| Date | Product | Reason | Class | Firm |
|---|---|---|---|---|
| Feb 26, 2020 | Synaptive ImageDrive Clinical | A software defect negatively affects the quality of images taken during diagnostic imaging (mammo... | Class II | Synaptive Medical Inc |
| Feb 26, 2020 | ClearCanvas RIS/PACS | A software defect negatively affects the quality of images taken during diagnostic imaging (mammo... | Class II | Synaptive Medical Inc |
| Feb 20, 2020 | TCM4 Base unit, Ref 391-880, UDI:(01)05700693918808, used with the monitor mo... | Reports have been received about the transcutaneous monitoring system display flickering or monit... | Class II | Radiometer Medical ApS |
| Feb 18, 2020 | Firefly Floorsitter, Firefly Splashy Bathseat, Firefly GoTo Seat - Product Us... | The firm received reports of a number of broken latches on the floorsitter. | Class II | James Leckey Design Ltd |
| Feb 18, 2020 | Chemistry QC Premium Plus, Cat. No. LAL4213, GTIN 05055273209006 - Product Us... | The control target and range value for Sodium using the ISE indirect method has been assigned inc... | Class II | Randox Laboratories Ltd. |
| Feb 11, 2020 | Intellijoint Navigation System, Software Application, IJK1 (P/N 000-0547) - P... | During total knee arthroplasty (TKA), the software may incorrectly calculate femur resection depth. | Class II | Intellijoint Surgical, Inc. |
| Feb 3, 2020 | ABL90 FLEX Analyzer, Model Numbers 393-090, with software versions below 3.4M... | The firm received reports of occurrences where the barcode reader misinterpreted the contents of... | Class II | Radiometer Medical ApS |
| Feb 3, 2020 | ABL90 FLEX PLUS Analyzer, Model Number 393-092 - Product Usage: It is intende... | The firm received reports of occurrences where the barcode reader misinterpreted the contents of... | Class II | Radiometer Medical ApS |
| Jan 24, 2020 | LN 3R70-01; software version 2.6.2 and earlier. The software is used with th... | Abbott has identified potential performance issues for the Alinity ci -series Software version 2.... | Class II | Abbott Gmbh & Co. KG |
| Jan 20, 2020 | FlipCutter III Drill | There is potential for the blister tray to be cracked causing the sterile barrier to be compromis... | Class II | T.A.G. MEDICAL PRODUCTS CORPORATION, LTD. |
| Jan 10, 2020 | NUCLISENS¿ Lysis Buffer, IVD, REF 200292, 48X2 ML LYS Manufacturer bioMerie... | Following a customer complaint about colored eluates, leading to invalid results bioMerieux has c... | Class II | BIOMERIEUX - Grenoble |
| Jan 7, 2020 | Cocoon Convective Warming System, Product Code: CWS4000 (110V). | Potential for thermal damage near the power cord connector and Power Entry Module (PEM) due to im... | Class II | Care Essentials Pty., Ltd. |
| Jan 7, 2020 | Cocoon Convective Warming System, Product Code: CWS5000 (110V). | Potential for thermal damage near the power cord connector and Power Entry Module (PEM) due to im... | Class II | Care Essentials Pty., Ltd. |
| Dec 23, 2019 | Neodent Tapered Guided Surgery Drill, Article No. 103.436. UDI 07899878030041... | The laser engraving of the product incorrectly identifies the 4.3 Tapered Guided Surgery Drill as... | Class II | Jjgc Industria E Comercio De Materials Dentario... |
| Dec 19, 2019 | RayStation stand-alone software treatment planning system. Models 4.0, 4.3, 4... | Three issues found: i) The Map ROI options in the ROI list in the Structure Definition module ma... | Class II | RAYSEARCH LABORATORIES AB |
| Dec 19, 2019 | RX Daytona Plus (with ISE/without ISE); Models Nos. RX4040 (w/ISE) and RX4041... | Software version UI2550642107 for the RX Daytona + instrument released to correct the following i... | Class II | Randox Laboratories, Limited |
| Dec 17, 2019 | VitreQ 27G Blunt Needles with luer-lock connector-REF: CN27.D05 GTIN:871921... | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | (1) VitreQ 20G BF Blunt Needles-Ref: BF20.D51 GTIN: 8719214221089 (2) Vitre... | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 27G VFI Cannula-REF: CN27.D03 GTIN: 8719214221461 | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 25G Blunt Needles with luer-lock connector-REF : CN25.D05 GTIN: 8719... | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 23G Silicone Tipped Cannula-CN23.D01 GTIN: 8719214221508 | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 25G Pick Needles-REF: CN25.D04 GTIN: 8719214221607 | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 25G PFC Injection Needle-Ref: MD25.D01 GTIN: 8719214221386 | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | (1)VitreQ 25G BF Blunt Needles-BF25.D51 GITN: 8719214221164 (2) VitreQ 25... | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 25G Silicone Tipped Cannula-REF: CN25.D01 GTIN: 8719214221522 | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 23G PFC Injection Needle- Ref: MD23.D01 GTIN: 8719214221362 | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 