Consumer Safety Complaints

Search 2,215,138 safety complaints filed by vehicle owners with NHTSA — including 138,663 crashes, 56,255 fires, and 8,561 deaths.

2,215,138 Total Complaints
138,663 Reported Crashes
56,255 Reported Fires
8,561 Reported Deaths

What is a NHTSA consumer complaint?

A consumer complaint is a free-form report filed by a vehicle owner directly to the National Highway Traffic Safety Administration (NHTSA) describing a safety concern about their vehicle. NHTSA collects these reports through its Vehicle Owner Defect Report (VOQ) system and publishes them publicly. Each complaint includes the affected component, the date and circumstances of the incident, whether the failure caused a crash or fire, and any reported injuries or deaths. The owner's full narrative description is included verbatim — NHTSA does not edit or moderate the descriptions.

The database below contains over 2,215,138 individual complaints. NHTSA's investigators monitor it for clusters of similar reports — when enough owners describe the same failure mode on the same vehicle, NHTSA may open a Preliminary Evaluation that can lead to a recall. Many of the largest recalls in U.S. history, including the Takata airbag recall and the Hyundai/Kia engine fire recalls, started as patterns visible in this complaint database years before they became formal recalls.

How to interpret what you read

A few principles for reading consumer complaints usefully:

  • One complaint is anecdote; a hundred similar complaints is data. NHTSA does not investigate the truthfulness of any individual report — that's the job of the Office of Defects Investigation, which looks at the full pattern. When evaluating a vehicle, look for whether multiple owners describe the same chain of events.
  • Crash, fire, injury, and death flags are owner-set. They are not verified by NHTSA. They are still useful as a filter, because owners who tick those boxes are typically reporting more serious incidents than those who don't.
  • Component categories are NHTSA-assigned, not owner-assigned. NHTSA standardizes the component field so that complaints can be aggregated. The owner narrative often goes into more detail than the component category captures.
  • Complaint volume scales with sales volume. A best-selling model will accumulate more raw complaints than a niche model even at the same defect rate. To compare across vehicles, look at complaints per 100,000 units sold, not raw counts.

If you've experienced a defect

File a complaint. NHTSA's investigators rely on this database to detect emerging defects, and useful complaints — specific, concrete, with dates and mileage and clear descriptions of what happened — feed directly into the agency's pattern detection. The form takes about 10 minutes and is at nhtsa.gov/recalls under "Report a Safety Problem." Your complaint becomes part of the same public record that this page is built from. Owners filing detailed VOQs are how recalls get triggered.

Read more from our blog

How to Read NHTSA Consumer Complaints › How NHTSA Investigations Work › Used Car: 7 Recall Checks to Run First › The Takata Airbag Recall: Full Story › OBD-II Codes Explained › All Articles ›
Clear

