ENERGY TRANSFER NEDERLAND TERMINAL LLC

hazardous_liquid Incident — — December 29, 2024

Incident Information

Incident DateDecember 29, 2024
OperatorENERGY TRANSFER NEDERLAND TERMINAL LLC
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates29.99755, -93.99271

Cause

CauseCORROSION FAILURE
SubcauseINTERNAL CORROSION

Casualties

Fatalities0
Injuries0

Costs

Property Damage$3,500
Emergency Response$15,000
Other Costs$0

Location Map

Incident Narrative

"ON 12/29/24 AT APPROXIMATELY 10:15 A LEAK WAS DISCOVERED INSIDE OF THE TANK 1546 CONTAINMENT DIKE INVOLVING THE 28-16-INCHG LINE. THE LEAK OCCURRED UNDERGROUND AND ONCE DISCOVERED, THE OPERATORS CHANGED THE LINE UP AND CEASED THE TRANSFER OF OIL THROUGH THE 28-16-INCHG LINE. THE LEAK WAS COMING FROM A PINHOLE. APPROXIMATELY 3 BARRELS OF CRUDE OIL WAS RELEASED. ON SITE CLEANUP CREW REMOVED FREE PRODUCT AND REMOVED CONTAMINATED SOIL FOR REMEDIATION. THE PIPE WAS TEMPORARILY REPAIRED WITH A MECHANICAL CLAMP. THE CAUSE OF THE LEAK IS STILL UNDER INVESTIGATION. A SUPPLEMENTAL REPORT WILL BE SUBMITTED ONCE THE INVESTIGATION IS COMPLETE. SUPPLEMENTAL & FINAL: THE FAILED SECTION WAS CUT OUT AND SENT TO A THIRD-PARTY LAB FOR ANALYSIS. THE METALLURGICAL ANALYSIS DETERMINED THAT THE FAILURE WAS DUE TO AN INTERNAL CORROSION PINHOLE AT THE 6 O'CLOCK POSITION. THE CAUSE OF THE INTERNAL CORROSION WAS MICROBIAL INFLUENCED CORROSION (MIC). TO PREVENT REOCCURRENCE, THE PIPE WAS CUTOUT AND BLINDS INSTALLED AT THE MAIN LINE T AND THE A459 VALVE TO ABANDON THIS SECTION OF DEAD LEG PIPE."

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in