| Date | Product | Reason | Class | Firm |
|---|---|---|---|---|
| Apr 14, 2023 | VITROS Chemistry Products Calibrator Kit 11 VANC Reagent Generation (GEN) 50 ... | Unavailable to calibrate VITROS Chemistry Products VANC Reagent, Generation (GEN) 50, results in ... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Mar 10, 2023 | VITROS 5600 Integrated System - Refurbished . For use in the in vitro quanti... | MicroTip Pack Opener Assembly Potentially Not Removing or Replacing MicroTip Pack Caps on VITROS¿... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Mar 10, 2023 | VITROS XT 7600 Integrated System - For use in the in vitro quantitative, semi... | MicroTip Pack Opener Assembly Potentially Not Removing or Replacing MicroTip Pack Caps on VITROS¿... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Mar 10, 2023 | VITROS 5600 Integrated System- For use in the in vitro quantitative, semi-qua... | MicroTip Pack Opener Assembly Potentially Not Removing or Replacing MicroTip Pack Caps on VITROS¿... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Mar 9, 2023 | VITROS Immunodiagnostic Products Anti-SARSCoV- 2 Total N Antibody Calibrator... | Incorrect Number of Calibrator Levels (2) Set for the VITROS Immunodiagnostics Products Anti-SARS... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Nov 17, 2022 | VITROS Immunodiagnostic Products Intact PTH Reagent Pack- IVD For the quanti... | Lower than expected iPTH patient and Quality Control (QC) results, reported negatively biased iPT... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Oct 13, 2022 | VITROS Chemistry Products Calibrator Kit 9 -(GEN) 22 of VITROS PHYT Slides F... | Calibration disk Data Release Version (DRV) 6194 to 6200 contain inappropriate calibration mathem... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Jul 19, 2022 | VITROS XT 3400 Chemistry System with Version 3.7.2 and below Product Code: 6... | Performing a system shutdown on VITROS XT 3400 and VITROS XT 7600 Systems may cause a positive or... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Jul 19, 2022 | VITROS XT 7600 Integrated System with Version 3.7.2 and below Product Code: ... | Performing a system shutdown on VITROS XT 3400 and VITROS XT 7600 Systems may cause a positive or... | Class II | Ortho-Clinical Diagnostics, Inc. |
| May 26, 2022 | Anti-SARS-CoV-2 IgG Quantitative Reagent Pack- Intended for use on VITROS¿ E... | On-Analyzer Stability (OAS) time, supported for 6 weeks; not 8 weeks as is currently stated in th... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Dec 10, 2021 | VITROS Chemistry Products VersaTips, Catalog No. 6801715 A VersaTip sales ... | The lot has a shape deformity which may lead to a 16% reduction in the volume of the sample or re... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Nov 22, 2021 | VITROS Immunodiagnostic Products High Sample Diluent A Reagent Pack | Lower than expected results for VITROS¿ Immunodiagnostic Products TSH Reagent Pack when diluted w... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Oct 15, 2021 | VITROS Immunodiagnostic Products Anti-HBc IgM Controls, Product Code 6801427 ... | Ortho Clinical Diagnostics confirmed a complaint that some VITROS Immunodiagnostic Products Anti-... | Class III | Ortho-Clinical Diagnostics, Inc. |
| May 3, 2021 | VITROS CoV2 Ag calibrator (Product Code 6199950) - Product Usage: is a chemi... | Ortho investigated and confirmed the potential for unexpected failed calibration, and condition c... | Class II | Ortho-Clinical Diagnostics, INc. |
| Mar 26, 2021 | VITROS¿ Black Reference Slides CATALOG #: J02316 - Product Usage: The Black R... | Delayed results. Ortho confirmed that two lots of VITROS Black Reference Slides are incorrectly l... | Class II | Ortho-Clinical Diagnostics, INc. |