Showing 1,005 complaints for DUCATI

DUCATI MONSTER S2 R (2005) — FUEL SYSTEM, OTHER Jul 9, 2010
Incident date: Jul 9, 2010
MY 2005 DUCATI MONSTER S2R800 HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS HAVE INCREASED AND IT DOES NOT SIT CORRECTLY IN THE FRAME AND IT NOW ITS GETTING CLOSE TO THE IGNITION SWITCH. ITS THE ORIGINAL TANK , STARTED TO SHOW FEW BUBBLES HERE AND THERE! MIGHT BE WARPING! I WORRY ABOUT MY SAFETY AND AS WELL OF OTHERS. AND HOPE THIS GETS RESOLVE. *TR
DUCATI 1000GT (2008) — FUEL SYSTEM, GASOLINE Jul 6, 2010
Incident date: Jul 3, 2010
THE FUEL TANK HAS EXPANDED AND DEFORMED, ALLOWING IT TO DISENGAGE FROM ITS MOUNTS AND SEPARATE FROM THE MOTORCYCLE. IT ALSO DEVELOPED DIMPLES AND BUMPS ON IT'S OUTER SURFACE. *TR
DUCATI S4 R 2006 (2006) — FUEL SYSTEM, GASOLINE Jul 6, 2010
Incident date: Jan 1, 2008
MY MOTORCYCLE HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME, THE HANDLEBARS HIT IT ON TURNING, AND IT PRESSES AGAINST THE IGNITION SWITCH. PREVIOUSLY IT OPENED AND CLOSED WITHOUT PROBLEMS, NOW I HAVE TO WEDGE IT AGAINST THE IGNITION SWITCH TO CLOSE IT. THE RUBBER MOUNTS NO LONGER SIT ON THE FRA... Read more
DUCATI MONSTER 696 (2007) — FUEL SYSTEM, GASOLINE Jul 6, 2010
Incident date: Jul 3, 2010
MY MOTORCYCLE HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME, THE HANDLEBARS HIT IT ON TURNING, AND IT PRESSES AGAINST THE IGNITION SWITCH. PREVIOUSLY IT OPENED AND CLOSED WITHOUT PROBLEMS, NOW I HAVE TO WEDGE IT AGAINST THE IGNITION SWITCH TO CLOSE IT. THE RUBBER MOUNTS NO LONGER SIT ON THE FRAM... Read more
DUCATI 1000GT (2007) — FUEL SYSTEM, GASOLINE Jul 5, 2010
Incident date: Oct 1, 2009
FUEL TANK EXPANDS OVER TIME AND COMES LOOSE FROM THE MOUNTS. FUEL TANK IS COMPLETELY OFF OF IT'S MOUNTS. THIS IS THE THIRD TANK ON THE MOTORCYCLE. ALL 3 TANKS HAVE HAD THE SAME PROBLEM. *TR
DUCATI 1098 (2008) — FUEL SYSTEM, GASOLINE Jul 1, 2010
Incident date: Jan 7, 2010
STALLED WHILE DRIVING AND WOULD NOT START. DEALER FOUND HIGH PRESSURE FUEL HOSE IN TANK DISCONNECTED, DEALER REPLACED FUEL LINE. *TR
DUCATI 1098 (2008) — ENGINE AND ENGINE COOLING Jul 1, 2010
Incident date: Jun 30, 2010
STALLED WHILE DRIVING AND WOULD NOT START. *TR
DUCATI S4 R 2006 (2006) — FUEL SYSTEM, GASOLINE Jun 29, 2010
Incident date: Apr 22, 2008
2006 DUCATI S2R800 "PLASTIC" FUEL TANK STARTING TO DEFORM. NOT RETAINING ORIGINAL SHAPE. CONCERNS OF POSSIBLE RUPTURE OR LEAKS. GETTING WORSE WITH AGE. UNDER WARRANTY IN 2008, A DUCATI SHOP EXAMINED THE FUEL TANK AND DISMISSED IT AS WARRENTABLE. DATE BELOW IS APPROXIMATE. *TR
DUCATI MONSTER S2 R (2005) — FUEL SYSTEM, GASOLINE Jun 28, 2010
Incident date: May 9, 2010