20G VFI Cannula-REF: CN20.D03 GTIN: 8719214221485 | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 25G VFI Cannula-REF: CN25.D03 GTIN: 8719214221447 | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 23G VFI Cannula-REF: CN23.D03 GTIN: 8719214221423 | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | (1) VitreQ 23G BF Blunt Needles-BF23.D51 GTIN#: 8719214221126 (2) VitreQ 23... | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 23G Blunt Needles with luer-lock connector-REF: CN23.D05 GTIN: 8719... | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 17, 2019 | VitreQ 23G Pick Needles-REF: CN23.D04 GTIN: 8719214221584 | Microscopic tears of the sterile pouch may compromise sterility | Class II | Vitreq Bv |
| Dec 13, 2019 | Liquid Clinical Chemistry Control, Catalogue Number: LAE4217, Size: 12 x 5 ml | A transcription error has occurred for the Randox Lipase colorimetric value in Liquid Clinical Ch... | Class III | Randox Laboratories Ltd. |
| Dec 12, 2019 | ResMed Stellar, Non-invasive/invasive ventilators, Model: 100, 150 | Combination of software and a component failure may cause audible alarms not to operate properly,... | Class I | ResMed Ltd. |
| Dec 5, 2019 | Stryker T2 Alpha Delta Strike Plate IMN Instruments - part of the IMN Instrum... | Instrument can break at the level of the thread when being exposed to high forces during nail imp... | Class II | Stryker GmbH |
| Nov 28, 2019 | aap Implantate AG, Soft tissue retractor, radiolucent, REF IU 7971-00 | The company has become aware that the soft tissue retractor is not always removed during the sawi... | Class II | AAP Implantate Ag |
| Nov 21, 2019 | ABL90 FLEX PLUS, model no. 393-02; and Spare Part Hemolyzer Units (902-980): ... | The analyzers fail on S7950 (Range +) QC measurements due to the hemolyzer cuvettes, a subcompone... | Class II | Radiometer Medical ApS |
| Nov 21, 2019 | Stryker Pin To Rod Coupling External Fixation System Hoffmann II Compact - P... | Pin To Rod Coupling could not clamp the pin and rod as intended | Class II | Stryker GmbH |
| Nov 21, 2019 | ABL90 FLEX, model no. 393-090; and Spare Part Hemolyzer Units (902-980): R052... | The analyzers fail on S7950 (Range +) QC measurements due to the hemolyzer cuvettes, a subcompone... | Class II | Radiometer Medical ApS |
| Nov 18, 2019 | There is a complaint regarding internal check cable guide mechanism failure f... | A component failure may lead to treatment interruption or incorrect source positioning. | Class II | Nucletron BV |
| Nov 5, 2019 | Dako Autostainer instruments: Autostainer Link 48, Model AS480; Autostainer... | The Autostainer instrument may not have a syringe tray installed which could result in a small vo... | Class II | Dako Denmark A/S |
| Nov 4, 2019 | Apollo, Model Numbers 9784100231, 9784120131, 9784130131 - Product Usage: Apo... | An amendment to the IFU and Service Manual is being issued to prescribe the replacement of the an... | Class II | Villa Sistemi Medicali S.P.A. |
| Nov 4, 2019 | Apollo DRF, Model Number 9784220831 - Product Usage: The remote controlled ta... | An amendment to the IFU and Service Manual is being issued to prescribe the replacement of the an... | Class II | Villa Sistemi Medicali S.P.A. |
| Nov 4, 2019 | Apollo EZ, Model Number 9784152036 - Product Usage: The Apollo EZ remote-cont... | An amendment to the IFU and Service Manual is being issued to prescribe the replacement of the an... | Class II | Villa Sistemi Medicali S.P.A. |
| Nov 4, 2019 | Juno DRF, Model Number 709020 - Product Usage: General. multi-function x-ray ... | An amendment to the IFU and Service Manual is being issued to prescribe the replacement of the an... | Class II | Villa Sistemi Medicali S.P.A. |
| Oct 11, 2019 | MEDICOM SAFEMASK PREMIER PLUS ASTM LEVEL 3 MASKS, Item Code 2042 | Due to an error on the packaging line, some level 2 masks may have been packed in some level 3 ma... | Class II | AMD Medicom Inc. |
| Oct 11, 2019 | MEDICOM SAFEMASK PREMIER PLUS ASTM LEVEL 2 MASKS, Item Code 2040 | Due to an error on the packaging line, some level 2 masks may have been packed in some level 3 ma... | Class II | AMD Medicom Inc. |
| Oct 9, 2019 | Encina HA Femoral Stem, Size 11 Coxa Vara Collared, REF 100-30-011, Ti6AI4V A... | The firm has identified that packaging containing components of the hip replacement range are mi... | Class II | Signature Orthopaedics Europe Ltd |
| Oct 7, 2019 | Optilite Optilite Rheumatoid Factor Kit, Ref: LK151.OPT.A, IVD, Rx Only, UDI... | Assigned Rheumatoid Factor (RF) calibrator value for calibrator component included in kit used to... | Class II | The Binding Site Group, Ltd. |
| Oct 7, 2019 | NRG RF Transseptal Kit; Model No.s : NTK-710-8545, NTK-710-8555, NTK-711-8545... | There is a remote potential for the sterile packaging of the transseptal guiding sheath to be com... | Class II | Baylis Medical Company Inc. |