnostics, Inc. |
| Aug 25, 2016 | Dimension Vista IRON Flex reagent cartridges | Siemens Healthcare Diagnostics has become aware of deferoxamine interference with Dimension and D... | Class III | Siemens Healthcare Diagnostics, Inc. |
| Aug 24, 2016 | SIEMENS IMMULITE/IMMULITE 1000 Systems Rubella IgM (RUM), REF/Catalog Number ... | Siemens received multiple customer complaints indicating an increase in false positive and indete... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Aug 24, 2016 | SIEMENS IMMULITE/IMMULITE 2000 Systems Rubella IgM (RUM), REF/Catalog Number ... | Siemens received multiple customer complaints indicating an increase in false positive and indete... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Aug 3, 2016 | Dimension Vista¿ Calcium (CA) Flex¿ reagent cartridge Device Listing No.: D... | Siemens Healthcare Diagnostics determined that the Dimension Vista Calcium (CA) Flex reagent cart... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Jul 20, 2016 | ADVIA Chemistry XPT, SMN 10723034, IVD. --- This issue affects only the ADVIA... | Siemens identified an issue with the ratio equation provided on the ADVIA Chemistry XPT System So... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Jun 17, 2016 | Syva¿ EMIT¿ 2000 Theophylline - Catalog # 4P019UL /SMN#10445324 is a homogene... | Siemens Healthcare Diagnostics has confirmed the Syva¿ EMIT¿ 2000 Theophylline reagent lot G3, wh... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Jun 17, 2016 | ADVIA¿ Chemistry (Syva Onboard) Theophylline_2 (THEO_2) Reagent is for in vit... | Siemens Healthcare Diagnostics has confirmed the Syva¿ EMIT¿ 2000 Theophylline reagent lot G3, wh... | Class II | Siemens Healthcare Diagnostics, Inc. |
| May 26, 2016 | ADVIA¿ Centaur XPT system software versions V1.0.1 (Bundle 1.0.912 SMN 108197... | Eight (8) issues were identified which may affect the results generated by the system software ve... | Class II | Siemens Healthcare Diagnostics, Inc. |
| May 5, 2016 | The Enzyme 2 Calibrator is an in vitro diagnostic product for the calibration... | Complaints of positive shift of patient and QC results when the ALTI assay is calibrated with the... | Class III | Siemens Healthcare Diagnostics, Inc. |
| May 5, 2016 | The Enzyme II Calibrator is an in vitro diagnostic product for the Alanine Am... | Complaints of positive shift of patient and QC results when the ALTI assay is calibrated with the... | Class III | Siemens Healthcare Diagnostics, Inc. |
| Apr 28, 2016 | ADVIA Centaur XPT Immunoassay System | The ADVIA Centaur¿ XPT default setting for the Daily Maintenance Task (Daily Cleaning Procedure) ... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Apr 15, 2016 | IG1, IGF-I reagent, Catalog # LKGF1; For the quantitative measurement of insu... | 24 minutes of incubation is required prior to processing patient samples and for the pretreatment... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 30, 2016 | ADVIA Centaur CP Immunoassay System, Siemens Material Number (SMN) 10309710,... | The firm identified an issue in sample processing when using EZee-Nest Insert Cups due to two ina... | Class III | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | ADVIA CHEMISTRY ENZYMATIC CREATININE_2 | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Advia Chemistry Assay: LDL Cholesterol, Direct | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Dimension Assays: Uric Acid (URCA) | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Advia Chemistry Assay: Lactate | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Dimension Vista Assays: Enzymatic Creatine (ECRE) | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Advia Chemistry Assays - Cholesterol_2 concentrated and Cholesterol, LDL Chol... | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Advia Chemistry Assay: Uric Acid and Uric Acid, concentrated | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Advia Chemistry Assay: Direct HDL Cholesterol (D-HDL) | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Dimension Vista Assays: Uric Acid (URCA) | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Dimension Vista Assays: Direct HDL Cholesterol (AHDL) | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | ADVIA CHEMISTRY TRIGLYCERIDES_2 (TRIG_2) REAGENT & ADVIA CHEMISTRY TRIGLYCERI... | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Dimension Vista Assays: Triglycerides (TRIG) | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Dimension Assays: Direct HDL Cholesterol (AHDL) | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Dimension Assays: ENZYMATIC CREATININE | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | ADVIA CHEMISTRY GLUCOSE OXIDASE ASSAY AND ADVIA Chemistry Glucose & Concentra... | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 17, 2016 | Dimension Assays: Triglycerides (TGL) | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyron... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 10, 2016 | ADVIA 560 Hematology Systems, Siemens Material Number (SMN) 11170842, IVD ... | Software anomaly; Siemens identified that software version 1.4.2133 on the ADVIA 560 Hematology S... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 8, 2016 | Syva Emit Methotrexate Assay, is a homogeneous enzyme immunoassay intended fo... | Siemens Healthcare Diagnostics confirmed that Syva Emit Methotrexate Application (DVMTX.1) for Di... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Mar 7, 2016 | ADVIA Chemistry Triglyceride_2, concentrated; TRIG_c; Catalog # SMN # 1069757... | Siemens Healthcare Diagnostics has confirmed the ADVIA Chemistry Triglyceride concentrated reagen... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Feb 16, 2016 | Dimension Vista Blood Urea Nitrogen (BUN) Flex reagent cartridge The BUN m... | Siemens Healthcare Diagnostics has determined that Dimension Vista Blood Urea Nitrogen (BUN) lots... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Feb 9, 2016 | Dimension clinical chemistry system, Sirolimus (SIRO) Flex reagent cartridge ... | Siemens Healthcare Diagnostics has received customer complaints regarding QC shifts and imprecisi... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Jan 14, 2016 | BCS Automated Blood Coagulation Analyzer System, Multipurpose system for in v... | False short clotting times for PT on BCS and BCS XP with Dade Innovin can occur. This has also a... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Jan 14, 2016 | BCS XP Automated Blood Coagulation Analyzer System, Multipurpose system for i... | False short clotting times for PT on BCS and BCS XP with Dade Innovin can occur. This has also a... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Nov 19, 2015 | Factor VIII Chromogenic Assay, REF/Catalog No. B4238-40, Siemens Material Num... | Factor VIII Chromogenic Assay Lot 44637 is showing an increased occurrence of irregular curves wh... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Nov 3, 2015 | Dimension Vista System B2 Microglobulin Flex reagent cartridge and urine sta... | Siemens Healthcare Diagnostics has confirmed an increase in the rate of Abnormal Assay errors a... | Class II | Siemens Healthcare Diagnostics, Inc. |