Showing 1,005 complaints for DUCATI
Incident date: Jul 12, 2011
FUEL TANK IS SPREADING AND IS NOW LOOSE ON IT'S MOUNTS. POSSIBLE FOR IT TO LIFT AT THE FRONT OF THE TANK. THIS IS UNSAFE AS IT COULD COME LOOSE WHILE DRIVING/RIDING AND CAUSE A SERIOUS ACCIDENT OR LOSS OF CONTROL. ALSO POSES A RISK OF HAVING FUEL LEAKING EITHER WHILE RIDING OR PARKED WHICH I COULD BE FINED FOR. THIS IS A DEFECT THAT IS JUST BEING PATCHED UP AND NOT RECTIFIED BY DUCATI. NUMEROUS
... ATTEMPTS HAVE BEEN MADE TO HAVE THIS PROBLEM SOLVED BY MYSELF AND OTHERS WITH THE SAME PROBLEM. LEAKING FUEL IS ALSO A SERIOUS ENVIRONMENTAL ISSUE AS WELL. *TRRead more
Incident date: Aug 23, 2011
FUEL TANK (PLASTIC) HAS SWOLLEN OND NO LONGER ATTACHES TO THE FRAME OF THE MOTORCYCLE ON THE SIDES. TANK MAY COME OFF IN AN ACCIDENT OR PERHAPS RIDING. THIS COULD BE VERY SERIOUS WITH FIRE, INJURY, LOSS OF CONTROL. *TT
Incident date: Aug 14, 2011
ENGINE CUTS OUT ( STALLS ) ON HIGHWAY IN 6TH GEAR, WHEN CLUTCH IS PULLED IN AND THROTTLE IS CLOSED. THIS PROBLEM HAPPENS INTERMITTANTLY AND WITHOUT WARNING. *TT PLEASE SEE THIS LINK, THERE ARE MANY OTHERS HAVING THE SAME PROBLEM. HTTP://WWW.DIAVEL-FORUM.COM/INDEX.PHP?/TOPIC/377-DIAVEL-STALLING/
Incident date: Jul 1, 2011
THE TANK ON MY 2007 DUCATI SPORT 1000 BIPOSTO HAS SPREAD HALF AN INCH ON EACH SIDE OF THE TANK. THE RUBBER PART OF THE MOUNT HAS EXTENDED ALMOST PASSED THE METAL BRACKET, MAKING IT LOOSE AND EXTREMELY UNSAFE. *TT
Incident date: Jun 18, 2010
1. I NOTICED DIMPLES ON THE TOP OF MY GAS TANK AND THEN CHECKED THE MOUNTING BRACKETS FOR THE GAS TANK. THE GAS TANK COULD BE PULLED COMPLETELY OFF THE MOTORCYCLE WITHOUT MUCH EFFORT. 2. THIS IS A FAILURE THAT CANNOT RECTIFY ITSELF AND SLOWLY DEGRADES MORE AND MORE. 3. THE MOTORCYCLE WAS TAKEN INTO A DUCATI SERVICE SHOP AND THEY "SHIMMED" THE GAS TANK BRACKET TO PREVENT IT FROM BEING ABLE TO REM
... OVE IT COMPLETELY. THE TANK WAS STILL LOOSE, BUT COULD NOT BE REMOVED COMPLETELY. SINCE THE SHIMMING OF THE BRACKETS, THE TANK HAS WARPED AND SPREAD FURTHER AND IS LOOSER THAN WHEN ORIGINALLY SHIMMED. THIS CAUSES A SHAKING OF THE GAS TANK AT NORMAL OPERATING SPEED WHEN MY LEG COMES IN CONTACT WITH THE GAS TANK. *TTRead more
Incident date: Feb 1, 2011
FUEL TANK IS SPREADING AND IS NOW LOOSE ON IT'S MOUNTS. POSSIBLE FOR IT TO LIFT AT THE FRONT OF THE TANK. *TR
Incident date: Aug 18, 2011
FUEL TANK EXPANSION WELL BEYOND SPEC TOLERANCE, IMPACTING STEERING DAMPENER MOUNT AND FURTHER PRESSING AGAINST THE FRONT SUSPENSION. BIKE WAS MAINTAINED BY ORIGINAL OWNER AND ALWAYS REFILLED FROM REPUTABLE GAS STATIONS AND ONLY USED 92 OR 93 OCTANE PREMIUM FUEL. *TR
Incident date: Jul 1, 2010
THE COMPOSITE GAS TANK HAS EXPANDED DUE TO AN INTERACTION WITH THE FUEL. THE FUEL TANK SWELLS AND BULGES FROM THE FRAME OF THE BIKE. THE MALFORMATION OF THE TANK CAUSES THE STEERING AND SUSPENSION TO CONTACT THE TANK WHILE RIDING AND TURNING. THE CONTACT IS CAUSING DAMAGE TO THE FINISH AND CRACKS IN THE TANK. THE OPENING FOR THE KEY IN THE TANK IS OBSTRUCTED AND COULD PREVENT THE LOCKING MECHANISM