THE GAS TANK ON MY 2005 DUCATI MONSTER S2R IS EXPANDED AND IS CAUSING PROBLEMS COSMETICALLY, IN ITS FUNCTIONALITY AND WITH MY PERSONAL SAFETY. FIRSTLY THE STEERING STOPS ARE MAXED OUT AND MY HANDLEBAR CONTROLS HIT THE TANK CAUSING A SAFETY ISSUE. THE TANK IS VISIBLY WARPED ALONG BOTH SIDES. THE DUCATI MONSTER S2R TANK SHOULD ONLY HOLD 3 GALLONS WHEN FULL HOWEVER MY TANK CAN CARRY 3.4 GALLONS. TH... Read more
DUCATI MONSTER S4RS (2007) — FUEL SYSTEM, GASOLINE Jun 28, 2010
Incident date: Jun 28, 2010
FUEL TANK ON 2007 DUCATI S4R IS EXPANDING AND BULGING. CONCERNED GAS TANK WILL EVENTUALLY SPLIT, LEAKING FUEL ON HOT ENGINE RESULTING IN FIRE. *TR
DUCATI MONSTER S4RS (2006) — FUEL SYSTEM, GASOLINE Jun 28, 2010
Incident date: Jun 4, 2010
GAS TANK SWELLING AND PUSHING FORWARD ON THE IGNITION SWITCH MAKING IT IMPOSSIBLE TO LATCH THE TANK DOWN SECURE. *TR
DUCATI MONSTER S4 R (2006) — FUEL SYSTEM, GASOLINE Jun 23, 2010
Incident date: Jun 22, 2010
PLASTIC GAS TANK EXPANDING ON DUCATI MONSTER S2R1000. TANK HAS NOT RUPTURED OR FAILED YET, BUT CONTINUED EXPANSION COULD CAUSE DAMAGE. *TR
DUCATI MONSTER S2 R (2005) — FUEL SYSTEM, GASOLINE Jun 22, 2010
Incident date: Mar 1, 2008
THE GAS TANK ON MY 2006 DUCATI S2R HAS BECOME DEFORMED AND IS EXPANDING. NO PARTS HAVE BEEN REPLACED OR REPAIRED. IT STARTED ABOUT ONE OR TWO YEARS AGO<CLOSER TO TWO YEARS. *TR
DUCATI MONSTER 696 (2008) — FUEL SYSTEM, GASOLINE Jun 22, 2010
Incident date: May 28, 2010
FUEL TANK ON MY MOTORCYCLE SWELLING FROM ETHANOL. THE MODEL IS A MONSTER S4RS. *TR
DUCATI 1000GT (2008) — FUEL SYSTEM, GASOLINE Jun 22, 2010
Incident date: Jun 1, 2010
2008 DUCATI SPORT 1000 MOTORCYCLE. THE PLASTIC GAS TANK HAS SPREAD AWAY FROM THE ON THE FRAME. I HAVE SHIMMED IT IN BUT IF IT CONTINUES THERE WILL BE NOTHING TO KEEP THE TANK IN PLACE. DEALER HAS NO FIX. *TR
DUCATI SPORT CLASSIC (2007) — STRUCTURE:BODY Jun 22, 2010
Incident date: May 7, 2010
SPREADING AND BUBBLING ISSUES IN MY GAS TANK. *TR
DUCATI MTS1100S (2009) — FUEL SYSTEM, GASOLINE Jun 21, 2010
Incident date: Sep 1, 2009
THE FUEL TANK ON MY 2009 DUCATI MULTISTRADA 1100S IS EXPANDING/MOVING/WARPING WHICH IS PLACING STRESS ON MY BIKE'S FRAME, LEADING TO THE POTENTIAL FOR CATASTROPHIC STEERING FAILURE AS THE TANK JAMS AGAINST THE HANDLEBARS AND THE HORRIFIC POTENTIAL FOR TANK RUPTURE. *TR
DUCATI MONSTER S2 R (2005) — FUEL SYSTEM, GASOLINE Jun 21, 2010
Incident date: May 11, 2010
THE PLASTIC GAS TANK ON MY MOTORCYCLE IS EXPANDING CAUSING IT TO BE HARD TO LATCH TO THE MOTORCYCLE. *TR
DUCATI S1000BIP (2009) — FUEL SYSTEM, GASOLINE Jun 21, 2010
Incident date: Jun 21, 2010
PLASTIC FUEL TANK ON 2009 DUCATI SPORT 1000 HAS EXPANDED AND IS NOW LOOSE ON THE BIKE, CAUSING A HAZARDOUS SITUATION. TANK HAS BEEN REPLACED ONCE BY DUCATI NORTH AMERICA BUT PROBLEM OCCURRED AGAIN ONLY AFTER A COUPLE OF MONTHS. IT SEEMS THE PLASTIC IS REACTING TO THE GASOLINE OR SOMETHING IN IT (ETHANOL) AND BULGES MAKING IT LOOSE FROM THE FRAME. *TR
