Codman Certas Programmable Valve In Line Valve with Siphonguard, Unitized Catheter and Accessorie...

FDA Device Recall #Z-0863-2014 — Class II — May 16, 2013

Recall Summary

Recall Number Z-0863-2014
Classification Class II — Moderate risk
Date Initiated May 16, 2013
Status Terminated
Voluntary Voluntary: Firm initiated

Recalling Firm

Firm Codman & Shurtleff, Inc.
Location Raynham, MA
Product Type Devices
Quantity 409 units

Product Description

Codman Certas Programmable Valve In Line Valve with Siphonguard, Unitized Catheter and Accessories Product Code: 82-8806 Product Usage: The CODMAN CERTAS Programmable Valve is an implantable device that provides constant intraventricular pressure and drainage of CSF (cerebrospinal fluid) for the management of hydrocephalus. The valve can be set to a choice of eight opening pressure settings for constant intraventricular perssure drainage of CSF. The CODMAN CERTAS Therapy Management System (TMS) allows the non-invasive reading or adjustment of the valve setting.

Reason for Recall

Codman Certas Programmable Valves used for hydrocephalus may not operate properly

Distribution Pattern

Worldwide Distribution - US Nationwide, Australia, Austria, Belgium, Brazil, Switzerland, Czech Republic, Germany, Spain, Finland, France, Great Britain, Israel, Italy, Netherlands, Norway, Portugal, Russia, Saudi Arabia, Sweden, Slovenia, Slovakia, Turkey, South Africa, and UK.

Lot / Code Information

Lot Codes: CMJCMD CMBC2Z CMDB7C CMJC49 CMBCPR CMCC2T CMDBHC CMLBLZ CMMB14 CNDBCY CNDCV2 CNJCFT CNKBH6 CNLB57 CNMDNL CNNCWD CNPB1Z CPBB3J CPBDBB CPCCM0 CPDBYK

Other Recalls from Codman & Shurtleff, Inc.

Recall # Classification Product Date
Z-1571-2014 Class II MedStream Programmable Infusion Pump, 20 mL, Pr... Nov 10, 2015
Z-1572-2014 Class II MedStream Programmable Infusion Pump, 40 mL, Pr... Nov 10, 2015
Z-1684-2015 Class II CODMAN 3000 Series Refill Set- Huber needles. ... Mar 5, 2015
Z-0091-2015 Class II Codman Lumbar Drainage Catheter Kit II with EDS... Sep 15, 2014
Z-0090-2015 Class II Codman EDS 3 Drainage System (no Ventricular Ca... Sep 15, 2014

Frequently Asked Questions

Contact your healthcare provider and the device manufacturer immediately. Check whether your specific model number and lot number are included in the recall scope. For external devices, stop using the affected product and arrange a replacement. For implanted devices, do not panic — removal is typically not required unless the risk assessment clearly indicates it. Your physician will guide you based on your individual clinical situation and the FDA's recommended actions. Report any adverse effects you may have experienced to FDA MedWatch at 1-800-FDA-1088.

Class I recalls indicate a reasonable probability of serious adverse health consequences or death from the defect. Class II recalls involve products that may cause temporary or medically reversible adverse health consequences, or where serious consequences are remote. Class III recalls cover products not likely to cause any adverse health consequences, typically involving technical regulatory violations. The classification guides urgency — Class I recalls require immediate action, while Class III may simply involve returning a product or acknowledging a labeling change. Always read the specific recall notice for recommended patient actions.

Report problems with medical devices to the FDA through MedWatch at 1-800-FDA-1088 or online at FDA.gov/safety/medwatch. Healthcare facilities are required by law to report device-related serious injuries and deaths. Patients and consumers can also report voluntarily. Include the device name, manufacturer, model number, and a description of the problem and any patient outcome. Reports from patients and clinicians help the FDA identify emerging safety signals and may trigger investigations that lead to recalls of dangerous devices.

What Should You Do?

Stop using this device if you are affected by this recall. Contact your healthcare provider and the manufacturer immediately for guidance. Report adverse events to FDA MedWatch.