Infusomat SPACE PUMP IV SET, 127 IN.-Used with an electrically-powered infusion pump for intrave...

FDA Device Recall #Z-2395-2024 — Class II — June 17, 2024

Recall Summary

Recall Number Z-2395-2024
Classification Class II — Moderate risk
Date Initiated June 17, 2024
Status Ongoing
Voluntary Voluntary: Firm initiated

Recalling Firm

Firm B. Braun Medical, Inc.
Location Allentown, PA
Product Type Devices
Quantity 1872 units

Product Description

Infusomat SPACE PUMP IV SET, 127 IN.-Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/Catalog Number: 480255

Reason for Recall

Potential for the backcheck valve to malfunction, resulting in backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime, resulting in patient injuries of adverse drug reaction and/or product malfunction with loss of medication/blood.

Distribution Pattern

Worldwide distribution - US Nationwide and the country of Canada.

Lot / Code Information

UDI-DI 04046955324804; All Lots Distributed After 06SEP2023.

Other Recalls from B. Braun Medical, Inc.

Recall # Classification Product Date
Z-1021-2025 Class II Design Options COMBINED SPINAL/EPIDURAL TRAY- ... Dec 4, 2024
Z-3144-2024 Class II AET36 ANESTH EXT SET - Anesthesia Extension Set... Aug 8, 2024
Z-2387-2024 Class II Infusomat SPACE PUMP IV SET, 2 CARESITES, ASV-U... Jun 17, 2024
Z-2380-2024 Class II Infusomat 60DROP METRISET PUMP SET, 3 SAFELINE... Jun 17, 2024
Z-2391-2024 Class II Infusomat UNIV. 15 DR PUMP SET, 1.2FIL, 2CRSTE... Jun 17, 2024

Frequently Asked Questions

Contact your healthcare provider and the device manufacturer immediately. Check whether your specific model number and lot number are included in the recall scope. For external devices, stop using the affected product and arrange a replacement. For implanted devices, do not panic — removal is typically not required unless the risk assessment clearly indicates it. Your physician will guide you based on your individual clinical situation and the FDA's recommended actions. Report any adverse effects you may have experienced to FDA MedWatch at 1-800-FDA-1088.

Class I recalls indicate a reasonable probability of serious adverse health consequences or death from the defect. Class II recalls involve products that may cause temporary or medically reversible adverse health consequences, or where serious consequences are remote. Class III recalls cover products not likely to cause any adverse health consequences, typically involving technical regulatory violations. The classification guides urgency — Class I recalls require immediate action, while Class III may simply involve returning a product or acknowledging a labeling change. Always read the specific recall notice for recommended patient actions.

Report problems with medical devices to the FDA through MedWatch at 1-800-FDA-1088 or online at FDA.gov/safety/medwatch. Healthcare facilities are required by law to report device-related serious injuries and deaths. Patients and consumers can also report voluntarily. Include the device name, manufacturer, model number, and a description of the problem and any patient outcome. Reports from patients and clinicians help the FDA identify emerging safety signals and may trigger investigations that lead to recalls of dangerous devices.

What Should You Do?

Stop using this device if you are affected by this recall. Contact your healthcare provider and the manufacturer immediately for guidance. Report adverse events to FDA MedWatch.