DUCATI MONSTER S2 R (2005) — FUEL SYSTEM, GASOLINE Jun 21, 2010
Incident date: May 15, 2010
MY MOTORCYCLE HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME, THE HANDLEBARS HIT IT ON TURNING, AND IT PRESSES AGAINST THE IGNITION SWITCH. PREVIOUSLY IT OPENED AND CLOSED WITHOUT PROBLEMS, NOW I HAVE TO WEDGE IT AGAINST THE IGNITION SWITCH TO CLOSE IT. THE RUBBER MOUNTS NO LONGER SIT ON THE FRA... Read more
DUCATI MONSTER S4 R (2006) — FUEL SYSTEM, GASOLINE Jun 20, 2010
Incident date: Jun 20, 2010
THE PLASTIC GAS TANK ON MY MOTORCYCLE IS SWELLING, CAUSING IT TO NOT FIT PROPERLY ON THE FRAME ANYMORE. IT IS ALSO INTERFERING WITH THE IGNITION SWITCH AND TANK LATCH MECHANISM. THERE IS ALSO COSMETIC DAMAGE (RIPPLES) ON THE SIDE OF THE TANK. AM WORRIED THAT TANK WILL EVENTUALLY FAIL OR LEAK. *TR
DUCATI S2R1000 (2007) — FUEL SYSTEM, GASOLINE Jun 20, 2010
Incident date: Apr 4, 2010
GRADUALLY, OVER TIME, THE MOTORCYCLE'S FUEL TANK STARTED EXPANDING. CURRENTLY THE TANK NO LONGER FITS ON TO THE MOTORCYCLE SECURELY. THE LATCH MECHANISM THAT HOLDS THE TANK CLOSED CAN'T BE SECURED AND THE TANK SLIPS OFF THE FRAME. WHEN RIDING, IT IS POSSIBLE THAT THE TANK WILL SLIDE OFF THE FRAME, CREATING A HAZARDOUS CONDITION. FUEL MIGHT ALSO LEAK OUT OF THE TANK. THE DEALER REPORTS THAT A NEW ... Read more
DUCATI S2R1000 (2007) — FUEL SYSTEM, GASOLINE Jun 20, 2010
Incident date: May 20, 2010
2007 DUCATI S2R 1000 GAS TANK DEFORMING AND NOT FITTING ON THE FRAME PROPERLY. *TR
DUCATI MONSTER 696 (2008) — FUEL SYSTEM, GASOLINE Jun 19, 2010
Incident date: Jun 18, 2010
MY MOTORCYCLE HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME AND IT PRESSES AGAINST THE IGNITION SWITCH. PREVIOUSLY IT OPENED AND CLOSED WITHOUT PROBLEMS, NOW I HAVE TO WEDGE IT AGAINST THE IGNITION SWITCH TO CLOSE IT. THE RUBBER MOUNTS NO LONGER SIT CORRECTLY ON THE FRAME. I HAVE NOT MODIFIE... Read more
DUCATI MONSTER 1000 (2005) — FUEL SYSTEM, GASOLINE Jun 19, 2010
Incident date: Sep 7, 2006
PURCHASED A USED '05 DUCATI MTS 1000S DS FROM THE LOCAL DEALERSHIP. TWO DAYS AFTER GETTING IT HOME I NOTICED THE STRONG SMELL OF GASOLINE IN THE GARAGE. I CALLED DEALERSHIP THEY SUGGESTED THAT WAS NORMAL. A COUPLE OF DAYS LATER I NOTICED STAINING ON THE FRAME RAILS BENEATH THE SEAT AND IT SMELLED OF GASOLINE. I TOOK IT TO DEALERSHIP AND THE TANK WAS CRACKED UNDER THE SEAT AND ACTIVELY LEAKING FUEL... Read more
DUCATI MONSTER S4 R (2006) — FUEL SYSTEM, GASOLINE Jun 19, 2010
Incident date: Mar 1, 2010