... FROM WORKING AND TURNING OFF THE ENGINE. THE MANUFACTURER IS REPLACING TANKS WITH THE SAME PROBLEMATIC TANK IF THE VEHICLE IS UNDER FACTORY WARRANTY AND THE REPAIR IS APPROVED. THIS IS A LENGTHY PROCESS THAT LEAVES THE CUSTOMER WITHOUT USE OF THE MOTORCYCLE WHILE THE DECISION TO REPAIR IS MADE. THE EFFECT OF THE FUEL ON THE TANK IS A KNOWN CONSEQUENCE TO THE MANUFACTURER.Read more
Incident date: Aug 16, 2011
2007 DUCATI MONSTER S4RS PLASTIC TANK IS SWELLING. WAS REPLACED UNDER WARRANTY ONCE. NEW WARRANTED TANK HAS NOW SWELLED. DUCATI HAS THUS FAR, SAID IT IS ONLY A COSMETIC ISSUE. HOWEVER THERE ARE THE CHANCES OF THE TANK SPLITTING, SWELLING TO THE POINT THAT IT WILL NOT LATCH DOWN OR SWELL TO THE POINT THAT IT PUSHES THE SEAT AND POSSIBLY UNLATCHING IT. *KB
Incident date: Aug 3, 2011
RADIATOR LEAK CAUSED BY WEAKENED MOUNTING BRACKET. THIS DESIGN FLAW IS DUE TO EXTRA WEIGHT PLACED ON THE LEFT SIDE MOUNTING BRACKET FROM THE BATTERY MOUNTED ON THE SAME BRACKET. THIS IS A POTENTIAL SAFETY HAZARD AS IT CAUSED EXTREMELY HOT COOLANT TO SPRAY OUT OF THE LEFT FAIRING ON TO THE RIDER'S LEG, IN ADDITION TO CAUSING A CRASH DUE TO LUBRICATED FLUID BEING EXPELLED UNDER THE BIKE WHICH COMP
... ROMISED THE INTEGRITY OF THE CONTACT BETWEEN THE REAR TIRE AND THE ROAD. THIS ITEM NEEDS A RECALL BEFORE SOMEONE LOSES THEIR LIFE! *TRRead more
Crash
Incident date: Jul 25, 2011
TL* THE CONTACT OWNS A 2009 DUCATI 848 MOTORCYCLE. THE CONTACT STATED THAT WHEN DRIVING 50 MPH AND ABOVE, THE FUEL TANK WOULD SHAKE ABNORMALLY. THE VEHICLE WAS INSPECTED BY A DEALER AND THEY ADVISED THAT THE TANK NEEDED TO BE REPLACED DUE TO THE PLASTIC MATERIAL USED DURING MANUFACTURING. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS APPROXIMATELY 4,200. THE VIN WAS UNAVAILABLE.
Incident date: Aug 11, 2011
MY 2008 DUCATI 848 (WHICH ONLY HAS 4100 MILES ON IT) DEVELOPED A RADIATOR LEAK ON THE REAR-LEFT UPPER SIDE OF THE RADIATOR. THERE WERE NO EVENTS LEADING UP THE LEAK. MY BIKE HAS BEEN SITTING FOR TWO WEEKS AND WAS NOT TOUCHED BY ANYONE. DUE TO THE NATURE OF THIS ISSUE, RIDERS MAY BE IN DANGER AS RADIATOR FLUID MAY LEAK ONTO THE FRONT TIRE AND/OR FRONT BRAKES. *TR
Incident date: Feb 15, 2011
THE GAS TANK STARTED TO DEFORM THEN IT STARTED TO SEEP GAS
Incident date: Feb 15, 2011
THE GAS TANK STARTED TO DEFORM THEN IT STARTED TO SEEP GAS
Incident date: Aug 2, 2011
THE FUEL TANK ON MY 2008 DUCATI MODEL MONSTER S4RS TRICOLORE HAS EXPANDED DUE TO A COMMONLY KNOWN PROBLEM OF ETHANOL FUELS REACTING TO THE MATERIAL WHICH THE TANKS ARE MADE FROM. THE TANK HAS SIGNIFICANTLY EXPANDED TO THE POINT WHERE IT NOW IMPEDES THE TURNING OF THE HANDLEBARS AND IS WAVY ALONG THE SIDES WHERE THE KNEES ARE POSITIONED. THE TANK, AS OF YET, DOESN'T APPEAR TO BE LEAKING BUT MANY
... HAVE HAD LEAKS DEVELOP AND IT CERTAINLY APPEARS TO BE A POTENTIAL SAFETY ISSUE. *KBRead more
Incident date: May 12, 2011
TL* THE CONTACT OWNS A 2011 DUCATI DIAVEL. THE CONTACT STATED THE BOLTS THAT HOLD THE REAR TAIL LIGHT ASSEMBLY IN PLACE CAME LOOSE. THE CONTACT TOOK THE VEHICLE TO THE DEALER AND A REPLACEMENT ASSEMBLY WAS ORDERED. THE DEALER DID NOT SAY WHAT MAY HAVE CAUSED THE BOLTS TO FAIL. THE CONTACT WAS CONCERNED ABOUT THE SAFETY RISK BECAUSE THE LIGHT ASSEMBLY RESTED ON THE TAIL PIPE AND MELTED. THE FAILU