| Feb 18, 2021 | VITROS Chemistry Products Calibrator Kit 4-(Calibrator values for TIBC only).... | Potential total iron-binding capacity (TIBC) results. The VITROS TIBC performance shift will sta... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Feb 12, 2021 | VITROS Immunodiagnostic Products SARS-CoV-2 Antigen Reagent- In Vitro Diagnos... | VITROS Immunodiagnostic Products SARS-CoV-2 Antigen False Reactive Results Associated When Using ... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Feb 12, 2021 | VITROS SARS-CoV-2 Antigen Reagent Pack - The VITROS Immunodiagnostic Products... | VITROS Immunodiagnostic Products SARS-CoV-2 Antigen False Reactive Results Associated When Using ... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Jan 14, 2021 | VITROS Chemistry Products VersaTips - Product Usage: used to dispense samples... | A deformity affecting a specific lot of VITROS¿ Chemistry Products VersaTips. Deformed VersaTips ... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Nov 20, 2020 | VITROS Automation Solutions, VAS, Catalog Numbers 6844300 & 6844301 - Product... | A software anomaly may cause an aliquoted sample to be labelled as the incorrect sample. This may... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Nov 20, 2020 | enGen Laboratory Automation System, enGen Track System, Catalog Number ENGEN ... | A software anomaly may cause an aliquoted sample to be labelled as the incorrect sample. This may... | Class II | Ortho-Clinical Diagnostics, Inc. |
| Jun 12, 2017 | VITROS Chemistry Products PHYT Slides, REF/CATALOG 829 8671, Rx ONLY, IVD; Or... | The firm identified the potential for biased results to be generated when processing VITROS PHYT ... | Class II | Ortho-Clinical Diagnostics |
| Jan 5, 2017 | VITROS Chemistry Products FS Calibrator 1, REF 680 1873 12 x 3 mL, Rx ONLY, I... | The company received a customer complaint for the inability to calibrate VITROS Chemistry Product... | Class III | Ortho-Clinical Diagnostics |
| Jul 15, 2014 | VITROS¿ Chemistry Products CDM PROM Calibration Data Module Rev. No. 0168 and... | Inability to calibrate or use VITROS NH3 DT Slides, GEN 59 with VITROS Chemistry Products DT Cali... | Class II | Ortho-Clinical Diagnostics |
| Mar 26, 2014 | VITROS Chemistry Products FS Diluent Pack 3, REF 680 1754, 3 x 45 mL, (D1)/15... | Ortho Clinical Diagnostics (OCD) confirmed the potential for lower than expected C-Reactive Prote... | Class II | Ortho-Clinical Diagnostics |
| Mar 26, 2014 | VITROS Chemistry Products Specialty Diluent, REF 855 9825, 6 x 3 mL, IVD --- ... | Ortho Clinical Diagnostics (OCD) confirmed the potential for lower than expected C-Reactive Prote... | Class II | Ortho-Clinical Diagnostics |
| Mar 5, 2014 | VITROS Chemistry Products CRBM Slides, REF 889 2382, IVD -- Ortho-Clinical Di... | The firm identified a potential for biased carbamazepine (CRBM) results to be generated when usin... | Class II | Ortho-Clinical Diagnostics |
| Jan 29, 2014 | VITROS Chemistry Products CDM PROM (Calibration Data Module) No. 0168, Catalo... | Customers were unable to calibrate, or use previously calibrated, VITROS DT CRSC slides (REF/Prod... | Class II | Ortho-Clinical Diagnostics |
| Feb 7, 2013 | VITROS 5,1 FS Chemistry System, Product Code 6801375 and VITROS 5,1 FS Chemis... | Ortho-Clinical Diagnostics, Inc. (OCD) determined that extension springs on some VITROS¿ Systems ... | Class II | Ortho-Clinical Diagnostics |
| Feb 7, 2013 | VITROS 5600 Integrated System, Product Code 6802413. Intended for use in t... | Ortho-Clinical Diagnostics, Inc. (OCD) determined that extension springs on some VITROS¿ Systems ... | Class II | Ortho-Clinical Diagnostics |
| Feb 7, 2013 | VITROS 4600 Chemistry System (VITROS 5,1 FS System family member), Product Co... | Ortho-Clinical Diagnostics, Inc. (OCD) determined that extension springs on some VITROS¿ Systems ... | Class II | Ortho-Clinical Diagnostics |