Ew Noland Pond Dam

South Carolina — Spartanburg County — TR-FAWN BRANCH

Location

StateSouth Carolina
CountySpartanburg
RiverTR-FAWN BRANCH
Coordinates35.04990, -82.00000

Physical Characteristics

NID Height20 ft
Dam Height20 ft
Dam Length
NID Storage72 acre-ft
Max Storage72 acre-ft
Surface Area7 acres

Safety Classification

Hazard PotentialHigh
Condition AssessmentFair
EAP StatusYes
Last InspectionJuly 6, 2022
Inspection Frequency2

Dam Information

Year Completed1961
Primary PurposeFire Protection, Stock, Or Small Fish Pond
Dam Type—
Owner TypePrivate
OwnerBRENT W AND NATALIE J WATKINS;REBECCA BROWN JONES
Other NameJones/Noland Dam

Location Map

About This Dam Record

Dam safety data is maintained by the Army Corps of Engineers National Inventory of Dams (NID). High-hazard dams are those where failure could cause loss of life or major property damage downstream.

Back to All Dams More Dams in South Carolina