... RE AND CURRENT MILEAGE WAS 400. LIGHTS ASSEMBLY HELD TO BIKE BY WIRES ONLY. UPDATED 09/29/2011 *LN *TRRead more
Incident date: Jul 14, 2011
THE GAS TANK HAS EXPANDED APPARENTLY DUE TO AN INTERACTION WITH THE ETHANOL IN THE FUEL. THIS CAUSES IT TO BULGE FROM THE FRAME OF THE BIKE. THE MALFORMATION OF THE TANK CAUSES THE HANDLE BARS TO TOUCH THE TANK LIMITING MOVEMENT, THE OPENING FOR THE KEY TO BE OBSTRUCTED, AND THE PAINT AND DECALS TO BECOME DAMAGED. THE EFFECT OF THE FUEL ON THE TANK IS A KNOWN CONSEQUENCE TO THE MANUFACTURER.
Incident date: Jul 1, 2011
2010 DUCATI STREETFIGHTER FUEL TANK FAILURE, EXPANSION AND BIKE STOPPED RUNNING WHILE ON HIGHWAY. ALMOST GOT REARENDED WHEN POWER WAS LOST. DEALER SAID ETHANOL GAS CAUSED THE PLASTIC FUEL TANK TO DEGRADE, EXPAND AND FAIL. HANDLE BARS NOW HIT THE TANK ALSO. *TR
Incident date: Jul 1, 2011
TL* THE CONTACT OWNS A 2007 DUCATI SPORT CLASSIC 1000 MOTORCYCLE. WHILE DRIVING 25 MPH, THE VEHICLE STALLED WITHOUT WARNING. ALSO, THE FUEL TANK WAS ABNORMALLY STRETCHED DUE TO FUEL LINE TENSION. THE DEALER ADVISED THE CONTACT THAT THE VEHICLE WAS NOT INCLUDED IN NHTSA CAMPAIGN ID NUMBER: 07V017000 (FUEL SYSTEM, GASOLINE: DELIVERY: HOSES, LINES/PIPING, AND FITTINGS). THE MANUFACTURER WAS MADE
... AWARE OF THE FAILURE BUT DID NOT OFFER ANY ASSISTANCE. THE VEHICLE WAS TAKEN TO A PRIVATE MECHANIC WHO REFERRED THE CONTACT TO AN AUTHORIZED DEALER FOR SERVICE. NO REPAIRS WERE PERFORMED. THE CURRENT AND FAILURE MILEAGES WERE 3,600.Read more
Incident date: Apr 21, 2011
ONE DAY RIDING HOME FROM WORK I STARTED TO FEEL LIKE MY KNEE WAS BURNING. I LOOKED DOWN TO MY LEFT KNEE AND SAW THAT IT WAS GETTING WET AND WAS BURNING FROM SOMETHING HOT. PULLED OVER AND SAW THAT I WAS LEAKING COOLANT. THE COOLANT LOOKED LIKE IT WAS COMING OUT OF THE COOLANT HOSE. I HAD THE MOTORCYCLE TOWED TO THE DEALER SHIP THAT I WORK AT. I REMOVED THE FAIRING TO CHECK WHERE IT WAS LEAKING FRO
... M. SAW THAT IT WAS LEAKING OUT OF THE RADIATOR. TRIED TO GET SOME HELP FROM THE LOCAL DEALER AND THEY JUST KEPT TRYING TO SAY THAT IT WAS MY FAULT. THE FIRST THING THEY TOLD ME IS THAT IT WAS A STONE THAT HIT THE RADIATOR. WHEN THEY TOLD ME ABOUT THE STONE I WANTED THEM TO SHOW ME WHERE THE STONE HIT BUT THEY COULDN'T SHOW IT TO ME AND BEFORE TAKING THE BIKE DOWN TO THE DEALER I HAD THE RADIATOR PRESSURE TESTED AND FOUND OUT THAT IT WAS LEAKING FROM THE LEFT UPPER HANGER SPOT WELD. AFTER THEY COULDN'T SHOW ME I TOLD THEM THAT I HAD IT PRESSURE TESTED AND IT SEEMED TO MAKE THEM MAD AND THEN THEY STARTED TO SAY THAT I DROPPED THE BIKE AND I ASKED THEM THE SAME THING AS BEFORE AND THEY COULDN'T SHOW ME WHERE IT HAD SIGNS THAT IT HAD FALLEN. THEN THEY SEEMED TO GET EVEN MORE MAD. I CALLED DUCATI OF NORTH AMERICA AND TOLD THEM WHAT HAD HAPPEN AND THEY TOLD ME THAT THEY WERE SORRY FOR WHAT HAPPENED AND THAT THEY WOULD HELP ME OUT BUT THAT I HAD TO TAKE IT BACK TO THAT DEALER SO THEY COULD CHECK IT OUT AGAIN. BUT I WASN'T GOING TO HAVE IT TOWED DOWN THERE AGAIN AT