THE GAS TANK ON MY 2006 DUCATI MONSTER S2R HAS EXPANDED IN BOTH WIDTH AND LENGTH. THE LARGER DIMENSIONS NOW ALLOW THE HANDLEBARS TO HIT THE TANK WHICH COULD CAUSE A LOSS OF CONTROL/CRASH. ANOTHER WORRISOME ISSUE WITH AN EVER-EXPANDING PLASTIC GAS TANK IS THE FACT THAT IT SITS IN YOUR LAP WHILE RIDING. NOT REALLY WHERE I WOULD WANT A SUDDEN EXPULSION OF FLAMMABLE LIQUID ONTO A HOT ENGINE WHEN THE T... Read more
DUCATI S2R1000 (2007) — FUEL SYSTEM, GASOLINE Jun 18, 2010
Incident date: Feb 11, 2010
THE MOTORCYCLE HAD BEEN IN THE DEALER'S SHOWROOM FOR OVER A YEAR. I BOUGHT THE MOTORCYCLE NEW AND EVERYTHING LOOKED FINE. THE BIKE WAS KEPT CLEAN AND MAINTAINED PROPERLY BY MYSELF AND THE DEALER ACCORDING TO THE SERVICE MANUAL. AFTER A COUPLE MONTHS, I NOTICED THE TANK BUMPERS DID NOT LINE UP WITH THE FRAME CORRECTLY. LATER, I ALSO NOTICED THE TANK WAS PUSHED UP AGAINST THE IGNITION KEY CYLINDER... Read more
DUCATI SPORT CLASSIC (2006) — FUEL SYSTEM, OTHER Jun 18, 2010
Incident date: Mar 10, 2010
PLASTIC TANK ON MY 2006 DUCATI SPORTCLASSIC HAS BEEN REPLACED TWICE BECAUSE OF SPREADING, BUT DUCATI HAS NO FIX. THE TANK GETS SO LOOSE IT CAN COME OFF ITS MOUNTINGS WHICH COULD UNSEAT THE RIDER. *TR
DUCATI SPORT CLASSIC (2006) — STRUCTURE Jun 18, 2010
Incident date: Mar 10, 2010
PLASTIC TANK ON MY 2006 DUCATI SPORTCLASSIC HAS BEEN REPLACED TWICE BECAUSE OF SPREADING, BUT DUCATI HAS NO FIX. THE TANK GETS SO LOOSE IT CAN COME OFF ITS MOUNTINGS WHICH COULD UNSEAT THE RIDER. *TR
DUCATI S4 R 2006 (2006) — FUEL SYSTEM, GASOLINE Jun 18, 2010
Incident date: Jun 1, 2010
EXPANDING AND LEAKING PLASTIC FUEL TANK. PRESENTS FIRE DANGER AND ILL FITMENT IN THE FRAME. *TR
DUCATI MTS 1000 (2004) — FUEL SYSTEM, GASOLINE Jun 18, 2010
Incident date: May 1, 2010
EXPANDING AND LEAKING PLASTIC MOTORCYCLE FUEL TANK. PRESENTS FIRE DANGER AND ILL FITMENT AND ATTACHMENT TO THE FRAME. *TR
DUCATI MONSTER S4RS (2006) — FUEL SYSTEM, GASOLINE Jun 18, 2010
Incident date: Aug 20, 2008
2006 DUCATI MONSTER S2R800 DARK MOTORCYCLE- FUEL TANK WARPED INEXPLICABLY AT THE FUEL PUMP MOUNTING FLANGE, CAUSING A DANGEROUS FUEL LEAK OVER THE HORIZONTAL CYLINDER HEAD. ONLY THE RECOMMENDED FUEL OCTANE LEVEL WAS USED, NO FUEL ADDITIVES USED WHATSOEVER. IT IS MY UNDERSTANDING THAT THIS PARTICULAR WARPING OF THE FUEL TANKS ON THESE DUCATI MODELS IS COMMON, AND INEVITABLE. TO CORRECT THIS FAILURE... Read more
DUCATI MONSTER S4RS (2007) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: May 15, 2010
THE GAS TANK ON MY 2007 DUCATI MONSTER 695 HAS EXPANDED TO THE POINT WHERE IT IS NO LONGER TO PROPERLY ATTACH TO THE MOTORCYCLE. I HAVE REQUESTED A NEW TANK FROM DUCATI NORTH AMERICA, AND AM AWAITING A DECISION ON WHETHER OR NOT TO REPLACE IT. *TR
DUCATI 1000GT (2006) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: Jun 16, 2010
PLASTIC GAS TANK IS EXPANDING. MINOR CRACKING IN CERTAIN AREAS OF TANK. CERTAIN PARTS NO LONGER FIT. TANK NO LONGER ALIGNS WITH FRAME. ACTUAL MOTORCYCLE IS 2006 MULTISTRADA, HOWEVER OTHER MODELS WITH PLASTIC TANKS HAVE SIMILAR PROBLEMS. *TR
