| Date | Product | Reason | Class | Firm |
|---|---|---|---|---|
| Jul 7, 2025 | epoc BGEM BUN Test Card [25pk]. Material Number: 10736515. | Siemens Healthcare Diagnostics Inc. has confirmed that a negative sodium bias may exist in some e... | Class II | Siemens Healthcare Diagnostics Inc |
| Mar 31, 2025 | Stratus CS Acute Care cTNI TestPak.IVD test for cardiac troponin I in heparin... | Siemens Healthcare Diagnostics Inc., is recalling their Stratus CS Acute Care cTNI TestPak, an IV... | Class II | Siemens Healthcare Diagnostics Inc |
| Sep 24, 2024 | epoc BGEM BUN Test Card (25 pk) for the epoc Blood Analysis System, SMN 10736515 | Siemens Healthcare Diagnostics Inc. has confirmed that a negative sodium bias may exist in one lo... | Class II | Siemens Healthcare Diagnostics Inc |
| Oct 19, 2023 | epoc NXS Host Blood Analysis System, Siemens Material Numbers 11413497 (EU), ... | Siemens Healthcare Diagnostics Inc. has confirmed a potential issue that could occur under certai... | Class II | Siemens Healthcare Diagnostics Inc |
| Feb 9, 2022 | Atellica CH Calcium_2 (CA_2), Siemens Material Number 11097644 | Siemens Healthcare Diagnostics Inc. has confirmed the potential for reagent carryover impacting q... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Feb 9, 2022 | Atellica CH Enzymatic Hemoglobin A1c (A1c_E/A1c_H), Siemens Material Number 1... | Siemens Healthcare Diagnostics Inc. has confirmed the potential for reagent carryover impacting q... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Feb 9, 2022 | Atellica CH Lithium_2 (LITH_2), Siemens Material Number 11097637 | Siemens Healthcare Diagnostics Inc. has confirmed the potential for reagent carryover impacting q... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Feb 9, 2022 | Atellica CH Fructosamine (Fruc), Siemens Material Number 11097637 | Siemens Healthcare Diagnostics Inc. has confirmed the potential for reagent carryover impacting q... | Class II | Siemens Healthcare Diagnostics, Inc. |
| Feb 3, 2021 | Dimension Vista HDLC - colorimetric method, lipoproteins - Product Usage: use... | Siemens Healthcare Diagnostics Inc. has confirmed the potential for erroneous results due to disc... | Class II | Siemens Healthcare Diagnostics, Inc. |
| May 15, 2020 | Siemens IMMULITE 2000 XPi Immunoassay System - In vitro Chemistry Analyzer SM... | Flexible tubing connected to the liquid waste bottle can crack during routine customer maintenanc... | Class II | Siemens Healthcare Diagnostics Inc. |
| May 15, 2020 | Siemens IMMULITE 2000 Immunoassay System - In vitro Chemistry Analyzer SMN #1... | Flexible tubing connected to the liquid waste bottle can crack during routine customer maintenanc... | Class II | Siemens Healthcare Diagnostics Inc. |
| May 11, 2016 | Hettich Centrifuge Modules: StreamLAB Centrifuge Module (10372372 or 1044480... | Premature bucket failures | Class II | Siemens Healthcare Diagnostics Inc. |
| Mar 24, 2016 | Dimension Vista 1500 Intelligent Lab System running on software versions V.3.... | Discrepant patient results on Dimension Vista Intelligent Lab Systems. Siemens Healthcare confir... | Class II | Siemens Healthcare Diagnostics Inc. |
| Mar 24, 2016 | Dimension Vista 500 Intelligent Lab System running on software versions V.3.6... | Discrepant patient results on Dimension Vista Intelligent Lab Systems. Siemens Healthcare confir... | Class II | Siemens Healthcare Diagnostics Inc. |
| Nov 10, 2015 | Reagent Management System (RMS) Dimension RxL Max w/o HM Product Usage: T... | Siemens has identified RMS refrigeration compressors that are missing the safety cover on the el... | Class II | Siemens Healthcare Diagnostics Inc. |
| Nov 10, 2015 | Reagent Management System (RMS) Dimension EXL with LM Product Usage: Th... | Siemens has identified RMS refrigeration compressors that are missing the safety cover on the el... | Class II | Siemens Healthcare Diagnostics Inc. |
| Nov 10, 2015 | Reagent Management System (RMS) Dimension RxL Max HM STM Product Usage: ... | Siemens has identified RMS refrigeration compressors that are missing the safety cover on the el... | Class II | Siemens Healthcare Diagnostics Inc. |
| Nov 10, 2015 | Reagent Management System (RMS) Dimension EXL with LM STM Product Usage:... | Siemens has identified RMS refrigeration compressors that are missing the safety cover on the el... | Class II | Siemens Healthcare Diagnostics Inc. |
| Jun 9, 2014 | Coat-A-Count Direct Androstenedione, SMN 10381049, Catalog Number TKAN1. Sie... | The assay is demonstrating a higher frequency of results greater than 10 ng/mL compared to altern... | Class II | Siemens Healthcare Diagnostics Inc. |
| Mar 6, 2013 | Siemens Healthcare Diagnostics Inc. MIcroScan MICroSTREP plus Type 1 B1027-20... | Customer complaint investigation confirmed the issue of false skipped wells and false susceptible... | Class II | Siemens Healthcare Diagnostics, Inc. |