THAT POINT I COULD'VE BOUGHT A NEW RADIATOR. WHEN THIS HAPPENED IN MARCH I LOOKED UP THE PRICE FOR A NEW ONE AND IT WAS $548 AND NOW ITS GONE UP TO $948 AND THE PART NUMBER HAS CHANGED TO 54840742B FROM 54840741B. EVEN WHEN I TALKED TO THE PERSON AT DUCATI HE TOLD ME THAT THEY KNEW THAT THERE WAS A PROBLEM WITH THE RADIATORS THAT ARE IN THE 1098 AND THE 848. AND AS FOR MY KNEE I HAD TO BUY A BURN CREAM SO IT WOULDN'T HURT FROM THE BURN AND THE GLYCOL IN THE COOLANT. *TRRead more
1 injured
Incident date: Apr 21, 2011
TL* THE CONTACT OWNS A 2009 DUCATI 848 MOTORCYCLE. THE CONTACT STATED THAT THE TEMPERATURE GAUGE DISPLAYED A READING OF 205 DEGREES AS HE NOTICED COOLANT FLUID LEAKING FROM THE RADIATOR. THE VEHICLE WAS TAKEN TO A PRIVATE MECHANIC WHO INSPECTED THE VEHICLE AND INFORMED THE CONTACT THAT COOLANT FLUID WAS LEAKING FROM A SPOT WELD ON THE LEFT SIDE HANGER. THE DEALER HAD NOT BEEN NOTIFIED OF THE FAIL
... URE SINCE THE VEHICLE WAS NO LONGER UNDER WARRANTY AND THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILURE. THE VEHICLE WAS NOT REPAIRED. THE CURRENT AND FAILURE MILEAGE WAS 22,500. THE VIN WAS UNAVAILABLE.Read more
Incident date: Jun 16, 2010
I HAVE A WARPED/EXPANDING GAS TANK ON A 2007 DUCATI MONSTER 695 MOTORCYCLE. *TR
Incident date: May 13, 2011
TL* THE CONTACT OWNS A 2006 DUCATI MTS 620 MOTORCYCLE. THE CONTACT STATED THAT THE FUEL TANK WAS EXPANDING TO THE POINT WHERE THE TANK WAS OVERLAPPING OTHER COMPONENTS OF THE ENGINE. THE CONTACT BELIEVED THE FAILURE TO BE CAUSED BY ETHANOL IN THE FUEL THAT WAS CAUSING THE PLASTIC FUEL TANK TO EXPAND. IN ADDITION, THE CONTACT STATED THAT THE SEAT WAS INCORRECTLY SIZED. THE MOTORCYCLE WAS NOT REP
... AIRED. THE FAILURE MILEAGE WAS 4,500.Read more
Incident date: May 13, 2011
TL* THE CONTACT OWNS A 2006 DUCATI MTS 620 MOTORCYCLE. THE CONTACT STATED THAT THE FUEL TANK WAS EXPANDING TO THE POINT WHERE THE TANK WAS OVERLAPPING OTHER COMPONENTS OF THE ENGINE. THE CONTACT BELIEVED THE FAILURE TO BE CAUSED BY ETHANOL IN THE FUEL THAT WAS CAUSING THE PLASTIC FUEL TANK TO EXPAND. IN ADDITION, THE CONTACT STATED THAT THE SEAT WAS INCORRECTLY SIZED. THE MOTORCYCLE WAS NOT REP
... AIRED. THE FAILURE MILEAGE WAS 4,500.Read more
Incident date: Dec 1, 2010
THE REAR BRAKE REPEATEDLY FAILS PRESUMABLY DUE TO AIR IN THE SYSTEM. I HAVE HAD THE BRAKE BLED 6 TIMES NOW SINCE SEPTEMBER 2010 (4 TIMES BY THE SERVICE DEALER). ONCE THE BRAKE IS BLED IT FAILS AGAIN AFTER APPROXIMATELY 200 MILES. I BELIEVE THIS TO BE A DANGEROUS SITUATION AND NETHER THE DEALER NOR THE MANUFACTURER HAVE PROVIDED ME A SOLUTION. *TR
Incident date: May 17, 2011
TL* THE CONTACT OWNS A 2008 DUCATI 848 MOTORCYCLE. THE CONTACT STATED THAT THE RADIATOR WAS LEAKING ABNORMALLY FROM THE REAR. THERE WAS NO ROAD HAZARD THAT CAUSED THE RADIATOR TO FAIL. THE CONTACT STATED THAT THE VEHICLE WOULD BE TAKEN TO THE DEALER WITHIN THE NEXT TWO DAYS FOR INSPECTION AND POSSIBLE REPAIRS. THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILURE. THE VIN WAS UNAVAILABLE. THE FAILUR
... E MILEAGE WAS 3,600.Read more
Incident date: Mar 15, 2011
COMPLETE FAILURE OF REAR BRAKE.