DUCATI MONSTER 1000 (2005) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: Jan 1, 2009
THE PLASTIC/COMPOSITE GAS TANK/SEAT COMPONENT IS CHANGING SHAPE (EXPANDING) OVER TIME. THE FIRST SIGN WAS FUEL LEAKING AROUND THE FUEL PUMP SEALS, SLOW AT FIRST, THEN DANGEROUS LEVELS. THE SEAT PAD, WHICH ATTACHES TO THE TANK, CANNOT BE PROPERLY SECURED DUE TO THE SHIFTING OF THE BOLT LOCATIONS. THE TANK/SEAT ITSELF CANNOT BE PROPERLY SECURED INTO THE FRAME NOW, MAKING IT HAZARDOUS TO RIDE. LO... Read more
DUCATI SPORT CLASSIC (2006) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: Jul 1, 2009
EXPANDED FUEL TANK CAUSING INTERFERENCE WITH SAFETY STEERING STOPS. *TR
DUCATI MONSTER S2 R (2005) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: Jan 1, 2007
PLASTIC TANK ON MOTORCYCLE EXPANDS TO THE POINT WHERE IGNITION SWITCH IS PUSHED UP AND TANK DOES NOT SIT PROPERLY ON FRAME. *TR
DUCATI S2R1000 (2007) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: May 10, 2010
THE FUEL TANK HAS SWOLLEN AND BECOME MISSHAPEN. IT NOW RUBS ON THE FRAME IN NUMEROUS PLACES AND DOES NOT PROPERLY SECURE TO THE FRAME OF THE MOTORCYCLE. *TR
DUCATI SPORT CLASSIC (2007) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: Apr 18, 2010
2007 DUCATI SPORT CLASSIC 1000 BIPOSTO. THE GAS TANK ON MY MOTORCYCLE HAS BECOME DEFORMED AND MISSHAPEN. THE DEFORMING OF THE GAS TANK HAS RESULTED IN THE TANK FALLING OFF IT'S MOUNTING POINTS ON THE FRAME AND ALLOWING THE TANK TO DETACH FROM THE MOTORCYCLE IN THE FRONT. IT IS ALSO DISTORTED ENOUGH THAT THE RIGHT HANDLEBAR SWITCH ASSEMBLY ALMOST CONTACTS THE GAS TANK WHEN TURNED TO THE FULL RIG... Read more
DUCATI S2R1000 (2007) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: Jun 17, 2010
VEHICLE IS A 2007 DUCATI S2R1000 MOTORCYCLE. THE GAS TANK IS MADE FROM PLASTIC. THE GAS TANK HAS EXPANDED TO THE POINT THAT THE LATCH IS INOPERABLE WITHOUT JAMMING A SCREWDRIVER UP INTO IT FROM UNDERNEATH. WHEN THE LATCH IS OPERATED EVERY TIME IT REMOVES MATERIAL FROM THE PLASTIC GAS TANK AND THE IGNITION SWITCH HOUSING. ALSO THE EXPANSION OF THE GAS TANK INTERFERES WITH TURNING THE BARS FROM SIDE... Read more
DUCATI MONSTER 696 (2008) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: Jun 1, 2010
THE PLASTIC FUEL TANK ON MY DUCATI MONSTER 695 IS EXPANDING, MAKING IT DIFFICULT TO LATCH AND SECURE PROPERLY. *TR
DUCATI MTS 1000 (2004) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: Jul 1, 2009