Incident date: Apr 1, 2011
I OWN A 2005 DUCATI S2R 800 MOTORCYCLE. MY FUEL TANK HAS EXPANDED BEYOND THE POINT WHERE THE PAINT HAS STARTED TO CRACK AND IT HAS BECOME DIFFICULT TO OPEN THE LATCH TO GET ACCESS TO THE BATTERY AND OTHER COMPONENTS. I HAVE ALREADY HEARD THAT THIS IS NOT AN UNCOMMON ISSUE WITH CERTAIN DUCATI FUEL TANKS. DUCATI HAS REFUSED TO COVER THE TANK DAMAGE AND AFTER SPEAKING WITH THE MECHANIC, HE TOLD ME
... THAT THE TANK WILL CONTINUE TO EXPAND AND POSSIBLY LEAK MORE GASOLINE AS TIME GOES ON. I DON'T WANT TO IMAGINE WHAT COULD POSSIBLY HAPPEN AS THE TANK CONTINUES TO EXPAND AND GASOLINE CONTINUES TO LEAK. *TRRead more
Incident date: Mar 20, 2011
FUEL TANK EXPANSION LOOSENS TANK WHERE IT CAN COME OFF EASILY. THIS TANK WAS ALREADY REPLACED 1 1/2 YRS AGO & WHILE I JUST NOTICED IT, I WASN'T AWARE OF WHAT TO LOOK FOR UNTIL VISITING DEALER & OTHER CUSTOMER INSPECTED MY TANK TO COMPARE TO HIS. APPARENTLY MINE HAD BEEN SPREADING FOR SOME TIME PRIOR. DEALER HAS SAID DUCATI HAD BRACKET & WILL INSTALL AT NO CHARGE. MY CONCERN IS TANK INTEGRITY FROM
... SPREADING. *TRRead more
Incident date: Apr 1, 2011
REAR BRAKE REPEATEDLY INOPERABLE. *TR
Incident date: Jul 8, 2010
GAS TANK HAS SPREAD AND IS NO LONGER SECURELY MOUNTED TO THE MOTORCYCLE. *TR
Incident date: Apr 10, 2011
TL*THE CONTACT OWNS A 2009 DUCATI MONSTER 696. THE CONTACT STATED THAT WHILE DRIVING INTO HIS GARAGE HE NOTICED FUEL LEAKING OUT OF THE VEHICLE AND LEAKING ON HIM. THE VEHICLE WAS THEN TOWED TO A DEALER WHO WAS UNABLE TO DIAGNOSE THE FAILURE OR REENACT IT. THE MANUFACTURER WAS NOT CONTACTED. THE FAILURE AND CURRENT MILEAGES WERE APPROXIMATELY 2,100.
Incident date: Apr 7, 2011
THE FUEL TANK ON MY DUCATI S2R800 HAS WARPED DUE TO THE ETHANOL IN GAS. GAS LEAKED FROM THE TANK BECAUSE THE FUEL PUMP GASKET COULD NOT PROPERLY FUNCTION DUE TO THE WARPING. DUCATI'S POOR MANUFACTURING OF THESE GAS TANKS HAS CAUSED THIS PROBLEM. *TR
Incident date: Apr 15, 2011
EXPANDING GAS TANK IN 2005 DUCATI MONSTER POSES RISK OF LEAKING FUEL FROM WARPED FUEL PUMP O-RING GASKET. *TR
Incident date: Oct 9, 2009
I PURCHASED A 2006 DUCATI SPORTCLASSIC FROM A DUCATI DEALER IN 2006, AND HAVE SINCE PUT APPROXIMATELY 2700 MILES ON THE BIKE. THE MOTORCYCLE HAS ALWAYS BEEN GARAGED AND PREMIUM FUEL USED. THE MOTORCYCLE'S GAS TANK IS MADE OF SOME SORT OF PLASTIC OR FIBERGLASS, AND SO IT HAS SPREAD TO THE POINT WHERE THE RUBBER CUPS THAT ARE SUPPOSED TO HOLD IT TO THE FRAME ON EITHER SIDE ARE NO LONGER IN PLACE
... . SINCE THE TANK IS ONLY HELD ONTO THE FRAME VIA ONE SCREW MOUNT, THE TANK CAN BE ALMOST COMPLETELY LIFTED OFF OF THE FRAME IN THE FRONT. THE TANK HAS ALSO WARPED ON THE TOP RIGHT SIDE, IN A "WAVY" PATTERN. DUE TO THE LOOSENESS OF THE TANK, IF THIS BIKE WERE TO BE IN AN ACCIDENT, THE TANK COULD COME OFF AND RESULT IN A FIRE, POSSIBLY BECOME A BOMB. IN ADDITION TO THE LOOSE TANK, SINCE IT HAS SPREAD ON THE BOTTOM, THE HANDLE BAR ON THE LEFT HAND SIDE NOW COMES INTO CONTACT WITH THE TANK, WHICH COULD CAUSE AN AESTHETIC BLEMISH, AND REDUCES THE TURNING RADIUS, IN ADDITION TO POSSIBLY CAUSING INJURY AT SLOW SPEEDS IF THE RIDER CATCHES HER HAND BETWEEN THE BAR AND TANK. I HAVE CONTACTED A DEALERSHIP NEARBY, AND THEY WILL TAKE PICTURES OF IT, AND HAVE TOLD ME THAT DUCATI WANTS THE DEALERSHIP TO "SHIM" THE TANK FIRST, MEANING THAT THEY WOULD ADD WASHERS ON EITHER SIDE TO TRY TO STABILIZE THE TANK. IF THIS IS UNABLE TO BE FIXED, DUCATI *MAY* REPLACE THE TANK WITH A TANK OF THE SAME TYPE OF MATERIAL, AND THE PROBLEM WOULD HAPPEN AGAIN. IF THE BIKE, WHICH IS A 2006, IS OUT OF WARRANTY, DUCATI MAY MAKE ME PAY FOR THE "REPLACEMENT" TANK (APPROX $1800), AND HAS (TO DATE) OFFERED NO REAL SOLUTION TO THE ISSUE (I.E. A TANK MADE OF DIFFERENT MATERIAL). *TRRead more
Incident date: Apr 8, 2011
FUEL SYSTEM, GASOLINE:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS. BIKE WILL STOP RUNNING AT ANY TIME, SOMETIMES WILL NOT START. SAME AS 2007 RECALL. *TR
Incident date: Apr 8, 2011
FUEL SYSTEM, GASOLINE:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS. BIKE WILL STOP RUNNING AT ANY TIME, SOMETIMES WILL NOT START. SAME AS 2007 RECALL. *TR
Incident date: Apr 4, 2011
TL* THE CONTACT OWNS A 2007 DUCATI MONSTER S4RS MOTORCYCLE. THE CONTACT STATED THAT THE FUEL TANK WAS SWELLING AND CAUSING A FUEL LEAK ON TO THE MOTOR IN WHICH THE CONTACT WAS CONCERNED COULD POTENTIALLY CAUSE A FIRE. THE CONTACT CALLED THE DEALER REGARDING THE SWELLING FUEL TANK BUT THE DEALER DID NOT PROVIDE THE CONTACT WITH ANY INFORMATION. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS
... 7,800.Read more
Incident date: Mar 1, 2011
IT APPEARS AS THOUGH THE POLYCARBONATE FUEL TANK ON THE MOTORCYCLE HAS SAGGED OR SPREAD, MAKING THE FRONT OF THE TANK LOOSE. WHEN THE TANK SPREAD, THE FRONT GROMMETS NO LONGER MAKE CONTACT WITH THE TANK, MAKING IT LOOSE. THIS POSES A SERIOUS SAFETY HAZARD. THIS FAILURE DID NOT HAPPEN ALL AT ONCE, BUT OVER TIME. *TR
Incident date: Dec 1, 2010
2006 DUCATI MONSTER S2R GAS TANK IS EXPANDING AND FLEXING. EVENTUAL FAILURE WOULD LEAD TO FUEL LEAKING ONTO HOT ENGINE AND EXHAUST PARTS. *TR
Incident date: Sep 13, 2007
FIRST INCIDENT OF TANK SPREADING AND COMING LOOSE FROM RETAINER 9/07 AND WAS SHIMMIED TO MAKE FUEL TANK SECURE. SECOND INCIDENT OF FUEL TANK SPREADING 6/08 AND WAS SHIMMIED AGAIN. THIRD TIME 8/09 AND FUEL TANK WAS REPLACED WITH NEW PART. NEW FUEL TANK IS NOW (3/11) EXHIBITING SAME SPREADING AND COMING LOOSE FROM FRONT RETAINER.