I HAVE A 2006 DUCATI MULTISTRADA 1000S DS WITH APPROX. 20,000 MILES. IN 2009, I NOTICED THE PLASTIC FUEL TANK ON MY MOTORCYCLE HAS STRETCHED LENGTHWISE AND BULGED WIDTHWISE TO THE POINT WHERE THE MOUNTING SCREWS DO NOT LINE UP WITH THE TANK. THE FUEL FILLER RECESS IN THE TANK IS ALSO SHOWING CRACKS IN THE PLASTIC. PLASTIC SIDE PANELS ATTACHED TO THE TANK ARE ALSO BEING PUSHED OUT OF PLACE. THE TAN... Read more
DUCATI MONSTER S4RS (2007) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: May 1, 2010
EXPANDING PLASTIC GAS TANK ON A 2007 DUCATI MONSTER S4RS MOTORCYCLE. *TR
DUCATI MONSTER S4RS (2007) — STRUCTURE Jun 17, 2010
Incident date: May 1, 2010
EXPANDING PLASTIC GAS TANK ON A 2007 DUCATI MONSTER S4RS MOTORCYCLE. *TR
DUCATI S4 R 2006 (2006) — FUEL SYSTEM, GASOLINE Jun 17, 2010
Incident date: Jun 17, 2010
THE PLASTIC FUEL TANK ON MY MOTORCYCLE IS DEFORMING. AS A RESULT, IT IS DIFFICULT TO REMOVE THE TANK FROM THE BIKE, AND THE TANK DOES NOT SIT PROPERLY ON THE FRAME. *TR
DUCATI S4 R 2006 (2006) — STRUCTURE:BODY Jun 17, 2010
Incident date: Jun 17, 2010
THE PLASTIC FUEL TANK ON MY MOTORCYCLE IS DEFORMING. AS A RESULT, IT IS DIFFICULT TO REMOVE THE TANK FROM THE BIKE, AND THE TANK DOES NOT SIT PROPERLY ON THE FRAME. *TR
DUCATI S1000BIP (2009) — STRUCTURE:BODY Jun 14, 2010
Incident date: Jun 13, 2010
FUEL TANK BULGING AND SPREADING AT BOTTOM FRONT. THIS EXPANSION HAS CAUSED THE FUEL TANK TO BECOME LOOSE ON THE BRACKET, THE TANK WOBBLES AND CAN BE LIFTED FROM THE FRAME. THIS OCCURRED AFTER ONLY THREE WEEKS OF PURCHASE DATE. I HAVE NOT HAD RESOLUTION YET FROM THE DEALER OR MANUFACTURER. *TR
DUCATI S1000BIP (2009) — FUEL SYSTEM, GASOLINE Jun 14, 2010
Incident date: Jun 13, 2010
FUEL TANK BULGING AND SPREADING AT BOTTOM FRONT. THIS EXPANSION HAS CAUSED THE FUEL TANK TO BECOME LOOSE ON THE BRACKET, THE TANK WOBBLES AND CAN BE LIFTED FROM THE FRAME. THIS OCCURRED AFTER ONLY THREE WEEKS OF PURCHASE DATE. I HAVE NOT HAD RESOLUTION YET FROM THE DEALER OR MANUFACTURER. *TR
DUCATI MONSTER S2 R (2005) — FUEL SYSTEM, GASOLINE Jun 14, 2010
Incident date: Jun 10, 2010
MY MOTORCYCLE HAS A PLASTIC GAS TANK THAT HAS STARTED TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED TO POINT THAT THE ORIGINAL RUBBER GUARDS NO LONGER TOUCH THE FRAME. THE HANDLEBARS HIT THE TANK WHEN ATTEMPTING A FULL TURN TO THE RIGHT - THIS DID NOT HAPPEN BEFORE. COSMETICALLY, I HAVE NOTICED THE APPEARANCE OF PIMPLES ON THE SURFACE OF THE TANK. I HAVE NOT MODIFIED MY MOTORCYCL... Read more
DUCATI 1000GT (2008) — FUEL SYSTEM, GASOLINE Jun 10, 2010
Incident date: Jun 10, 2010
1) THE PLASTIC GAS TANK HAS "SPREAD" OR DEFORMED AND NO LONGER MOUNTS TO FRONT BRACKET OF THE MOTORCYCLE FRAME. IN THE EVENT OF AN ACCIDENT THE TANK WOULD COME LOOSE FROM THE MOTORCYCLE. 2) THE SPREADING SEEMS TO BE CAUSED BY FUEL CONTAINING ETHANOL AND ONCE THE TANK HAS SPREAD IT DOES NOT RETURN TO THE ORIGINAL SHAPE. *TR
Previous 1 2 3 4 5 ... 13 14 15 ... 20 21 Next