Incident date: Mar 5, 2011
TL* THE CONTACT OWNS A 2008 DUCATI 1098 MOTORCYCLE. THE CONTACT STATED THAT THE FUEL TANK SWELLED TO MORE THAN THREE QUARTERS ITS NORMAL SIZE. THIS FAILURE CAUSED FUEL TO LEAK OUT OF THE FUEL TANK. THE CONTACT BELIEVED THE FAILURE WAS CAUSED BY THE ETHANOL USED IN GASOLINE. THE VEHICLE WAS TAKEN TO THE DEALER AND THE CONTACT WAS INFORMED THAT BECAUSE THEY WERE AWARE OF THE FAILURE, THE VEHICLE WO
... ULD BE REPAIRED BUT THE FUEL TANK WOULD BE REPLACED WITH THE SAME TYPE OF FUEL TANK THAT PREVIOUSLY FAILED. THE FAILURE AND CURRENT MILEAGE WAS 7,000.Read more
Incident date: Feb 5, 2011
I BOUGHT A 06 MONSTER 620 DARK BACK IN FEB 06. THE DEALER I BOUGHT IT FROM IS CLOSED. HAD THE BIKE SERVICED ONLY BY THE ORIGINAL DEALER WHEN IT WAS SERVICED. THE BIKE HAS 3600 MILES ON SO I GO TO WORK ON IT TO JUST CLEAN IT UP AND CHANGE THE OIL AND I CAN'T GET THE TANK TO LATCH. SO I GO ON LINE TO LOOK FOR A FIX AND START FINDING THE ISSUES ABOUT THE TANK EXPANSION. *TR
Incident date: Feb 22, 2011
MY MOTORCYCLE HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME, THE HANDLEBARS HIT IT ON TURNING, AND IT PRESSES AGAINST THE IGNITION SWITCH. PREVIOUSLY IT OPENED AND CLOSED WITHOUT PROBLEMS, NOW I HAVE TO WEDGE IT AGAINST THE IGNITION SWITCH TO CLOSE IT. THE RUBBER MOUNTS NO LONGER SIT ON THE FRA
... ME. I HAVE NOT SIGNIFICANTLY MODIFIED MY MOTORCYCLE EXCEPT FOR AN AFTERMARKET EXHAUST AND SOME COSMETIC CHANGES. I HAVE MADE NO MODIFICATIONS TO THE FUEL TANK OR FUEL PUMP. I TOOK THE BIKE TO THE DEALER (HATTAR MOTORSPORTS) WHO SUBMITTED A CLAIM TO DUCATI NORTH AMERICA (THE IMPORTER/FACTORY). I HAVE BEEN TOLD IT WILL BE REPLACED. I AM VERY CONCERNED AS TO THE SAFETY OF THIS MOTORCYCLE NOW. THE TANK'S SWELLING HAS MADE IT SO THE HANDLEBARS DO NOT TURN CORRECTLY. IF THE TANK SWELLS ENOUGH, IT WILL SPLIT OPEN AND I AM CONCERNED THIS WILL HAPPEN WHILE I AM RIDING. *TRRead more
Incident date: Feb 4, 2011
TL* THE CONTACT OWNS A 2006 DUCATI MULTISTRADA 620. THE CONTACT STATED HE RECEIVED NOTIFICATION OF NHTSA CAMPAIGN ID NUMBER: 11V020000 (FUEL SYSTEM, GASOLINE STORAGE:TANK ASSEMBLY). THE CONTACT STATED THAT THE REMEDY OFFERED BY THE MANUFACTURER WAS NOT SUFFICIENT ENOUGH TO CORRECT THE FAILURE. HE STATED THAT THE REMEDY WAS ONLY A TEMPORARY REPAIR TO THE FAILURE AND WOULD NOT ACTUALLY CORRECT THE I
... SSUE ITSELF. THE MANUFACTURER WAS CONTACTED WHO ADVISED THE CONTACT THAT THE REMEDY WAS AN ADEQUATE REPAIR. THE CONTACT HAD NOT EXPERIENCED A FAILURE. THE CURRENT MILEAGE WAS 11,000.Read more
Incident date: Aug 15, 2010
2006 DUCATI SPORT CLASSIC THE FUEL TANK EXPANDED AND NO LONGER REST ON THE FORWARD SUPPORTS. THE TANK ALSO IS DEFORMED AND SMALL BLISTER APPEARED. *LN
Incident date: Mar 16, 2009
TL* THE CONTACT OWNS A 2006 DUCATI MULTISTRADA 620 MOTORCYCLE. THE CONTACT STATED THAT GASOLINE FUEL WAS LEAKING FROM UNDER THE SEAT. THE DEALER WAS CONTACTED AND ADVISED HIM TO REMOVE THE TANK AND BRING IT IN FOR INSPECTION. THE TANK WAS REMOVED AND THE CONTACT DISCOVERED THAT THE FUEL TANK WAS FRACTURED. THE DEALER ADVISED THAT THE WARRANTY FOR THE VEHICLE WAS EXPIRED AND WOULD NOT BE ABLE TO AS
... SIST. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS APPROXIMATELY 5,200.Read more
Incident date: Feb 1, 2011
ETHANOL REACTS WITH THE PLASTIC TANK CAUSING IT TO EXPAND RESULTING IN POSSIBLE GAS LEAKING. WARPING OF THE TANK AND EXPANSION SIGNS ARE VISIBLE. NOTHING HAS BEEN DONE YET TO CORRECT THIS ISSUE. *TR
Incident date: Aug 1, 2010
MY MOTORCYCLE, 2008 DUCATI S2R1000 (NOT AN OPTION ON THE NEXT VEHICLE SELECTOR), HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME, AND IT PRESSES AGAINST THE IGNITION SWITCH. PREVIOUSLY IT OPENED AND CLOSED WITHOUT PROBLEMS, NOW I HAVE TO WEDGE IT AGAINST THE IGNITION SWITCH TO CLOSE IT. THE RUBBER
... MOUNTS NO LONGER SIT ON THE FRAME WHICH MAKES THE GAS TANK SIT TO ONE SIDE. I HAVE NOT SIGNIFICANTLY MODIFIED MY MOTORCYCLE EXCEPT FOR AN AFTERMARKET EXHAUST AND SOME COSMETIC CHANGES. I HAVE MADE NO MODIFICATIONS TO THE FUEL TANK, FUELING SYSTEM OR FUEL PUMP. I TOOK THE BIKE TO THE DEALER WHO SUBMITTED A CLAIM TO DUCATI NORTH AMERICA (THE IMPORTER/FACTORY) AND THEY NOTED THEY WOULD MONITOR IT FOR REPLACE. I AM VERY CONCERNED AS TO THE SAFETY OF THIS MOTORCYCLE NOW. THE TANK'S SWELLING HAS CAUSED IT SIT INCORRECTLY AND HAVE LARGE BUBBLES. IF THE TANK SWELLS ENOUGH, IT WILL SPLIT OPEN AND I AM CONCERNED THIS WILL HAPPEN WHILE I AM RIDING. *TRRead more
Incident date: Jan 10, 2011
RE: NHTSA 11V020 2004 DUCATI MTS 1000. I HAVE RECEIVED THE NOTICE REGARDING THE CAMPAIGN TO REPLACE THE O-RING AT THE FUEL TANK-PUMP FLANGE. PLEASE UNDERSTAND THAT THE O-RING IS NOT THE PROBLEM WITH THESE MOTORCYCLES AND THIS WILL BE A TEMPORARY, BANDAID SOLUTION AT BEST. THE REAL ISSUE IS THE POLYMER FUEL TANKS ARE EXPANDING/WARPING DUE TO ETHANOL IN THE GASOLINE. WHILE MINE HAS NOT LEAKED
... YET, IT IS SHOWING CLEAR SIGNS OF TANK WARPAGE AND EVEN WITH AN IMPROVED O-RING I AM CONCERNED IT WILL EVENTUALLY BEGIN TO LEAK GASOLINE. EVEN BEFORE LEAKS DEVELOP, OWNERS ARE REPORTING PROBLEMS REMOVING AND REINSTALLING THE FUEL TANKS DUE TO EXPANSION AND WARPAGE. THE ONLY REAL FIX TO THIS PROBLEM IS TO HAVE DUCATI AND/OR THEIR FUEL TANK SUPPLIER (ACERBIS) REPLACE THE TANKS WITH UNITS THAT DO NOT REACT WITH GASOLINE CONTAINING ETHANOL. IT IS MY HOPE THAT THE NHTSA CAN BRING THE REQUIRED PRESSURE TO CAUSE THIS TO HAPPEN, THEREBY HELPING TO ENSURE THAT THE OWNERS/RIDERS OF THESE MOTORCYCLES ARE OPERATING SAFE MACHINES. *TRRead more